Page 3 - Contents; Service Call Preparations; ~G8 17; G3 PDP433PU & PDP503PU
Contents Preface 5 Service Call Preparations 6 Hour & P-Count Readings 7-10 Model & System Breakdown 11-12 Optional Accessories 13 Quick Reference 14-22 Power Down G2~G6 15 Shut Down G2~G6 16 Power Down & Shut Down G 7 ~G8 17 Trap Switch Reset G3~G8 18-19 Service Remotes 20-22 G3 PDP433P...
Page 4 - PARTS LIST / QUICK REFERENCE PARTS LIST / ALL MODELS
Contents Continued G5 PDP4350SX & PDP5050SX 59-71 Block Diagrams 60-63 Operation LED’s 64 Shut Down & Power Down 65-71 G6 PDP436PU, PDP506PU, PRO436PU & PRO506PU 72-81 Block Diagrams 74-75 Operation LED’s 76 Shut Down & Power Down 77-80 System Reset 81 G7 PDP4270/71HD, PDP5070/71HD, ...
Page 5 - Safety information; Preface; the
Lead in the solder used in this productis a known reproductive toxicant whichmay cause birth defects or other reproductiveharm. (California Health and Safety CodeSection 25249.5). When servicing this or handling circuitboards and other components whichcontain solder, avoid unprotected skincontact wi...
Page 6 - the HOUR
Recommended preparations for Plasma service Scheduling 1. Request purchase info from customer. Advise that tech will need to see invoice at time of service call. 2. Request model and serial number (use model/system chart). Serial number of panel can be on top, bottom, side edges or by input jacks, a...
Page 7 - “Hour”
SERVICE No: SI-PG06003-A INFORMATION Date: June 26, 2006 POLICY GUIDE To: All Pioneer Electronics Authorized Service Companies From: Quality Assurance and Factory Service Division Subject: Plasma Panel “Hour” & “P- count” meter readings Models: All Plasma models with “Hour” & “P- count” mete...
Page 8 - Warranty Claim Example:
Page 9 - Table 1; Model
(3/4) SI-PG06003-A Table 1 Model Accessing Hours and P count meters Photos/Screen G2 PDP505HD PDP502MX Integrator mode: In standby mode, press "Menu" then "Power" keys within 3 sec. In "MENU" screen ----> Select "OPTION 2" by pressing "DOWN" key 5X ---> ...
Page 10 - guide should be turned off before entering service
(4/4) SI-PG06003-A Table 1 PDP436PU, PDP506PU, PRO436PU, PRO506PU Service factory mode: In standby mode, press and release "Display" key, wait for 4 sec then press and release "Left", "Up", "Left", "Right", "Power" keys within 6 sec. Press "MUTING&...
Page 11 - PLASMA BREAKDOWN MODELS LIST
PLASMA BREAKDOWN MODELS LIST Note: For consumer model : Model # = Media receiver + Panel + Speakers + Table top stand + Wall mount bracket Some models MIGHT not have Media receiver, Speakers, Table Top stand or Wall mount bracket 2. "G" means Generation 3. "Brown" color is new model ...
Page 13 - CL2 RATE; Optional Accessories
Part Number Description Models PDK1000 Table Top Stand PRO800 & 1000HD PDK1014 Table Top Stand PRO1410HD PDK5001 Table Top Stand PDP501MX PWM4211 Flat wall mount bracket For 42" PWM4221 Tilt wall mount bracket For 42" PWM1011 Flat wall mount bracket(Single board) For 50" and 43" ...
Page 15 - RD; BLINKS; model specific sections, or in the product service manual.; Some Generation models have 2 versions with different part
POWER DOWN DIAGNOSIS BY LED DISPLAY BY GENERATION (GENERATION DETERMINED BY 3 RD # IN MODEL PDP50_XXX) RED (LED BLINKS) Panel LED only..Not Media Receiver G2 * In G2 Models the LED does not blink. Lit LED indicates problem area. BLINKS G3 * G4 * G5 G6 1 Y DRIVE MR POWER SUPPLY MR POWER SUPPLY UNUSED...
