Notes on Safety Be sure to read the notes on safety before using the unit. 2 Before Using the Unit Notes on Safety • The warning signs and the sample icons shown here are listed for you to use this product safely and correctly as well as to prevent the risk and the damage to you and others from happ...
Page 3 - Product Features; Inhalation possible at various tilt angles.; Cover; Product Contents
Product Features 3 Before Using the Unit Features of the Product / Construction of the Product 1 Newly developed alloy mesh and titanium vibrator Superior mesh technology that improves nebulization efficiency. 2 Pocket-sized unit. As the unit is small enough to be placed in the pocket, you can easil...
Page 5 - AC Adapter
5 Before Using the Unit Names and Functions of the Parts Power Plug* AC Adapter as Optional Supply Main UnitLocking Board AC Adapter Cord Band AC Adapter Connection Stand Do not insert your finger into the Nebulization Port. Nebulization Port Nebulize medication here. Mesh Efficient nebulization is ...
Page 6 - How to Assemble the Main Unit; You must assemble the unit before starting to use it.; Install the Mesh Cap on the Medication Bottle.; - Do not insert the Mesh Cap in the opposite direction.; Install the Medication Bottle to the Main Unit.; - If carrying the unit after the Medication Bottle is installed,
How to Assemble the Main Unit 6 Before Using the Unit How to Assemble the Main Unit First, check how to assemble the unit. You must assemble the unit before starting to use it. You may find the parts slightly hard to assemble because they are made to prevent the medication from leaking. 1 Install th...
Page 7 - How to install the Mouthpiece
7 Before Using the Unit How to Assemble the Main Unit 3 Install the Mask Adapterto the Main Unit. Install the Mouthpiece orthe Inhalation Mask (S) or(L) to the Mask Adapter. If you are not going to use the unit soon after it isassembled. Remove the supplied Mask Adapter and Mouthpiece,or Inhalation ...
Page 8 - How to use the optional AC Adapter; Please note that this AC Adapter is not a battery charger.; How to remove the AC Adapter from the Main Unit; Plug in the power plug of AC Adapter to the electric outlet.; - Push in the AC Adapter until it clicks
How to Prepare the Power Source 8 Correct Use of the Unit How to Prepare the Power Source How to use the optional AC Adapter Please note that this AC Adapter is not a battery charger. 1 Place the Main Unit on the AC AdapterConnection Stand as shown in the Figure. How to remove the AC Adapter from th...
Page 9 - How to Insert Batteries; Remove the Battery Cover.; Put on the Battery Cover.; Battery life and battery replacement; When using alkaline batteries; When using nickel-hydrogen batteries; General advice
9 Correct Use of the Unit How to Prepare the Power Source (1) How to Insert Batteries Batteries are not supplied. Use two commercially available AA alkaline batteries. You can also usenickel-hydrogen batteries (rechargeable batteries). If you use a commercially available battery charger,you can save...
Page 10 - - The maximum capacity of; Install the Mesh Cap.; - If the Mesh Cap is not securely
How to Fill the Medication 10 Correct Use of the Unit How to Fill the Medication 1 Remove the MedicationBottle from the Main Unit. Lift up the Medication Bottle bypushing in the Medication BottleDisengaging Buttons on both sidesand releasing the engagement. 2 Remove the Mesh Cap. Hold the Medication...
Page 11 - - If the Medication Bottle is not; Install the Mask Adapter.
11 Correct Use of the Unit How to Fill the Medication 5 Install the MedicationBottle to the Main Unit. - If the Medication Bottle is not installed correctly, the power will notturn on. - If the Electrodes are extremely stained, the unit will not nebulizenormally. In that case, wipe off thestain. 6 I...
Page 12 - Continuous Nebulization Mode; You can inhale in tandem with respiration.
How to Select the Nebulization Mode 12 Correct Use of the Unit How to Select the Nebulization Mode Continuous Nebulization Mode If you push the Button and immediatelylift your finger away from the Button(within approximately 1 second), the unitnebulizes in Continuous NebulizationMode. If you push th...
Page 13 - - When the optional AC Adapter is used, unplug the power plug from; then push the Button and start inhalation.
How to Inhale 13 Correct Use of the Unit How to Inhale 1 Hold the Main Unit withyour hand and startinhalation in relaxedposture. Slightly slant the Main unit (theside of Button) towards yourself. - If medication or slobber collects on the Mesh, the unit stops nebulization. After removing the Mask Ad...
Page 14 - How to Clean the Unit after Inhalation; Remove the parts from the Main Unit.; - Carefully wash the Mesh when using a medication; Be sure to clean and store the unit after inhalation.; Mesh Cap by boiling to wash off the adhered medication.
How to Clean the Unit after Inhalation 14 Correct Use of the Unit How to Care the Unit after Inhalation 1 Remove the parts from the Main Unit. Remove Inhalation Mask or Mouthpiece, Mask Adapter, andMedication Bottle from the Main Unit. (Refer to Page 9.) 2 Discard the remaining medication. After rem...
Page 15 - Wipe off the stain on the Main Unit.; Wipe off the stain on the Main Unit with gauze.; Dry the parts thoroughly.; How to remove the Mesh Cover
15 Correct Use of the Unit How to Care the Unit after Inhalation 6 After assembling the unit, store it ina clean place. 5 Wipe off the stain on the Main Unit. Wipe off the stain on the Main Unit with gauze. If the Main Unit is heavily stained, lightly moisten gauzewith water and wipe the stain off. ...
Page 16 - - Do not leave the unit soaked in the solution for a long time.; Remove the unit from the solution and rinse it with water.; The following parts can be cleaned by boiling.
How to Disinfect 16 How to Disinfect the Unit How to Disinfect 1 Make a 0.1% diluted solution using benzalkoniumchloride, such as Osvan S and soak the unit for 10minutes. - As for the dilution method, follow the instruction manual of benzalkonium chloride. - Do not leave the unit soaked in the solut...
Page 17 - Install a new Mesh Cap.; - The nebulization rate may vary; How to Replace the Mash Cap
17 How to Disinfect the Unit How to Replace the Mesh Cap 2 Remove the Mesh Capfrom the Medication Bottle 3 Install a new Mesh Cap. - The nebulization rate may vary depending on the type of Mesh Cap you use. You can usually use a Mesh Cap for approximately 1 year (according to the test result ofOMRON...
Page 18 - Unit with a Main Unit Cover.
How to Carry the Unit 18 T roubleshooting T roubleshooting How to Carry the Unit You can carry the with the Mouthpiece orthe Inhalation Mask in the Storage Bag. - When carrying the unit, cover the Main Unit with a Main Unit Cover. - Wash the storage bag when it becomes dirty. - Do not place the AC A...
Page 19 - Troubleshooting
Troubleshooting 19 T roubleshooting T roubleshooting If any trouble occurs while you are using the unit, please check the following first. Replace the batteries with new ones. (Refer to page 9.) Clean the Mesh Cap by boiling toremove the stain. (Refer to Page 16.) - If the trouble cannot be correcte...
Page 20 - Specifications; Option Parts; Omron Mesh Nebulizer
Specifications 20 T roubleshooting Option Parts Parts that can be purchased separately T roubleshooting Specifications / Option Parts Product name: Omron Mesh Nebulizer Model: NE-U22 Power source: 3 VDC (two AA alkaline batteries) 2.4 VDC (two AA nickel-hydrogen batteries) optional AC adapter Power ...