Page 2 - I N S T A L L A T I O N
® I N S T A L L A T I O N FT85041/FR85041 Fiber Transmitter and Receiver Four-Channel Digitally Encoded Video with Bidirectional Data C1645M-A (9/06) C1645M-A.book Page 1 Wednesday, September 13, 2006 3:07 PM
Page 5 - List of Tables
4 C1645M-A (9/06) List of Tables A Data Selection Switch Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 B Data Connector Pin Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 C Troubleshooting with Front-Panel Indicators . ....
Page 6 - Important Safety Instructions; receptacles, and the points where they exit from the apparatus.
C1645M-A (9/06) 5 Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water. 6. Clean only with dry cloth. 7. Do not block any ventilation openings. Install in accordance with the ma...
Page 7 - The product and/or manual may bear the following marks:; RISK OF ELECTRIC SHOCK.
6 C1645M-A (9/06) The product and/or manual may bear the following marks: This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit. This symbol indicates that there are important operating and maintenance instructions in the literature accompanyi...
Page 8 - Regulatory Notices; RADIO AND TELEVISION INTERFERENCE; This Class A digital apparatus complies with Canadian ICES-003.
C1645M-A (9/06) 7 Regulatory Notices This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesire...
Page 9 - Product Overview; DESCRIPTION; Compatible with NTSC, PAL, and SECAM video standards
8 C1645M-A (9/06) Product Overview DESCRIPTION The FT85041/FR85041 fiber transmitter and receiver provide the ability to transmit four unidirectional composite video channels and one bidirectional data channel over one optical fiber (refer to Figure 1). Figure 1. Four-Channel Video FT85041 Transmitt...
Page 10 - MODELS; OPTIONAL ACCESSORIES
C1645M-A (9/06) 9 MODELS The FT85041/FR85041 fiber transmitter and receiver consist of the following series of m odels: Multimode Models:* FT85041MSTR Four-channel fiber optic video transmitter/single-channel data transceiver; multimode, ST connector FR85041MSTR Four-channel fiber optic video receiv...
Page 11 - FRONT PANEL; Front Panel of FT85041 Transmitter
10 C1645M-A (9/06) FRONT PANEL The front panel of the FT85041 transmitter and the FR85041 receiver provides LED indicators that allow you to monitor data activity, signal status, laser status, and operating power. The following sections provide a view of the front panel of the FT 85041 transmitter a...
Page 12 - Troubleshooting
C1645M-A (9/06) 11 FRONT PANEL - FR85041 RECEIVER Figure 3 illustrates the front panel of the FR 85041 receiver. Figure 3. Front Panel of FR85041 Receiver For detailed information about the front-panel indicators, refer to the Troubleshooting section. DATA TX LED DATA RX LED OPTIC FAULT LED, laser s...
Page 13 - REAR PANEL; Figure 4 illustrates the rear panel of the FT 85041 transmitter.
12 C1645M-A (9/06) REAR PANEL Connections to the FT85041 transmitter and the FR85041 receiver are made to the rear panel of the module. The following sections provide a view of the rear panel of the FT 85041 transmitter and the FR85041 receiver. REAR PANEL - FT85041 TRANSMITTER Figure 4 illustrates ...
Page 15 - Installation; PACKAGE CONTENTS; The following items are supplied:; DATA COMMUNICATION SETUP; before
14 C1645M-A (9/06) Installation PACKAGE CONTENTS The following items are supplied: 1 FT85041 transmitter or FR85041 receiver 1 Regulated switching power supply with four plug adapters (North American, Australian, U.K., and European configurations); 100-240 VAC, 50-60 Hz input, 12 VDC output 1 Wall c...
Page 16 - Data Selection Switch Settings; Data Selection
C1645M-A (9/06) 15 With the FT85041 transmitter/FR85041 receiver powered off, turn the Data Selection switch using a screwdriver until the number representing the required data communication is selected. Refer to Table A for Data Selection switch settings. Note the following: • The FT85041 transmitt...
Page 17 - MOUNTING; Data Communication Setup; MOUNTING THE TRANSMITTER/RECEIVER INTO A RACK; Designed to accommodate fiber optic modules as follows:; MOUNTING THE TRANSMITTER/RECEIVER TO A WALL; Mounting the Transmitter/Receiver Using the Wall Clip
16 C1645M-A (9/06) MOUNTING The FT85041 transmitter/FR85041 receiver can be mounted into a rack or can be used as a stan d-alone module. As a stand-alone module, the unit can be placed on a desktop or can be mounted to a wall. NOTE: As a matter of convenience, it is recommended that you set the desi...