Page 16 - More detailed help in troubleshooting is available in the
SHUT DOWN DIAGNOSIS BY LED DISPLAY BY GENERATION (GENERATION DETERMINED BY 3 RD # IN MODEL PDP50_XXX) GREEN or BLUE (LED BLINKS) Panel LED Only....Not Media Receiver BLINKS G3 * G4 * G5 G6 1 PANEL MICRO PANEL DRIVE IC COMMUNICATION PANEL DRIVE IC COMMUNICATION HD DIGITAL 2 DIGITAL 11C COMMUNICATION ...
Page 17 - Audio; Blinking; Power Down
Cause RED BLUE Blue 1 SQ IC (Digital Ass'y) Blue 2 Module uCom IIC Communication (Digital or Sensor Ass'y) Blue 3 DIGTAL-RST2 (Digital Ass'y) Blue 4 Panel High or Low Temperature (Sensor Ass'y) Blue 5 Audio Blue 6 Module uCom Communication (Main or Digital Ass'y) Blue 7 Main Ass'y 3Line Serial Commu...
Page 18 - Power Supply Upgrade
Pioneer plasma reference 3rd to 5th generation Integrator mode Factory mode Data backup Trap indication Trap override PDP display w/o media receiver Media receiver kit G3 PU n/a 3 or 4 IC1204 Digital video Red blinks fast Enter factory mode E01 PDP-R03U-SK PRO1000HD PRO800HD 1, locked 3 6 n/a n/a n/...
Page 19 - Trap Switch Reset Procedure
Trap Switch Reset Procedure G-4, G-5, G-6, G-7 , G-8 • Replace media receiver, plasma panel cover, or tape down HDCP trap switch. If the model in question has the TV Guide option, the TV Guide option must be turned off before proceeding. • Using the customer’s remote control enter “ service mode ” b...
Page 20 - REMOTE CONTROL UNIT; RS232 control of PU units requires an interface and system cable.
1 SCREEN SIZE button Press to select the screen size. 2 INPUT buttons Press to select the input . 3 MENU button Press to open and close the on-screen menu. 4 ADJUST ( 5 / ∞ / 3 / 2 ) buttons Use to navigate menu screens and to adjust various settings on the unit.Usage of cursor buttons within operat...
Page 22 - Generation 4 to 8 New Test Remote
• The keys labeled with the same names on the service remote control unit have the same functions as those of the supplied remote control unit. (See "2.3 PANEL FACILITIES.")• For the keys not provided on the supplied remote control unit, see the explanations below: POINT ZOOM Not used with t...
Page 26 - How to release shutdown; Example: How the LED blinks when DIGITAL-IIC communications fail; Shutdown
• Operations : When a microcomputer has detected an abnormality, it turns the power supply to OFF.• LED display : Blinking in green How to release shutdown Press the power key on the remote control to switch the unit back on.(It is not necessary to press the MAIN POWER button to turn off the unit.) ...
Page 27 - DIGITAL VIDEO ASSY
Note: The figures 1 - 4 indicate the number of times the "STANDBY/ON" LED blinks when shutdown occurs in the corresponding route. RXD BUSY REQ_PU TXD CLK *PU_CE TEMP1 DIGITAL VIDEO ASSY THERMAL SENSORASSY SW POWER SUPPLYMODULE MR INTERFACE ASSY AUDIO ASSY MEDIA RECEIVER IC1191 Panel UCOM ext...
Page 28 - of the; Abnormally high temperature; Screen display; Possible causes
1 Panel microcomputer failure 2 DIGITAL-IIC communication failure Shutdown temperature of the sensor Sensor Temp 78 3 Abnormally high temperature Reference Shutdown diagnosis 123456789 101112131415161718 CENT E 1 / 1 3 R V e r s OSD V e r s i o nCV I C V e r s i o n TT X P V e r s i o n i o n MON I ...
