Page 4 - Important Safety Instructions; Use only replacement parts recommended by Pelco.
4 C2473M-C (8/06) Important Safety Instructions Prior to installation and use of this product, the following warnings should be observed. 1. Installation and servicing should be done only by qualified service personnel and conform to all local codes. 2. Use only replacement parts recommended by Pelc...
Page 5 - Description; Series positioning; REQUIRED ACCESSORIES; OPTION 1; Operating software; OPTION 2; Operating software version 1.2 or higher; Software cannot be uploaded to an Esprit system.
C2473M-C (8/06) 5 Description Pelco’s IPS-RDPE-2 data port box is an on-site service tool designed for Spectra III ™ SE, Spectra III, Esprit ® , and ExSite ™ Series positioning systems. The data port box gives on-site access for setup and testing of the positioning system. The IPS-RDPE-2 can be used...
Page 6 - Mounting Instructions; WALL MOUNTING; Mounting to Different Wall Types; Mounting to Wallboard
6 C2473M-C (8/06) Mounting Instructions WALL MOUNTING 1. Open the lid of the IPS-RDPE-2 box. Install two 3/4-inch (1.91 cm) conduit fittings (not supplied). Close the lid of the IPS-RDPE-2 box. 2. Determine the mounting location for the IPS-RDPE-2. 3. Use the IPS-RDPE-2 box as a template and mark th...
Page 7 - POLE MOUNTING; Mounting to Pole with PA402
C2473M-C (8/06) 7 POLE MOUNTING 1. Install the PA402 mount adapter. Refer to the instructions supplied with the adapter. 2. Open the lid of the IPS-RDPE-2 box. Install two 3/4-inch (1.91 cm) conduit fittings (not supplied). Close the lid of the IPS-RDPE-2 box. 3. Attach the IPS-RDPE-2 to the PA402, ...
Page 8 - Cable/Wire Requirements and Connector Locations; Refer to Figure 3 for a layout of the data port box connectors.
8 C2473M-C (8/06) Cable/Wire Requirements and Connector Locations Refer to Figure 3 for a layout of the data port box connectors. It is important to connect all four communication wires from the IPS-RDPE-2 to the Spectra III dome system or ExSite system. It will not be possible to perform software a...
Page 9 - Wiring Diagrams; Coaxitron Controller with Coax Video
C2473M-C (8/06) 9 Wiring Diagrams The IPS-RDPE-2 is designed to work in both coaxial cable and unshielded twisted pair (UTP) video transmission systems. Installation configurations include the following: • Coaxitron Controller with Coax Video • Coaxitron Controller with UTP Video (Passive Receiver O...
Page 14 - The maximum wire gauge allowed for UTP is 16 AWG.
14 C2473M-C (8/06) Figure 9. RS-422 (D or P Protocol) Controller with UTP Video – Point-to-Point Configuration NOTES: • Input power for the IPS-RDPE-2 is 24 VAC only. The maximum wire gauge allowed for power input and output is 12 AWG. • The maximum wire gauge allowed for UTP is 16 AWG. • Refer to t...
Page 17 - Operation; audible alert and return control to the head-end.
C2473M-C (8/06) 17 Operation To view video, control pan/tilt/zoom, or upload revised operating software and language files to a positioning system, do the following: 1. Open the door of the IPS-RDPE-2. Opening the door will automatically disconnect the controller at the head-end and trigger an audib...
Page 18 - Specifications; ELECTRICAL
18 C2473M-C (8/06) Specifications ELECTRICAL Input Voltage 24 VAC Power Consumption 1 VA Does not include power required for positioning system MECHANICAL Construction Aluminum Finish Gray polyester powder coat Cable Entry Two hole plugs will accommodate 3/4-inch (1.91 cm) conduit fittings (not supp...
Page 19 - PRODUCT WARRANTY AND RETURN INFORMATION
The materials used in the manufacture of this document and its components are compliant to the requirements of Directive 2002/95/EC. This equipment contains electrical or electronic components that must be recycled properly to comply with Directive 2002/96/EC of the European Union regarding the disp...