Page 18 - two holes on the lower flange of the clip.
C1645M-A (9/06) 17 Mounting the Transmitter/Receiver Using the Wall Clip NOTE: Before mounting the FT85041 transmitter/FR85041 receiver to a wall, ensure that there is adequate space at both ends for viewing the front-panel LEDs and for m aking the various rear-panel cable connections. To attach the...
Page 19 - CONNECTIONS; Power connection
18 C1645M-A (9/06) CONNECTIONS Connections to the FT85041 transmitter and the FR85041 receiver are made on the rear panel of the modules and consist of the following: • Power connection NOTES: – A 12 VDC or 24 VAC power supply can be used to power the transmitter/receiver when used as a stand-alone ...
Page 20 - Data Connector Pin Assignment s; Manchester; Ground
C1645M-A (9/06) 19 Table B. Data Connector Pin Assignment s Pin Number RS-232 RS-422 RS-485 2-Wire RS-485 4-Wire Manchester Bi-Phase 1 — TX+ (Out+) T+/R+ (Out+/In+) TX+ (Out+) — — 2 — TX- (Out-) T-/R- (Out-/In-) TX- (Out-) — — 3 — RX+ (In+) — RX+ (In+) RX+ (In+) (W) RX+ (In+) 4 — RX- (In-) — RX- (In...
Page 21 - RS-232 Data Communication Wiring
20 C1645M-A (9/06) Figure 9. RS-232 Data Communication Wiring R S -232 DATA S ELE C TION RS-232 DATA CONNECTIONS BETWEEN DEVICE A AND FR85041 RECEIVER FR 8 5041 RE C EIVER – DATA C ONNE C TOR 12345 RX 6 TX (DATA IN)(DATA OUT) RXTX (DATA IN)(DATA OUT) 7 8G ND DEVI C E A FT 8 5041 TRAN S MITTER – DATA...
Page 22 - RS-422 Data Communication Wiring
C1645M-A (9/06) 21 Figure 10. RS-422 Data Communication Wiring R S -422 DATA S ELE C TION RS-422 DATA CONNECTIONS BETWEEN DEVICE A AND FR85041 RECEIVER 1 TX+ 2 TX- 3 RX+ 4 RX- (DATA OUT+) (DATA OUT-) (DATA IN+)(DATA IN-) TX+ TX- RX+RX- (DATA OUT+) (DATA OUT-) (DATA IN+)(DATA IN-) 567 8G ND RX+ RX- T...
Page 25 - Manchester Data Communication Wiring
24 C1645M-A (9/06) Figure 13. Manchester Data Communication Wiring MAN C HE S TER MAN C HE S TER DATA S ELE C TION MANCHESTER DATA CONNECTIONS BETWEEN DEVICE A AND FR85041 RECEIVER FR 8 5041 RE C EIVER – DATA C ONNE C TOR 123 (DATA IN+) 4 (DATA IN-) RX+RX- (DATA OUT+)(DATA OUT-) TX+TX- 567 8G ND W* ...
Page 26 - Bi-Phase Data Communication Wiring
C1645M-A (9/06) 25 Figure 14. Bi-Phase Data Communication Wiring BI-PHASE DATA CONNECTIONS BETWEEN DEVICE A AND FR85041 RECEIVER BI-PHASE DATA CONNECTIONS BETWEEN DEVICE B AND FT85041 TRANSMITTER FT 8 5041 TRAN S MITTER – DATA C ONNE C TOR DEVI C E B BI-PHA S E DATA S ELE C TION 1234567 8G ND IN+ IN...
Page 27 - Troubleshooting with Front-Panel Indicators; Indicator Color; Optical Signal Status
26 C1645M-A (9/06) Troubleshooting LED indicators on the front panel of the FT 85041 transmitter/FR85041 receiver allow you to monitor signal status, laser status, data activity, and operating power. Table C provides information about the front-panel indicators and associated troubleshooting guideli...
Page 30 - Specifications; VIDEO
C1645M-A (9/06) 29 Specifications VIDEO Number of Channels 4 Modulation Type Pulse code modulation, 8-bit resolution Video Input (FT85041)/ 1.0 Vp-p, 75 ohms; NTSC, PAL, and SECAM Video Output (FR85041) Bandwidth 6.5 MHz Gain Unity Crosstalk -50 dB typical at 3.58 MHz Differential Gain <1% Differ...
Page 32 - PRODUCT WARRANTY AND RETURN INFORMATION; REVISION HISTORY
PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment. Exceptions to this warranty are as noted below: • Five years on FR/FT/FS Series fiber optic ...