Page 30 - Models
30 Models PDP433CMX PDP503CMX PDP4300 PRO800HD & HDI PRO1000HD & HDI
Page 34 - RGB ASSY
13.5V V+12V V+12V IC4004 6.5V -9V IC4110 (24LCS21A) Plug&Play ROM (LT1399CS) 3CH Video Amp. (TC74VHC541) TTL Conv. INPUT1 Input DET. IN1DET WP_SW Time Circuit IC4108 (BA7657F) RGB 2-1 SW STB+5V INPUT1 Component /RGB INPUT2 Component /RGB Terminator SW Audio Input Mute A_MUTE1 EXT_INT VOL IC4103 ...
Page 35 - SLOT CONNECTOR ASSY
IC4803 (EPM3256ATC144-10) PLD for SYNC V+3VD DC/DC Converter IC31(1/2) IC31(2/2) V+2VD IN4DET IN3DET EEPROM Slot State SD RAM 16M SD RAM 16M IC5301 (PD6357B) IC30 IC5602 (MEM29L800TA-90PFIN) Flash ROM 100MHz X'tal VD Shift HWR_DLAY IC5502 (24LC64(I)SN EEP ROM THERMO SENSOR FAN KEY LED RS-232C REM Ma...
Page 36 - FACTORY; SERVICE FACTORY MODE; State Transition Diagram; Factory default screen
Perform the operations of Service Factory mode using the Remote Control Unit provided with the Plasma Display (AXD1459). Service Factory Mode FACTORY (AA5F)Menu (AA8B)KEY LOCK "Menu" key (AA8B) ‘ "Set" key (AA8A) ‘ "STAND BY/ON" key (AA1C) FACTORY (AA5F) STANDBY/ON (AA1C)POWE...
Page 38 - AC power OFF; SHUT DOWN/POWER DOWN DIAGNOSIS BY LED DISPLAY; Shut Down
PDP-433CMX, PDP-433MXE • Operations : When a microcomputer detected abnormality, turn the power supply to OFF.• LED display : Green blinks How to release the shut down state When turn the power supply ON by remote control units, release from the shut down state, and turn the power supply ON.(It is n...
Page 39 - MX AUDIO ASSY
RXD BUSY REQ_PU TXD CLK *PU_CE DEW_DET CN2002 TEMP1 MX AUDIO ASSY RGB ASSY DIGITAL VIDEO ASSY THERMAL SENSORASSY Y DRIVE ASSY SW POWER SUPPLYMODULE SP (L) ASSY SLOT CONNECTORASSY VIDEO SLOT ST1 ASSY OR IC8601 Audio Amp. IC5505 Main UCOM IC5601 Wide UCOM IC5602 Wide UCOM external Flash ROM IC1191 Pan...
Page 42 - Block Diagram
IC5V PSUS SCAN VCC _VH VCC_VH VCC _VH ADD SEL_PULSE IC3201 SENSOR IC1072 CN3201 CN2101 SB1 Y2 CN2001 CN5521 Y1 D13 D5 D4 CN2301 CN5202 TE1 CN1071 Y4 CN5601 CN5602 D1 D2 CN5511 D14 D15 CN5501 D6 CN5502 D7 CN5503 D8 CN5504 D9 LVDS Vofs PD_MUTE Vsus_ADJ. PD RELAY, PD_TRIGGER CN5505 D10 CN5506 D11 CN550...
Page 44 - • Operation statuses indicated by LEDs
• Operation statuses indicated by LEDs Note: "P" stands for panel. : Lit in red : Lit in green : Not lit Standby Power on MR-AC power off P-AC power off MR power-down MR shutdown MR modification P-power-down P-shutdown P-modification Disconnection of the system cable Power management when th...
Page 45 - On Shutdown and power-down; Content
• Identification of locations having abnormality by the number of times the LEDs flash On Shutdown and power-down ∗ If the unit cannot identify which protection circuit was activated, even if a power-down had been detected, the red LED may flash 15 times. Shutdown• Operation: When the microcomputer ...
Page 52 - COMM SLOT ASSY; • Block Diagram
IC7601 SELECTOR IC7608 SELECTOR IC7603 VOLUME IC7610 6dB AMP IC7801 VIDEO AMP IC6255 PD0278A IC6107 PD0278A IC7902 2-1 SEL 6dB AMP IC7803 3-1 SEL IC7611 BUFFER IC8707 IF UCOM IC5003 POWER AMP IC7602 IC7605 IC5002 L/R L/R L/R +L/+R +L V+12V L R -L -L/-R L/R RGB H/V RGB H/V H/V H/V H/V LEG_RLEG_G RGB ...
