It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of its products to the European NewApproach Directives. OMEGA will add the CE mark to every appropriate device upon certification. The information contained in...
Page 9 - SECTION 1. INTRODUCTION; Verify that you receive the following items in the shipping box:; QTY; Set Mounting brackets
1 SECTION 1. INTRODUCTION 1.1 UNPACKING Remove the Packing List and verify that all equipment has been received. If there are any questions about the shipment, use the phone numbers listed on the back cover to contact the Customer Service Department nearest you.Upon receipt of shipment, inspect the ...
Page 10 - SAFETY CONSIDERATIONS
2 1.2 SAFETY CONSIDERATIONS This device is marked with the international caution symbol . It is important to read this manual before installing or commissioning this device as it contains important information relating to Safety and EMC (Electromagnetic Compatibility). This instrument is a panel mou...
Page 11 - SECTION 2. ABOUT THE METER; STANDARD FEATURES
SECTION 2. ABOUT THE METER 2.1 DESCRIPTION The Differential Temperature meter with thermocouple is a value packedindicator/ controller. Four full digits allow for an accurate display of yourtemperature. Select from J, K, T or DIN J thermocouple types. Yourmeter may be a basic indicator or it may inc...
Page 17 - BACK OF THE METER
2.5 BACK OF THE METER Figure 2-2 shows the connector label mounted at the top of the meterhousing. Table 2-2 gives a brief description of each connector at the backof the meter. Figure 2-2 Connector Label (ac power with dc detail) 9
Page 23 - PANEL MOUNTING; Cut a hole in your
3.3 PANEL MOUNTING Figure 3-3 Meter - Exploded VIew 1. Cut a hole in your panel, as shown inFigure 3-3. Forspecificdimensions refer toFigure 3-4. 2. Insert the meter into the hole. Be sure the frontbezel gasket isflush to the panel. 3. Slide on mounting bracket to secure. 4. Proceed to Section 3.4 t...
Page 57 - Power
49 SECTION 13. SPECIFICATIONS (continued) ALARM OUTPUTS 2 Form "C" on/off relays. Configurable for latched and (if applicable) unlatched by software. Max current: 5 AMPS, resistive loadMax voltage: 250 Vac or 30 Vdc ENVIRONMENT ~ ~ AC units 115/230 V~(AC) + 10%, 50/60 Hz7 W max, power consum...
Page 58 - Figure 13-1 Meter Dimensions; SIDE VIEW; CASE
SECTION 13. SPECIFICATIONS (continued) Figure 13-1 Meter Dimensions 50 SIDE VIEW TOP VIEW CASE REAR COVER 96,0 (3.78) 48,0 (1.89) 20,3 (.80) 151,4 (5.96) RETAINER FRONT BEZEL
Page 59 - SECTION 14. FACTORY PRESET VALUES; INPT
MENU ITEM FACTORY PRESET VALUES 51 SECTION 14. FACTORY PRESET VALUES Table 14-1. Factory Preset Values INPT Input Type: K.TC (Type K T/C) DEC.P Decimal Point Position: FFF.F RD.CF Reading Configuration: R.1=F (Fahrenheit) R.2=D (Shows deviation in “RUN” mode) S1.CF Setpoint 1 Configuration: S.1=A (S...
Page 60 - CE APPROVALS INFORMATION; Measurement Category I
52 CE APPROVALS INFORMATION This product conforms to the EMC directive 89/336/EEC amended by 93/68/EEC, and with the European Low Voltage Directive 72/23/EEC. Electrical Safety EN61010-1:2001 Safety requirements for electrical equipment for measurement, control andlaboratory. Double InsulationPollut...
Page 61 - RETURN REQUESTS/INQUIRIES
WARRANTY/ DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of one (1) year from the date of purchase. In addition to OMEGA’s standard warranty period, OMEGA Engineering will extend the warranty period for four (4) additional years ...