Page 3 - CONTENTS; Section
Pelco Manual C306M-K (4/05) 3 CONTENTS Section Page IMPORTANT SAFETY INSTRUCTIONS ............................................................................ 5 DESCRIPTION ................................................................................................................... 6 MODELS .....
Page 4 - LIST OF ILLUSTRATIONS; Figure; LIST OF TABLES; Table
4 Pelco Manual C306M-K (4/05) LIST OF ILLUSTRATIONS Figure Page 1 Esprit ES3012 System Dimensions Drawing .................................................... 37 LIST OF TABLES Table Page A Switch Settings for SW1 ................................................................................... 32...
Page 5 - IMPORTANT SAFETY INSTRUCTIONS; maximum specified load.
Pelco Manual C306M-K (4/05) 5 IMPORTANT SAFETY INSTRUCTIONS 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. 6. Do not install near any heat ...
Page 6 - DESCRIPTION; MODELS; Basic
6 Pelco Manual C306M-K (4/05) DESCRIPTION The Esprit ® ES3012 Series Integrated Positioning System is available as a basic system or as an ImagePak ® camera and lens package. The basic system integrates a pan and tilt, camera enclosure, and receiver (camera and lens not included). The ES3012 ImagePa...
Page 7 - INSTALLATION; CAMERA AND LENS INSTALLATION
Pelco Manual C306M-K (4/05) 7 INSTALLATION The basic ES3012 system does not include a camera and lens package. Therefore youmust install a camera and lens in the enclosure before mounting the pan/tilt to the base ofthe system. CAMERA AND LENS INSTALLATION (Skip this section if you are installing an ...
Page 9 - PAN AND TILT INSTALLATION; The illustrations show
Pelco Manual C306M-K (4/05) 9 PAN AND TILT INSTALLATION 1 When installing the ES3012 Espritsystem, allow for sufficient clear-ance between the top of the unitand overhead obstructions. This willprevent interference when the en-closure is driven to its maximum el-evation of 40 degrees. 2 Remove the t...
Page 11 - Switch settings
Pelco Manual C306M-K (4/05) 11 8 Turn on the power. If the red LED lights, turn off the power and proceed to the nextstep. If the red LED does not light, refer to the Troubleshooting section. 9 Plug the male Esprit system connector, located on the bottom of the pan and tilt, intothe female Esprit sy...
Page 12 - HOW TO REMOVE THE PAN AND TILT COVER; Remove cover and place to the side.
12 Pelco Manual C306M-K (4/05) TXB SERIES TRANSLATOR BOARD INSTALLATION(OPTIONAL) Pelco’s TXB Series allows controllers from other companies to communicate with the Espritsystem. To install a TXB Series board, remove the left cover of the pan and tilt. Once the cover isremoved, refer to the manual s...
Page 13 - To reinstall the pan and tilt cover, do the following:; HOW TO REINSTALL THE PAN AND TILT COVER
Pelco Manual C306M-K (4/05) 13 To reinstall the pan and tilt cover, do the following: 1. Properly position the cover and slide it into place. The sides of the cover must fit underthe front and back rain guards of the pan and tilt, and the top of the cover must seatagainst the lip of the top gasket. ...
Page 14 - OPERATION; OPERATING NOTES
14 Pelco Manual C306M-K (4/05) OPERATION POWER-UP DISPLAY When the Esprit system is powered up or reset, the selected protocol, revision number, andother information is displayed on the monitor. For example, the screen might show the fol-lowing information: The information displayed depends on the s...
Page 15 - Limit Stops section to program the scan limit stops.; ZONES; Zone Blank in the Programming section for instructions.); PATTERNS; If a preset is set
Pelco Manual C306M-K (4/05) 15 PAN, SCAN, AND TILT SPEEDS Pan and scan speeds are adjustable from 3 to 40 degrees per second through the pro-gramming menu. The tilt speed is one-half of the pan speed. LENS FUNCTIONS Lens zoom, focus, and iris functions are operated from the controller. All lens mode...
Page 16 - PROGRAMMING; ESPRIT MENUS
16 Pelco Manual C306M-K (4/05) PROGRAMMING ESPRIT MENUS To access the main menu, program preset 95. To make selections in the main menu, use the following controls: Joystick: Move up or down to position cursor or to toggle between selections.Iris Open: Enter.Iris Close: Cancel. For detailed programm...
Page 18 - Az/El display is not
18 Pelco Manual C306M-K (4/05) AZ/EL Other Menu Park Time 0 Pan/Scan Spd 7 Power Up Default Pat length 6 min Spd Profile 50 MPH wind <Zone Blank><Az /El /Direction>Exit Az/El/Direction Set Azimuth Zero Az/El Az/El Line Direction Direction Line Disp Duration Exit Az/El programs the horizo...
Page 20 - AZIMUTH ZERO
20 Pelco Manual C306M-K (4/05) AZIMUTH ZERO Azimuth is the pan angle from 0 ° to 359 ° . Azimuth zero is the programmed 0 ° point that is normally set to magnetic north. Once programmed, on-screen pan position (azimuth) andcompass readings are based on the set azimuth zero point. To set azimuth zero...
Page 21 - DIRECTION; For direction to be
Pelco Manual C306M-K (4/05) 21 DIRECTION Direction programs the horizontal display position of the Direction label (N, NW, NE, …). The following settings are available for the Direction label: Off – Label is not displayed.Left – Label is displayed on the left-hand side of the screen.Center – Label i...