Page 54 - Slot Protect
Normal Abnormality 0.5s 0.5s 0.5s 3.0s 0.5s 0.5s 0.5s 3.0s LED REDGREEN REDGREEN REDGREEN REDGREEN Standby Power on Power-down Shutdown • Operation statuses indicated by LEDs Note: : Lit in red : Lit in green : Not lit 0.3s 0.3s 0.3s 0.3s REDGREEN Slot Protect Interval 1.5S 54 Red & Green LED's ...
Page 63 - TUNER BOARD ASSY
U8502 D-D CONVERTER IC8506 PM SWITCH IC8903 CC UCOM IC8904 LPF IC2002 VSB DEMOD. IC3001 TUNER UCOM IC7501 DIGITAL VIDEO GATE ARRAY IC6402 AD(MAIN) IC6406 MIX(MAIN) IC6107 MICHAEL (MAIN) IC6602 AD(SUB) IC6255 MICHAEL (SUB) IC6951 ROZ IC7004 CELIA IC7101 MIKE IC7401PANEL LINK TX IC6881 HDMI Rx IC6803 ...
Page 64 - • LED-lighting patterns
Twice * Times Once 0.5s 0.1s 0.5s 0.5s Twice Once 0.5s 0.5s 0.5s 0.5s 3.0s Twice * Times Once 0.5s 0.2s 0.5s 0.5s Twice Once 0.5s 0.5s 0.5s 0.5s 3.0s GREENREDORANGE GREENREDORANGE GREENREDORANGE GREENREDORANGE GREENREDORANGE GREENREDORANGE GREENREDORANGE GREENRED : RED LED ON : GREEN LED ON : ORANGE...
Page 66 - • Diagnosis of the shutdown
No. of times of LED flashing Category Category SD Circuit in operation Defective Assy Reason for shutdown Point to be Checked Possible Defective Part Remarks Green 1 SD1 Communication failure of the panel-drive IC DIGITAL VIDEO Assy Communication failure of IC4 IC4 BLOCK, IC5401 PANEL FLASH BLOCK IC...
Page 69 - MR POWER SUPPLY Unit
1 2 POWER PANEL POWER SUPPLY Unit 43 (50) X DRIVE Assy VSUS UVP X SUS BLOCK IC1203, IC1207 (mask module) 43 (50) Y DRIVE Assy VSUS UVP Y SUS BLOCK IC2303, IC2307 (mask module) 3 SCAN 43 (50) SCAN A, B Assy or Y 43 (50) DRIVE Assy VH UVP SCAN IC SCAN IC VH UVP VH DC/DC IC2401, IC2402, IC2410, L2401 C...
Page 74 - SPEAKERS
IC1555 Driver IC IC1501 LVDS Receiver (PEE002A-K) (PEE002A-K) IC1501 LVDS Receiver CN1501 U1681 IR Receive unit V+ADR5 CN1502 50 ADDRESSASSY HD AUDIO ASSY 50 SCAN B ASSY(UPPER) 50 Y DRIVE ASSY 50 SCAN A ASSY(LOWER) HD IR ASSY Resonance Block IC1554 Driver IC V+ADR4 CLK/LE/HBLK/LBLK R/G/B V+3V STB3.3...
Page 79 - Status of the Unit; Lit in red; LED-lighting patterns
Status of the Unit LED-lighting Pattern Standby, power management Lit in red B R Power on Lit in blue PDP's power not on Flashing in red (at 1-sec intervals) System cable disconnected * Flashing alternately in red and blue (at 1-sec intervals) Waiting for start of rewriting by the microcomputer Wait...
Page 80 - Defective points assumed from the number of times of LED flashing
Defective points assumed from the number of times of LED flashing No. of times of LED flashing Category ∗ 1 Site detected as defective Possible defective points (representative examples) OSD when detected (warning message) LEDs on the panel LEDs on the MR Red Blue Red Blue Blue 1 Red SD Panel drive ...
