Page 3 - CAUTION
1 installation manual 1. PRECAUTIONS The safty precautions listed here are divided into two categories. After completing installation, make sure that the unit operates properly during the start-up operation. Please instruct the customer on how to operate the unit and keep it properly maintained. Als...
Page 4 - INSTALLATION INFORMATION; INSTALLATION ORDER
2 installation manual To guarantee proper installation, please first read this "installation manual" in its entirety. The air conditioner must be installed by qualified persons. When installing the indoor unit or its tubing, please follow this manual as strictly as possible. If the air condi...
Page 6 - Install the Main Body; INDOOR UNIT INSTALLATION; Installation Location; INSPECTING AND HANDLING THE UNIT; WOODEN CONSTRUCTION
4 installation manual Evaluate the ceiling construction and install using Ø 10 hanging screw bolts. Keep indoor unit, outdoor unit, power supply wiring, and transmission wiring at least 1 meter away from televisions and radios. This is to prevent image interference and noise coming from those electr...
Page 7 - STEEL ROOF BEAM STRUCTURE; Install the Indoor Unit.; Unit Dimensions
5 installation manual 3. Wall Mounting Installation 2. Ceiling Installation Fig.5-8 Locate the hanging arm on the hanging screw bolt. (Refer to Fig. 5-9) Screw Nut Washer Hanging Screw Bolt Hanging Arm Fig.5-9 20 ~ 25mm (~1 In) STEEL ROOF BEAM STRUCTURE Hanging Screw Bolt Hanging Bolts Supporting St...
Page 8 - OUTDOOR UNIT INSTALLATION; Outdoor Unit Installation Instructions; Step 1: Select the Installation Location.; The installation area must be dry and well ventilated.; DO NOT; install the unit where it will be; Fix the outdoor unit with anchor bolts (M10); Fix with bolts
6 installation manual 6. OUTDOOR UNIT INSTALLATION Outdoor Unit Installation Instructions Step 1: Select the Installation Location. The outdoor unit should be installed in a location that meets the following requirements: The location is as close to the indoor unit as possible. Ensure that the r...
Page 9 - Table 6.1: Length Specifications of Split; Split Type Outdoor Unit; Outdoor Unit Dimensions
7 installation manual Table 6.1: Length Specifications of Split Type Outdoor Unit (unit: mm/inch) MODEL H D Split Type Outdoor Unit (Refer to Fig. 6.4, 6.5, 6.6, 6.10, and Table 6.1) Fig. 6.6 Fig. 6.5 A B D W H W H Fig. 6.4 Outdoor Unit Dimensions W x H x D Mounting Dimensions Distance A Distance B ...
Page 10 - Drain Joint Installation; Notes On Drilling H ole In W all; CONNECT THE DRAIN PIPE; Install the Drainpipe of the Indoor Unit
8 installation manual M N P ll a w k c a b m o r f ” 2 1 / m c 30 IF USING BRACKETS 10 cm/4” is enough t h g i r n o ” 4 2 / m c 0 6 60 cm / 2 4 ” above t f e l n o ” 2 1 / m c 0 3 n o r f n i ” 8 7 / m c 0 0 2 t Fig. 6.10 Drain Joint Installation Befo re bolting the outdoor unit in place, you must ...
Page 11 - Safety Precautions; All field piping must be performed by a licensed; Notes On Pipe Length and Elevation; INSTALL THE CONNECTING PIPE
9 installation manual Safety Precautions W ARNING • All field piping must be performed by a licensed technician, and must comply with all local and national regulations. • When the air conditioner is installed in a smallroom, measu res must be taken to p revent the refrigerant concentration in the r...
Page 12 - Refrigerant Piping Connection Instructions; Step 3: Flare pipe ends
10 installation manual Refrigerant Piping Connection Instructions CAUTION • The branching pipe must be installed horizontally. An angle of more than 10° may cause malfunction. • DO NOT install the connecting pipe until both indoor and outdoor units have been installed. • Insulate both the gas and li...
Page 13 - Table 8.2: PIPING EXTENSION BEYOND FLARE FORM; Step 4: Connect the Pipes; NOTE ON MINIMUM BEND RADIUS; Bend the pipe with thumbs; C AUTION
11 installation manual 6. Place flaring tool onto the form. 7. Turn the handle of the flaring tool clockwise until the pipe is fully fla red. Flare the pipe in accordancewith the dimensions shown in table 8-2. Table 8.2: PIPING EXTENSION BEYOND FLARE FORM Pipe Gauge Tightening torque Flare dimension (A...
Page 14 - Preparations and Precautions; BEFORE PERFORMING EVACUATION; Evacuation Instructions; Manifold Gauge; Air and foreign matter in the refrigerant circuit
12 installation manual 9. AIR EVACUATION Preparations and Precautions can cause abnormal rises in pressure, which can damage the air conditioner, reduce its efficiency, and cause injury. Use a vacuum pump and manifold gauge to evacuate the line set and the Indoor Unit, removing any non-condensable ga...
Page 15 - The Low Pressure Gauge should now show; Remove the charging hose from the service port.; OPEN VALVE STEMS GENTLY; ADDITIONAL REFRIGERANT PER PIPE LENGTH; Connective Pipe; < Standard pipe length Vacuum Pump; Copper Pipe from Indoor Unit
13 installation manual 3. Open the BLUE (Low Pressure) Valve of ManifoldGauge. Keep the RED (High Pressure) Valve closed. 4. Turn the vacuum pump ON to start evacuating the air from the line set and indoor unit circuits. 5. Run the vacuum pump for at least 15 minutes, or until the Low Pressure Gauge...
Page 16 - Connect the Cable
14 installation manual 10. WIRING Link the connective cables to the terminals, as identified with their respective mached numbers on the terminal block of indoor and outdoor units. Re-install the cover or the protection board. Connect the Cable 10.1 Remove the electric cover of the outdoor unit. If ...
Page 18 - is a registered trademark of Parker Davis HVAC International, Inc.; Fax
16 installation manual QSDLI-016AEN The design and specifications are subject to change without prior notice for productimprovement.Consult with the sales agency or manufacturer for details. 16122700000004 20171209 is a registered trademark of Parker Davis HVAC International, Inc. Parker Davis HVAC ...