Page 2 - ii
20 Pelco Manual C1902M (11/96) TABLE OF CONTENTS Section Page 1.0 IMPORTANT SAFEGUARDS ............................................................................................................. 11.1 FCC INFORMATION .....................................................................................
Page 3 - IMPORTANT SAFEGUARDS
Pelco Manual C1902M (11/96) 1 1.0 IMPORTANT SAFEGUARDS 1. Read Instructions - All the safety and operating instruc-tions should be read before the unit is operated. 2. Retain Instructions - The safety and operating instructionsshould be retained for future reference. 3. Heed Warnings - All warnings ...
Page 4 - CAUTION; For USA customers; Reorient or relocate the receiving antenna.; For United Kingdom customers; Earth; SAFETY PRECAUTIONS
2 Pelco Manual C1902M (11/96) CAUTION RISK OF ELECTRIC SHOCK. DO NOT OPEN 1.1 FCC INFORMATION For USA customers WARNING - This equipment has been tested and found to com-ply with the limits for a Class B digital device, pursuant to Part15 of the FCC Rules. These limits are designed to providereasona...
Page 5 - Figure 1. The CC4600 Series Camera
Pelco Manual C1902M (11/96) 3 2.0 DESCRIPTION The CC4600 series cameras are compact, rugged, full performance general purpose color CCD cameras. Contempo-rary styling and concealed controls allow these cameras to blend naturally into the most modern installation sites.These cameras are 1/3-inch imag...
Page 8 - POWER SUPPLY CONSIDERATIONS; GND
6 Pelco Manual C1902M (11/96) Figure 2. Rear Panels: CC4600-2/-2X and CC4600-3 3.0 POWER SUPPLY CONSIDERATIONS Use only the recommended power supplies. Impropersubstitutions may damage the camera or cause a shockor fire hazard. CC4600-2/2X • The CC3300-2 must always be operated with a 24VAC, Class 2...
Page 10 - Figure 5. Standard Acceptable Lens Dimensions; Lens; C-mount lens CS-mount lens
8 Pelco Manual C1902M (11/96) Figure 5. Standard Acceptable Lens Dimensions 4.0 mm Max Thread(0.16" Max.)For CS Lens 22.4 mm Max.(0.88" Max.) 9.0 mm Max. Thread(0.35" Max)For C Lens Lens 4.0 LENSES 4.1 LENS LIMITS Lenses exceeding the dimensions shown in Figure 5below cannot be used. Whe...
Page 11 - LENS INSTALLATION; Video signal; Information Box
Pelco Manual C1902M (11/96) 9 D Auto Iris Plug Pin-out (Back of Plug) 4 2 1 3 Changing the Plug on an Auto Iris Lens Cable 4.3 LENS INSTALLATION 4.3.1 Auto Iris Install an auto-iris lens as follows:(Refer to Illustration E ) 1. Unscrew lens mount cap. 2. Screw in the lens. NOTE: When attaching a C-m...
Page 12 - CAMERA/LENS GEOMETRY–GENERAL INFORMATION
10 Pelco Manual C1902M (11/96) Incident Light LENS CAMERA (STYLIZED) Iris opening (sometimes referred to as aperture) isdefined by f/stop numbers. The higher the # themore closed the iris is IRIS CCDIMAGER CCD Iris (Electronic Shutter) CCD out-put voltage is electronically sampled andused to adjust ...
Page 14 - Backfocusing; BACKFOCUS ADJUSTMENT
12 Pelco Manual C1902M (11/96) Backfocusing MANUAL IRIS AUTO IRIS A B • Set all other switches on the back of the Camera to theleft (deactivated or OFF), in-c l u d i n g t h e C C D I r i sswitch. • This step is the same as theone for DC SERVO, excptthat the AUTO IRIS VIDEO/DC switch is set to VIDE...
Page 15 - When mounting the lens, loosen; Fitting the Lens
Pelco Manual C1902M (11/96) 13 CAUTION: When mounting the lens, loosen the securing nut on the side andturn the focal length adjustmentto the C position. Mounting a C-mount lens with the adjustmentring in the CS position may dam-age the optical filter. E 1 3 2 4 5 Fitting the Lens
Page 16 - CAMERA INSTALLATION; Connecting the CC4600 Series Cameras
14 Pelco Manual C1902M (11/96) 5.0 CAMERA INSTALLATION ATTENTION: Installation should be per- formed by qualified service personnel only, inaccordance with the National Electrical Codeor equivalent/applicable local codes. When attaching the camera to a ceiling bracket or tri-pod, attach the supplied...
Page 17 - CCD CHARACTERISTICS; Damp or dusty places
Pelco Manual C1902M (11/96) 15 G 3 1 2 4 -90 ° 0 ° +90 ° -90 ° 0 ° +90 ° H Phase Adjustment Vertical Phase 5.3 Vertical Phase (Illustration H ) Vertical phase adjustment is NOT vertical ROLL ad-justment. Each camera is adjusted to the AC zero cross-over point at the factory. Problems arise,however, ...
Page 18 - CARE OF THE UNIT; The camera should
16 Pelco Manual C1902M (11/96) 7.2 CARE OF THE UNIT • Remove dust or dirt on the surface of the lens orCCD with a blower. • Use a soft, dry cloth to clean the body. If it is verydirty, use a cloth dampened with a small quantityof a neutral detergent, then wipe dry. • Avoid using volatile solvents su...
Page 19 - Figure 6. CC4600 Series Dimension Drawing; NOTE: VALUES IN PARENTHESES ARE MILLIMETERS
Pelco Manual C1902M (11/96) 17 9.0 SPECIFICATIONS Image Device: 1/3" interline transfer type CCD Effective Picture Elements: CC4600-2: 768 (horizontal) x 494 (vertical) CC4600-2X/CC4600-3: 752 (horizontal) x 582 (vertical) Lens Mount: C-mount/CS-mount adjustable Signal System: CC4600-2: NTSC/EIA...
Page 20 - WARRANTY AND RETURN INFORMATION; PRODUCT WARRANTY AND RETURN INFORMATION
18 Pelco Manual C1902M (11/96) 10.0 WARRANTY AND RETURN INFORMATION PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material orworkmanship for a period of one year after the date of shipment. Exceptions to this warran...