Page 86 - SIDE KEY ASSY; POD ASSY; TANSHI ASSY
T2 M8 M9 M1 M2 M3 M4 M7 M13 TRAP SW M6 T3 T1 S1 A2 ToAUDIOAssy P8 P9 ToPOWER SUPPLY UNIT D11 To50 DIGITAL Assy SIDE KEY ASSY MAIN ASSY V+3.3V_STB KEY_AD2 KEY_AD1 SW1 VOL + TV_GUIDE CH POWER VOL - CH - INPUT POD ASSY FAN TANSHI ASSY SIDE ASSY M11 C1 C3 M10 C2 M12 M5 RE1 LED/IR ASSY L1 50 LED ASSY V+5...
Page 90 - Notes when visiting for service; On parts replacement; How to locate several items on the Factory menu; count; Quick Reference upon Service Visit
How to enter Integrator mode usingthe supplied remote control unit Release TRAP SW-ERR Notes when visiting for service 1. Notes when disassembling/reassembling 1 Rear case When reassembling the rear case, the screws must be tightened in aspecific order. Be careful not to tighten them in the wrong or...
Page 91 - Structure of Layers in Service Factory Mode; Structure of Layers in Panel Factory Mode 1
Structure of Layers in Service Factory Mode INFORMATION mode 1. VERSION (1) Flash Versions for PANEL system and MAIN system 2. VERSION (2) Flash Versions for DTV system 3. VERSION (3) Flash Versions for CCD ucom and HM 4. MAIN NG SD histories for MAIN (Going Clear model by SET key) 4-1. CLEAR Select...
Page 92 - 0 ADDRESS ASSY; Relay; to; The figures
OR 50 ADDRESS ASSY 50 DIGITAL ASSY POWER SUPPLY UNIT 50X DRIVE ASSY 50Y DRIVE ASSY Relay Control ProtectionCircuit Module Microcomputer PD MUTECircuit YSUSTN_PD YDD_CNV_PD YDRIVE_PD SCN5V_PD SCAN_PD XDRIVE_PD XDD_CNV_PD XSUSTN_PD ADR_PD DRF_B PD_MUTE PS_PD EXT_PD PD PD_TRG_B D21 IC3155 IC3151 D3151 ...
Page 93 - LED Flashing
Prediction of failure symptoms when a PD (power-down) is generated How to distinguish which connector is disconnected LED Flashing Count PD Circuit Checkpoint Main Cause 2 Power supply PD POWER SUPPLY Unit Failure in the POWER SUPPLY Unit 3 SCAN PD 50 SCAN A, B Assy SCAN IC is damaged (short-circuit...
Page 94 - 0 DIGITAL ASSY
V+3.3D V+12V IC4701 IC4402 AV SW MPX IC4901 RGB SW IC5101 M-VDEC Convert 3.3V to 5V IC8301 IC4601 IF ucom CCDucom Thermal Sensor TH8901 IC8201 MULTI IC8302 3.3VRST FAN NG TEMP2 TXD_IFRXD_IFCLK_IFBUSY_IFCE_IFREQ_IF SCL_AV3SDA_AV3 RESET TXD_IC3 RXD_IC3 CLK_IC3 IC3_CE IC3_BUSY IC8409 EEPROM SCL_EP SDA_...
Page 96 - Information on symptoms that do not constitute failure; SUPPLEMENT: On the video setting for HDMI
Information on symptoms that do not constitute failure SUPPLEMENT: On the video setting for HDMI There are three types of HDMI output formats: color difference 4:4:4, color difference 4:2:2, and RGB4:4:4.(The proportions, such as 4:4:4 and 4:2:2, represent those of the amount of data for video signa...
Page 102 - VSIF ASSY; VIDEO Card; MAIN ASSY
CN2201 CN5001 JA5371 INPUT1 JA5372 INPUT2 JA5373 OUTPUT CN7001 INPUT2 CN9011 IC7001 DVI Receiver IC5308 Audio SW +12V IC7006 7V to 5V +7V IC5601 Video SW +5V IC5901 Video SW +5V IC8002 2.5V to 1.5V IC5603 Sync SW +3.3V IC5902 Sync SW +3.3V IC8003 3.3V to 1.5V X8001 X8002 Analog Video signal Control ...
