Page 4 - CONTENTS
Pelco Manual C1921M-G (1/04) 3 LIST OF TABLES Table Page A Camera Numbers with Switch 7 ON .......................................................................... 7 B Keyboard Addresses ................................................................................................. 8 C VCR Types...
Page 5 - IMPORTANT SAFEGUARDS AND WARNINGS; Only use replacement parts recommended by Pelco.; REGULATORY NOTICES; Reorient or relocate the receiving antenna.
4 Pelco Manual C1921M-G (1/04) IMPORTANT SAFEGUARDS AND WARNINGS Prior to installation and use of this product, the following WARNINGS should be observed. 1. Installation and servicing should only be done by qualified service personnel andconform to all local codes. 2. Unless the unit is specificall...
Page 6 - DESCRIPTION; Modes of Operation; The
Pelco Manual C1921M-G (1/04) 5 DESCRIPTION The KBD4000 Genex ® Multiplexer Keyboard is a full-function keyboard controller for the MX4000 Genex Multiplexer and MX4000SVR Genex Multiplexer Server. This manual covers the KBD4000 keyboard’s operation with both duplex and simplexmodels of the multiplexe...
Page 7 - Connecting Keyboard to Multiplexer; ADDRESS; INSTALLATION; The following parts are supplied:; MODES OF OPERATION; Multiplexer Mode; Proceed to the; Do A; DO A MULTIPLEXER MODE INSTALLATION
6 Pelco Manual C1921M-G (1/04) Figure 1. Connecting Keyboard to Multiplexer 1. Remove the DIP switch cover plate from the rear of the keyboard (refer to Figure 1). 2. Set the switches (refer to Figure 1 for switch locations). ADDRESS Set switches 1, 2, and 3 OFF. This is address 0, which selects the...
Page 8 - For distances over
Pelco Manual C1921M-G (1/04) 7 UNUSED Leave switch 5 OFF. It is not used. TURBO MODE Set switch 6 ON to enable the turbo (extra fast) pan feature or OFF to disable. CAMERA ADDRESS MODE There are two modes for addressing cameras: • Set switch 7 ON if you want to address all cameras consecutively from...
Page 9 - DO A MULTIPLEXER SERVER MODE INSTALLATION; Connecting Keyboards to the Server
8 Pelco Manual C1921M-G (1/04) 1B DO A MULTIPLEXER SERVER MODE INSTALLATION R+ R- T T+ LOCAL KEYBOARD ON 1 2 3 4 5 6 7 ON 1 2 3 4 5 6 7 ON 1 2 3 4 5 6 7 ON 1 2 3 4 5 6 7 1 TX+2 TX-3 12VAC4 12VAC5 GND6 NC7 RX- 1 TX+2 TX-3 12VAC4 12VAC5 GND6 NC7 RX- 1 TX+2 TX-3 12VAC4 12VAC5 GND6 NC7 RX- ADDRESS #2 (R...
Page 10 - LOCAL KEYBOARD PORT CONNECTION; CHECK THESE THINGS; polled; MULTIPLEXER SERVER; can only; Do
Pelco Manual C1921M-G (1/04) 9 3. Replace the cover on the back of the keyboard. 4. Connect the keyboard to the MX4000SVR Multiplexer Server. You can connect up to four keyboards to the server—one to the server’s LOCALKEYBOARD port and three to its REMOTE KEYBOARD(S) port, or all four to the remote....
Page 11 - Camera Setup; Use for moveable cameras controlled by 32-bit extended Coaxitron; Off; Use for fixed cameras.; Programming; section or proceed directly to the; Operating
10 Pelco Manual C1921M-G (1/04) NOTE: If you have a multi- plexer server, you must en-ter the Camera menu fromthe multiplexer’s front panel.Then you can program thecameras from the frontpanel of the multiplexer orfrom the keyboard. 3 SETTING COAXITRON ® CONTROL OF CAMERAS The KBD4000 keyboard provid...
