Pioneer HEAT PUMP - User Manual

Pioneer HEAT PUMP

Pioneer HEAT PUMP – User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
Page: / 18

Table of Contents:

  • Page 3 – CAUTION
  • Page 4 – INSTALLATION INFORMATION; INSTALLATION ORDER
  • Page 6 – Install the Main Body; INDOOR UNIT INSTALLATION; Installation Location; INSPECTING AND HANDLING THE UNIT; WOODEN CONSTRUCTION
  • Page 7 – STEEL ROOF BEAM STRUCTURE; Install the Indoor Unit.; Unit Dimensions
  • Page 8 – OUTDOOR UNIT INSTALLATION; Outdoor Unit Installation Instructions; Step 1: Select the Installation Location.; The installation area must be dry and well ventilated.; DO NOT; install the unit where it will be; Fix the outdoor unit with anchor bolts (M10); Fix with bolts
  • Page 9 – Table 6.1: Length Specifications of Split; Split Type Outdoor Unit; Outdoor Unit Dimensions
  • Page 10 – Drain Joint Installation; Notes On Drilling H ole In W all; CONNECT THE DRAIN PIPE; Install the Drainpipe of the Indoor Unit
  • Page 11 – Safety Precautions; All field piping must be performed by a licensed; Notes On Pipe Length and Elevation; INSTALL THE CONNECTING PIPE
  • Page 12 – Refrigerant Piping Connection Instructions; Step 3: Flare pipe ends
  • Page 13 – Table 8.2: PIPING EXTENSION BEYOND FLARE FORM; Step 4: Connect the Pipes; NOTE ON MINIMUM BEND RADIUS; Bend the pipe with thumbs; C AUTION
  • Page 14 – Preparations and Precautions; BEFORE PERFORMING EVACUATION; Evacuation Instructions; Manifold Gauge; Air and foreign matter in the refrigerant circuit
  • Page 15 – The Low Pressure Gauge should now show; Remove the charging hose from the service port.; OPEN VALVE STEMS GENTLY; ADDITIONAL REFRIGERANT PER PIPE LENGTH; Connective Pipe; < Standard pipe length Vacuum Pump; Copper Pipe from Indoor Unit
  • Page 16 – Connect the Cable
  • Page 18 – is a registered trademark of Parker Davis HVAC International, Inc.; Fax
Loading the manual

DUCTLESS MINI SPLIT SYSTEM AIR CONDITIONER / HEAT PUMP

FOR FLOOR - CEILING - LOW WALL TYPE INSTALLATIONS

IMPORTANT NOTICE:

Please read this manual carefully before installing
or operating your new air conditioning system.
Be sure to save this manual for your future reference.

Installation
Manual

UAB / UYB Series

(Flex Mount)

UAB: Cooling Only Version
UYB Cooling and Heating Version

Inverter+ and Inverter++ Models

18,000-48,000 BTU/hr

®

®

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 3 - CAUTION

1 installation manual 1. PRECAUTIONS The safty precautions listed here are divided into two categories. After completing installation, make sure that the unit operates properly during the start-up operation. Please instruct the customer on how to operate the unit and keep it properly maintained. Als...

Page 4 - INSTALLATION INFORMATION; INSTALLATION ORDER

2 installation manual To guarantee proper installation, please first read this "installation manual" in its entirety. The air conditioner must be installed by qualified persons. When installing the indoor unit or its tubing, please follow this manual as strictly as possible. If the air condi...

Page 6 - Install the Main Body; INDOOR UNIT INSTALLATION; Installation Location; INSPECTING AND HANDLING THE UNIT; WOODEN CONSTRUCTION

4 installation manual Evaluate the ceiling construction and install using Ø 10 hanging screw bolts. Keep indoor unit, outdoor unit, power supply wiring, and transmission wiring at least 1 meter away from televisions and radios. This is to prevent image interference and noise coming from those electr...

Other Pioneer Models

All Pioneer Other