Page 103 - SENB ASSY
IC9501u-COM CN8501 CN9004 CN9005 CN9003 D9003, ALARM Detect IC1001 +3.3V IC1201 +3.3V IC1101 +3.3V FAN (1) B C D J CN1001 CN1201 CN1101 CN9001 IC9503 7V to 3.3V +7V CN9008 +12V +6V CN9006 +7V CN9007 +3.3V CN9012 +2.5V U2401 Remote Control Receiver D2402 LED CN2401 CN8502 F G CN9010 CN9501 IC8105 OSD...
Page 104 - To; Block Diagram PDP607CMX
P7 P5 AC INLET P1 BLOCK PFC +16.5V +16.5V VSUS +6.5V AD2 AD1 AD2 AD1 POWER SUPPLY UNIT Y2 Y SUS -G Y6 Y4 Y5 Y8 BLOCK VOLTAGECONVERTER Y MASK MODULE IC2301 Y MASK MODULE IC2302 Y DK MODULE IC2103 Y DK MODULE IC2151 SCANIC2901 SCANIC2902 SCANIC2903 SCANIC2904 SCANIC2905 SCANIC2906 SCAN PSUS SCANIC2801...
Page 108 - Prediction of failure symptoms when a PD (power-down) is generated; How to distinguish which connector is disconnected
Prediction of failure symptoms when a PD (power-down) is generated LED Flashing Count PD Circuit Checkpoint Main Cause 2 Power supply PD POWER SUPPLY Unit Failure in the POWER SUPPLY Unit 3 SCAN PD 50 SCAN A, B Assy SCAN IC is damaged (short-circuiting between VH and GNDH) 50Y DRIVE Assy Connectors ...
Page 112 - 0 Y DRIVE ASSY
50 ADDRESS SASSY 50 ADDRESS LASSY Sc an IC IC2901 Sc an IC IC2902 Sc an IC IC2903 Sc an IC IC2904 Sc an IC IC2905 Sc an IC IC2906 Sc an IC IC2801 Sc an IC IC2802 Sc an IC IC2803 Sc an IC IC2804 Sc an IC IC2805 Sc an IC IC2806 PSUS Scan Signal Scan Signal PSUS VH IC5V SA1 SB1 VH IC5V VH IC5V VH IC5V ...
Page 114 - Confirmation of the Power-down and Shutdown histories
Notes when visiting for service 1. Notes when disassembling/reassembling 1 Rear case When reassembling the rear case, the screws must be tightened in a specific order. Be careful not to tighten them in the wrong order forcibly. For details, see "Rear Case" in "7. DISASSEMBLY". 2 Atta...
Page 115 - Mode transition in Service Factory mode
Structure of Layers in Service Factory Mode INFORMATION mode 1. VERSION (1) The software versions for each microcomputer 2. VERSION (2) The Flash memory versions for each device 3. VERSION (3) The Flash memory versions for each device 4. MAIN NG The shutdown message ID/event times (Going Clear mode ...
Page 116 - State; LED Pattern
LED Pattern State AC OFF or Main power switch OFF Standby power management Power ON(Screen ON) Power-down Shutdown Trap switch No digital adjustmentdata copied for backup In the process of rewriting the programof the microcomputer Sleep timer During DTV Module software downloading During factoryoper...
Page 117 - ADDRESS ASSY
OR ADDRESS ASSY DIGITAL ASSY POWER SUPPLY UNIT X DRIVE ASSY Y DRIVE ASSY Relay Control ProtectionCircuit Module Microcomputer PD MUTECircuit YSUS PD YDD PD YDRV PD SCN5V PD SCAN PD XDRV PD XDD PD XSUS PD ADR PD DRF SW DRF SW PD MUTE B PS PD EXT PD PD TRG B D21 IC3155 IC3151 D3151 to D3155, D3162 D35...
Page 122 - SERVICE KNOWHOW; See to following page; SUBJECT; How to remove the coating of SCAN IC.