Page 12 - PROGRAMMING; Multiple Camera Display Setup; CONTROLLING THE MULTIPLEXER WITH THE KEYBOARD; IMPORTANT INSTRUCTIONS; PASSWORD; Advanced System Setup; Multiplexer Front Panel
Pelco Manual C1921M-G (1/04) 11 IMPORTANT: The Genex multiplexer lets you work inany of four languages:English (default), French,German, or Spanish. If youneed to change the lan-guage, do so before pro-gramming because youmust reset the multiplexer tofactory defaults before you can change the langua...
Page 13 - MENUS; Menu Tree
12 Pelco Manual C1921M-G (1/04) MENUS Figure 4. Menu Tree Press and hold the VIEW key to switch to the System Setup menu. Enter a camera number and then press and hold the CAM key to change to the Cameramenu. Press and hold the SEQ key to switch to the Sequence menu. Press and hold the LIVE/VCR key ...
Page 14 - Basic System Setup Menu; To program the main basic system parameters:; Time and Date; Set the current time and date. The time uses a 24-hour clock.; Time Display; Title Display shows
Pelco Manual C1921M-G (1/04) 13 SYSTEM SETUP (VIEW KEY) 2/6/8 Hr 2/6/8 Hr MAIN MONITOR VIDEO RESET ACTIVITY DETECTION ALL CH TO *2,6,or 8 Hr 120 Hr 12 Hr 168 Hr 16 Hr 180 Hr 18 Hr 240 Hr 24 Hr 360 Hr 48 Hr 480 Hr 72 Hr 600 Hr 84 Hr 720 Hr 96 Hr 960 Hr HIGH RESOLUTIONREDUCED FLICKER MAIN MONITOR DISP...
Page 16 - Advanced System Setup Menu; To program the advanced main system parameters:; Date Format; Sets the format for displaying the date on the main monitor.; Password
Pelco Manual C1921M-G (1/04) 15 ADVANCED SYSTEM SETUP (VIEW KEY) ALL COLOR*COLOR & B/WRESERVED DATE FORMAT MM-DD-YY PASSWORD DISABLEDFRONT PANEL CONTROL ENABLED MAIN MONITOR DISPLAYRESPONDS TO NONE SPOT MONITOR DISPLAY SEQUENCERESPONDS TO ALARMS AUX MONITOR DISPLAY BLANK RESPONDS TO ACTIVITY CAM...
Page 17 - When programming; Troubleshooting
16 Pelco Manual C1921M-G (1/04) Spot Monitor Display • Select BLANK, SEQUENCE, or TRACK MAIN if you want the spot monitor toswitch to cameras that have alarms or activity detection. Then under RE-SPONDS TO, select ALARMS, ACTIVITY, or ALARMS/ACTIVITY. • Select NONE if you are using the spot for norm...
Page 18 - In; Relay Output
Pelco Manual C1921M-G (1/04) 17 Comm. Type • In polled communication mode (switch 4 off), one multiplexer (any one) must be the master. Only one multiplexer can be master; all others must be slaves. Themaster multiplexer communicates with the slave multiplexers. • In non-polled communication mode (s...
Page 19 - Basic VCR Setting Menu; To program the VCR recording parameters:; Record Speeds
18 Pelco Manual C1921M-G (1/04) RECORD SETUP (LIVE/VCR KEY) ALARM DURATION30 SECONDS1 MINUTE2 MINUTES5 MINUTES10 MINUTES15 MINUTES ENABLED +ENABLED -DISABLED *2, 6, or 8 Hr 24 Hr 96 Hr 240 Hr 12 Hr 48 Hr 120 Hr 360 Hr 16 Hr 72 Hr 168 Hr 480 Hr 18 Hr 84 Hr 180 Hr 600 Hr 720 Hr 960 Hr PELCOROBOTDM ** ...
