Page 3 - List of Tables
C493M-G (11/97) 3 Contents Important Safeguards and Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Description . . . . . . . . . . . . . . . . . . . . . . . . . . ....
Page 4 - Important Safeguards and Warnings
4 C493M-G (11/97) Important Safeguards and Warnings Prior to installation and use of this product, the following WARNINGS should be observed. 1. Installation and servicing should only be done by qualified service personnel and conform to all local codes. 2. Unless the unit is specifically marked as ...
Page 5 - Description; MODELS
C493M-G (11/97) 5 Description The HS1500 is a high security camera enclosure of medium size designed for indoor “corner mount” installation for such applications as elevators, parking garages, classrooms, detention cells, etc., requiring maximum protection from vandalism in an unobtrusive package. D...
Page 6 - Installation
6 C493M-G (11/97) Installation NOTE: The four (4) fasteners required to secure the HS1500 to a wall (minimum 3/8” diameter recommended) are not supplied. Before installing the HS1500 to a wall, make certain that the mounting surface is able to support the full weight of the enclosure plus the camera...
Page 9 - RECOMMENDED CABLE SIZE
C493M-G (11/97) 9 HB1500/HB1524 HEATER/BLOWER KIT The HB1500/HB1524 heater/blower kits require either 120 VAC or 24 VAC, respectively. The heater provides 80 watts of heat and is thermostatically controlled to turn on at 40°F (4.44°C) and turn off at 60°F (15.56°C). The three-watt fan is on continou...
Page 10 - HEATER/BLOWER KIT INSTALLATION
10 C493M-G (11/97) HEATER/BLOWER KIT INSTALLATION To install the HB1500/HB1524 heater/blower kit, perform the following steps: 1. Remove the cover (Figure 5, item 4). 2. Attach the heater pads to each side of the mounting frame, below the tilt table assembly. 3. Attach the PC board/fan assembly to t...
Page 11 - TAMPER SWITCH INSTALLATION; TAMPER SWITCH WIRING; Maintenance
C493M-G (11/97) 11 TAMPER SWITCH INSTALLATION The HS1500 enclosure comes standard from the factory with a tamper switch installed. Should it become necessary to install a replacement switch, refer to Figure 4 for the correct position of the bracket/switch and perform the following steps: 1. Remove t...
Page 12 - Exploded Assembly Diagram
12 C493M-G (11/97) Exploded Assembly Diagram Figure 5. HS1500 Enclosure Exploded Assembly Diagram Table A. HS1500 Enclosure Exploded Assembly Parts Lists Item No. Qty Description Part Number 123456789 111111111 Bracket, switch, break-inWindow, 10" x 9" x .50" drilled MR5 clear LexanPlate...
Page 13 - Specifications; MECHANICAL
C493M-G (11/97) 13 Specifications MECHANICAL Window 1/2" (12.7 mm) thick impact and abrasion resistant clear Lexan Camera Mounting Adjustable tilt table Maximum Camera/Lens Size Accepts camera/lens combinations (including BNC connector) up to: 8.0" L x 4.0" W x 4.0" H (20.32 cm x 10....