SERVICE KNOWHOW Date: Sep.14, 2004 No.: SKD04003 ( 1/3 ) MODEL No. MODEL No. See to following page SUBJECT 1 How to remove the coating of SCAN IC. PIONEER CORPORATION Memo: SY61 K.MATSUMURA ,MANAGER DP Technical Support Group Classify: Service Support Division [ Required equipment ] tweezers ( Curve...
Page 124 - How to replace the SCAN ICs; nozzle; Work ESD safe; irc
How to replace the SCAN ICs There are two possiblities:- with a nozzle type soldering station - with the CHIPQUICK SMD1 removal kit With nozzle type desoldering station Work ESD safe Solder all pins and check very carefully for dry joints or short c irc u i ts Once the IC is positioned, tip it diago...
Page 125 - after; With Chipquick
Clean site with swab dipped in flux while applying heat. Another way to remove SMDs is with a special solder made by Chip Quik.The solder is an alloy of tin, lead, indium,and bismuth. Bismuth has a very low thermal conductivity. If it is mixed with tin, the melting point is reduced to 65°C.and so it...
Page 127 - ARB
3rd generation 43" PLASMA Quick Reference Chart PDP-433CMX PDP-4300 PRO800HDI PDP-433PU PRO800HD (2) AXY1056 or (7) 59 (7) AXY1059 (7) AXY1059 (2) AXY1056 or (7) 59 (7)AXX1064 (2201-15940) ' (0-3480) ' must check ' (2761-10130) (7) must check (3) New Scan IC S/N 5011 ALL ALL 3811 Service Panel A...
Page 135 - Quick Reference Chart
PDP425CMX Quick Reference Chart PDP-425CMX Service Panel Assy AWU1160 Scan IC SN755870PZT Power Supply Module AXY1127 MD Digital Assy AWV2254 Y Drive Assy AWV2251 X Drive Assy. AWW1067 Main Assy. AWW1100 Audio Assy AWW1105 Address Assy AWV2253 Sus Clamp 1 AWV2250 Sus Clamp 2 AWV2205 FAN Motor AXM105...
Page 136 - Service Panel Assy
6th generation PLASMA Quick Reference Chart PRO506PU PDP506PU PRO436PU PDP436PU Service Panel Assy AWU1134 AWU1135 Power Supply Module AXY1112, AXY1129 Digital Video Assy AWW1028 Y Drive Assy AWV2258 AWV2256 X Drive Assy. AWW1075 AWW1074 HD Audio Assy AWV2203 HD LED Assy AWW1029 HD IR Assy AWW1030 S...
Page 138 - th Generation Plasma Quick Reference Chart
PDP-4270HDPDP-4271HD PRO-940HD PDP-5070PUPDP-5071PU PRO-507PU PDP-6070PUPDP-6071PU PRO-607PU PRO-FHD1 POWER SUPPLY AXY1149AXY1150AXY1153 AXY1153 AXY1149AXY1150AXY1153 AXY1153 AXY1139 AXY1139 AXY1148 SCAN A ASS'Y N/A N/A N/A N/A AWW1186 AWW1186 AWW1229 SCAN B ASS'Y N/A N/A N/A N/A AWW1187 AWW1187 AWW...
Page 139 - NA
7th generation Plasma Quick Reference Chart PRO1140HD PDP5071PU PDP4271PU Service Panel Assy AWU1212 AWU1208 Power Supply Module AXY1135 Digital Assy AWW1139 AWW1138 Y Drive Assy AWW1145 AWV2334 Y Sub Drive AWW1146 NA X Drive Assy. AWW1143 AWW1067 X Sub Drive AWW1144 NA Audio Assy AWW1131 AWW1185 LE...
Page 140 - PROFHD1
PROFHD 1 Quick Reference Chart PROFHD1 Service Panel Assy AWU1198 Power Supply Module AXY1134 FHD Main Assy AWV2292 FHD Digital Assy AWW1115 FHD Y Drive Assy AWV2294 FHD X Drive Assy. AWV2293 FHD Scan A Assy AWW1129, 1229* FHD Scan B Assy AWW1130, 1230* FHD Power Amp Assy AWW1117 FHD Pre Audio Assy ...