Page 20 - VCR Types; NTSC
Pelco Manual C1921M-G (1/04) 19 VCR Switch Pulse • ENABLED + means the multiplexer waits for a positive head switching pulse from the VCR. If the multiplexer does not get a pulse from the VCR (because of abroken wire or the VCR does not give a pulse in some modes), it may appear themultiplexer is no...
Page 21 - Custom VCR Setup Menu
20 Pelco Manual C1921M-G (1/04) CUSTOM VCR SETUP (LIVE/VCR KEY) Figure 8. Custom VCR Setup Menu To program the advanced VCR parameters: 1. Press the MAIN MONITOR key. 2. Use the number pad to enter the multiplexer’s address (1-16 if the keyboard isconnected to a multiplexer; 1-8 if the keyboard is c...
Page 22 - Basic Camera Menu; To program a camera input:
Pelco Manual C1921M-G (1/04) 21 CAMERA SETUP (NUMBER AND CAM KEYS) OPENCLOSED VIDEO INPUT TERMINATION 75 OHMALARM INPUT NORMALLY OPENCOAXITRON FORMAT EXTENDED ACTIVITY DETECTION ENABLEDSET DETECTION MASK ENABLEDDISABLED * * ONLY NINE CHARACTERS APPEAR WHEN IN THE 16-CAMERA DISPLAY. EXTENDEDOFFSTANDA...
Page 23 - The Coaxitron
22 Pelco Manual C1921M-G (1/04) (If you play back the tape on the same equipment, any covert picture will still appearblanked. Change the setting to NORMAL to see the picture.) Video Termination • Set to 75 OHM when equipment is connected to the video IN connector only. • Set to LOOP HI-Z when equip...
Page 24 - ACTIVITY DETECTION MASK SETUP; Activity Detection Mask; To program an activity detection mask for a camera:
Pelco Manual C1921M-G (1/04) 23 ACTIVITY DETECTION MASK SETUP ACTIVITY DETECTION MED SENSITIVITY SET ALL CLEAR ALL EXIT TEST ACTIVITY BOX SET ACTIVITY BOX CLEAR LOW SENSITIVITYMED SENSITIVITYHIGH SENSITIVITY Figure 10. Activity Detection Mask Activity detection continually monitors selected camera i...
Page 25 - Camera Sequencing Menu
24 Pelco Manual C1921M-G (1/04) 7. Turn activity boxes on or off (the default is all are on). • To turn on all boxes , use the joystick to choose SET ALL. Press the OPEN key. All boxes contain a symbol (as shown in Figure 10). The multiplexer monitorsactivity in those boxes. • To turn off all boxes ...
Page 26 - HELP MENU; Help Menu; Access the Help menu from any other menu.; ALARM LOG
Pelco Manual C1921M-G (1/04) 25 3. Press the SEQ key for about three seconds. 4. Type the password (3916), if requested. Enter it by pressing each number keyfollowed each time by the CAM key. The Sequence menu appears. The currentlyselected menu item blinks. 5. Use the joystick to move among items o...
Page 27 - MULTIPLE CAMERA DISPLAY SETUP; duplex
26 Pelco Manual C1921M-G (1/04) MULTIPLE CAMERA DISPLAY SETUP You can use the keyboard to configure multiple camera display formats. The LEDs abovethe camera buttons on the multiplexer light to indicate which cameras are being displayed. PROGRAMMING THE PICTURE-IN-PICTURE DISPLAY ( ) You can program...
Page 29 - PROGRAMMING MENU DEFAULTS; Programming Menu Defaults; Menu
28 Pelco Manual C1921M-G (1/04) PROGRAMMING MENU DEFAULTS Table D. Programming Menu Defaults Menu Item Default System Setup Time Display On Title Display On Normal Record Speed 2/6/8 Hr (NTSC/EIA)3 Hr (PAL/CCIR) Alarm Record Speed 2/6/8 Hr (NTSC/EIA)3 Hr (PAL/CCIR) Main Monitor Video (Duplex Only) C...