Page 22 - DIRECTION LINE; Direction display is
22 Pelco Manual C306M-K (4/05) DIRECTION LINE NOTE: Direction display is not available while you areprogramming or running apattern. Other Menu Park Time 0 Pan/Scan Spd 7 Power Up Default Pat length 6 min Spd Profile 50 MPH wind <Zone Blank><Az /El /Direction>Exit Az/El/Direction Set Azi...
Page 23 - DISPLAY DURATION; Press the Iris Open button to enter the Other menu.; MAIN MENU
Pelco Manual C306M-K (4/05) 23 DISPLAY DURATION Display Duration programs the duration the Az/El, Direction, and Zoom labels are displayedon the monitor. The available settings for display duration include the following: CONSTANT - The label is displayed continuously.2 SECONDS (default) - The label ...
Page 24 - PRESETS
24 Pelco Manual C306M-K (4/05) LIMIT STOPS TURNING LIMIT STOPS ON OR OFF To change the limit stop mode: 1. Program preset 95 (28). The main menu appears. 2. Position the cursor (>) beside Limits. 3. Press the Iris Open button to enter the Limits menu. 4. Position the cursor (>) beside Limit St...
Page 25 - Scan Limit Stops; or; Make sure limit stops are turned ON, and then exit the menu.; LIMIT STOPS MENU; Press the Iris Open button to enter the Limits menu.; CLEAR SCAN LIMIT STOPS
Pelco Manual C306M-K (4/05) 25 Scan Limit Stops When scan limit stops are set, the pan and tilt reverses direction during random, frame, orauto scanning when a limit stop is reached. The manual scan limit stops can be set in oneof two ways: At the controller by programming presets 92 (25) and 93 (26...
Page 26 - If the
26 Pelco Manual C306M-K (4/05) PAN/SCAN SPEED The pan/scan speed is adjustable from 3-40 degrees per second. This occurs in three scanmodes: auto, random, and frame scan. To change the pan/scan speed: 1. Program preset 95 (28). The main menu appears. 2. Position the cursor (>) beside Other. 3. Pr...
Page 28 - SPEED PROFILE; To set the speed profile:
28 Pelco Manual C306M-K (4/05) SPEED PROFILE This feature allows the operator to set the wind speed conditions for the location of thesystem. You can set two wind speed profiles of 50 mph or 90 mph in which the system willremain operational. In both settings, the pan speed will be a maximum of 40 de...
Page 30 - TROUBLESHOOTING; Symptom: Ground loops
30 Pelco Manual C306M-K (4/05) TROUBLESHOOTING Symptom: System does not operate. 1. Check system input voltage. 2. Check for proper positioning of input power select switch for the transformer (ES3012-5models only). 3. The Esprit system is protected by a resettable overcurrent protective device loca...
Page 31 - Symptom: No video or poor video; MAINTENANCE
Pelco Manual C306M-K (4/05) 31 Symptom: No video or poor video 1. Check the video and power connections to the camera. 2. Check for power to the camera from the Esprit system camera power output. 3. Check all coax BNC connectors from the camera to the monitor. 4. Make sure the controller is set for ...
Page 32 - APPENDIX; Esprit will sense and automatically select input from Coaxitron; Switch Settings for SW1; Baud Rate
32 Pelco Manual C306M-K (4/05) APPENDIX NOTE: Esprit will sense and automatically select input from Coaxitron control signals in either the standard or extended mode. Therefore, the DIP switches settings have noeffect on Coaxitron control signals. Table A. Switch Settings for SW1 Baud Rate Switch Se...
Page 33 - Switch Settings for SW2
Pelco Manual C306M-K (4/05) 33 Table B. Switch Settings for SW2 NOTE: The Esprit will sense and automatically select input from Coaxitron control signals in either the standard or extended mode. Therefore, the DIP switches settings have no effect on Coaxitron control signals. Receiver Address Switch...
Page 36 - SPECIFICATIONS; ELECTRICAL
36 Pelco Manual C306M-K (4/05) SPECIFICATIONS ELECTRICAL Input Voltage: 24 or 120/230 VAC, 50/60 Hz; on ES3012-5 models, a switch isinstalled on the transformer module located in the mount base tomake 120 or 230 VAC input voltage selection. Reset featureenabled when power becomes unstable or interru...
Page 37 - Esprit ES3012 System Dimensions Drawing
Pelco Manual C306M-K (4/05) 37 Figure 1. Esprit ES3012 System Dimensions Drawing 13.8 (35.1) 4.1 (10.5) 14.0 (35.5) 4.8 (12.3) 9.1 (23.2) 7.7 (19.7) 6.9 (17.5) 7.9 (20.2) 16.4 (41.7) 5.2 (13.3) NOTE: VALUES IN PARENTHESES ARE CENTIMETERS; ALL OTHERS ARE INCHES. 17.3 (43.9)
Page 38 - REGULATORY NOTICES; Reorient or relocate the receiving antenna.
38 Pelco Manual C306M-K (4/05) REGULATORY NOTICES This equipment has been tested and found to comply with the limits of a Class B digitaldevice, pursuant to part 15 of the FCC rules. These limits are designed to provide reason-able protection against harmful interference in a residential installatio...
Page 39 - REVISION HISTORY; Date; PRODUCT WARRANTY AND RETURN INFORMATION
Pelco Manual C306M-K (4/05) 39 Pelco, the Pelco logo, Camclosure, Esprit, Genex, Legacy, and Spectra are registered trademarks of Pelco. ©Copyright 2005, Pelco. Endura and ExSite are trademarks of Pelco. All rights reserved. Lexan is a registered trademark of the General Electric Company. REVISION H...