Page 2 - CONTENTS
CONTENTS 1. INSTRUCTIONS FOR SAFE AND PROPER USE 2. POSITIONING OF THE HOB 3. GAS CONNECTION 4. ELECTRICAL CONNECTION 5. ADAPTI ON TO DIFFERENT TYPES OF GAS 6. CLEANING AND MAINTENANCE 7. WARRANTY 2 5,6 8 9 10 12 13 Thank you for choosing our product. We advise you to read this manual carefully. It ...
Page 3 - INTRODUCTI ON
INTRODUCTI ON INSTRUCTIONS FOR SAFE AND PROPER USE This manual is an integral part of the appliance and therefore MUST be kept in its entirety and in an accessible place for the whole working life of the cooking hob. We advise reading this manual and all the instructions therein before using the coo...
Page 4 - play with the hob.
INTRODUCTI ON DO NOT PUT pans without perfectly smooth and flat bottoms on the cooking hob grids. DO NOT USE kitchenware or griddle plates that extend beyond the external perimeter of the hob. THE HOB IS TO BE USED BY ADULTS ONLY. Do not let unsupervised children play with the hob. Replaced applianc...
Page 7 - Clearance above and around domestic cookers Extract
FIGURE 2. Clearance above and around domestic cookers Extract from AS5601 1 Overhead clearances - (Measurement A) Range hoods and exhaust fans shall be installed in accordance with the manufacturer's instructions. However, in no case shall the clearance between the highest part of the hob of the coo...
Page 9 - GAS CONNECTION
GAS CONNECTION This appliances is suitable for installation with Natural Gas or ULPG Refer to page 11 for the relevant burner pressure and appropriate injector sizes. When the appliance is to be connected to Natural Gas then the pressure regulator supplied must be fitted to the gas inlet. A test poi...
Page 10 - ELECTRICAL CONNECTI ON; authority regulations by a qualified electrician.; Overall dimensions: location of gas and electrical connection
ELECTRICAL CONNECTI ON Any electrical writing MUST be carried in compliance with the local electrical authority regulations by a qualified electrician. The appliance has a 3 pin plug attached, to be plugged .into a 240Volt, 50HZ, single phase outlet. WARNING -ALL APPLIANCES MUST BE EARTHED: Omega Ap...
Page 11 - CHANGI NG GAS INJECTORS-CONVERSI ON OF GAS TYPE
CHANGI NG GAS INJECTORS-CONVERSI ON OF GAS TYPE Your cooktop has been manufactured for operation on the gas type marked on the hob/carton. In some cases, it may be necessary to convert to convert the burners for use with another type of gas. 1) Replacement injectors are supplied with the appliance o...
Page 12 - NOMINAL GAS CONSUMPTI ON
FIGURE 4 & 5 NOMINAL GAS CONSUMPTI ON Gas Type; Natural Gas Burner Injector size mm MJ/h - NG (1.00 kPa) Small .90 3.6 Medium 1.15 6.3 Large 1.55 10.8 Wok 1.75 13.2 Fish 1.55 10.8 ULPG Burner Injector size mm MJ/h - NG (2.75 kPa) Small 0.55 4.0 Medium 0.66 6.3 Large 0.85 10.2 Wok 0.98 12.6 Fish ...