Page 30 - PROGRAMMING A PRESET; set to TRACK MAIN (refer to the; PROGRAMMING A PATTERN; set to TRACK MAIN (refer to the; Advanced; Move the camera through the pattern.; The LEDs above
Pelco Manual C1921M-G (1/04) 29 PROGRAMMING A PRESET 1. Press the MAIN or SPOT MONITOR key. The green LED over the MAIN or SPOT keylights. When using the MAIN MONITOR, the SPOT MONITOR DISPLAY menu item in theAdvanced System Setup menu must be set to TRACK MAIN (refer to the Advanced System Setup se...
Page 31 - OPERATION
30 Pelco Manual C1921M-G (1/04) 1. LED DISPLAY Displays the address of the multiplexer (from 1-16) with which the keyboard is communicating. 2. LIVE/VCR KEY Selects the source of video to display on the monitor(s). LIVE is live video from the cameras.VCR is recorded video that is played back from a ...
Page 32 - Operation Guide; Press the LIVE/VCR key to select the operation mode.
Pelco Manual C1921M-G (1/04) 31 Table E. Operation Guide Refer to “Functions” in the Index for an alphabetical list of the operations described in Table E. NOTE: References to switch 7 in this table refer to the switch behind the panel on the back of the keyboard. There are two modes for addressing ...
Page 34 - individual
Pelco Manual C1921M-G (1/04) 33 Zoom on a cameraon the mainmonitor. 1. Press the MAIN MONITOR key. The green LED over theMAIN key lights. 2. Select the camera. Addressing by Multiplexer (Switch 7 OFF) a. On the number pad, press the multiplexer’s addressnumber (1-16 if the keyboard is connected to t...
Page 36 - Press the; set to TRACK; multiplexer
Pelco Manual C1921M-G (1/04) 35 1. Follow the steps under “Run a sequence of cameras fromone multiplexer on the main monitor” or “Run a sequence ofcameras from one multiplexer on the spot monitor” to startsequencing the cameras on the main and spot monitors ofindividual multiplexers you want to sequ...
Page 39 - TROUBLESHOOTING
38 Pelco Manual C1921M-G (1/04) TROUBLESHOOTING If you have difficulty operating your system, run through the following checklist to see if youcan solve the problem. 1. Are the keyboard switches set properly? 2. Is the equipment wired properly? 3. Are the menu options in the multiplexer(s) and serve...
Page 40 - immediately; move the; SPECIFICATIONS; ELECTRICAL; watts; KEYBOARD COMMUNICATION; Mechanical; GENERAL
Pelco Manual C1921M-G (1/04) 39 16. If you have a server, each keyboard controls its corresponding monitors. • In SINGLE mode, keyboard 1 controls monitor 1, keyboard 2 controls monitor 2, etc. • In PAIRED mode, keyboard 1 controls monitor 1 (main) and monitor 2 (spot), andkeyboard 3 controls monito...
Page 41 - INDEX; multiplexer 34
40 Pelco Manual C1921M-G (1/04) INDEX A Activity detection 14Activity detection mask setup 23Address setting 9Address switch setting 6, 8Addressing by multiplexer 21, 23, 29Addressing consecutively 21, 23, 29Advanced system setup menu 15Alarm handling 19Alarm input 22Alarm inputs 14Alarm log 25Aux m...
Page 43 - REVISION HISTORY; Date; WARRANTY AND RETURN INFORMATION
42 Pelco Manual C1921M-G (1/04) REVISION HISTORY Manual # Date Comments C1921M 5/98 Preliminary version released for beta evaluation. 7/98 Original version. C1921M-A 12/98 Added Sections 5.0 through 5.4. Added note to section 3.1. Added operations to Table C. C1921M-B 7/99 Added use of keyboard with...