Omega CNI32 - Manual

Omega CNI32

Omega CNI32 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
53 Page 53
54 Page 54
55 Page 55
56 Page 56
57 Page 57
58 Page 58
59 Page 59
60 Page 60
61 Page 61
62 Page 62
63 Page 63
64 Page 64
65 Page 65
66 Page 66
67 Page 67
68 Page 68
69 Page 69
70 Page 70
71 Page 71
72 Page 72
Page: / 72

Table of Contents:

  • Page 2 – OMEGAnet
  • Page 3 – TABLE OF CONTENTS
  • Page 5 – NOTES, WARNINGS and CAUTIONS; Provides you with information that is important to successfully
  • Page 6 – INTRODUCTION
  • Page 7 – Safety Considerations; Do not expose this instrument to rain or moisture.; EMC Considerations; Whenever EMC is an issue, always use shielded cables.
  • Page 9 – SETUP; Figure 2.1 Front Panel Display; PV; * See Part 3 Operation: Configuration Mode
  • Page 10 – POWER; OUTPUT 2; Based on one of the following models:; OPTION; Based on one of the following models:
  • Page 11 – Electrical Installation; Do not connect power to your device until you have completed all; Figure 2.4 Main Power Connections; FUSEConnector; Power
  • Page 12 – Figure 2.5 Thermocouple Wiring Hookup; TYPEInput Connector; Table 2.4 TC Wire Color Chart
  • Page 13 – 00 ohm Wiring Hookup
  • Page 14 – is 14 kΩ for 10 V process input.
  • Page 17 – To change the color of the upper display, see; Use a jumper for GREEN or RED, never leave S1 open.; Figure 2.14 i/8 D Location of S1 and Selectable Jumper Positions
  • Page 18 – OPERATION: Configuration Mode; Turning your Controller On for the First Time; RST; Table 3.1 Button Function in Configuration Mode; will reset the instrument prior to resuming Run Mode.
  • Page 20 – ERRo
  • Page 22 – Figure 3.2 Flow Chart for Configuration Menu; Enter Configuration Menu:; CNFG; Figure 3.3 Flow Chart for Input Type Menu
  • Page 24 – ENTER INPUT TYPE MENU:
  • Page 25 – Figure 3.4 Flow Chart for Reading Configuration Menu
  • Page 27 – Reading Configuration (If Process was selected)
  • Page 28 – Table 3.2 Conversion Table; RANGE
  • Page 29 – Figure 3.5 Flow Chart for Alarm 1
  • Page 32 – ALARM 1 LOW VALUE SUBMENU:; ALARM 1 HI VALUE SUBMENU:
  • Page 33 – ENTER ANALOG OUTPUT MENU:
  • Page 36 – Alarm must be DISABLED if Ramp is ENABLED.; Figure 3.7 Flow Chart for Alarm 2; DSBL; Disabled; LOOP; Enabled
  • Page 37 – Figure 3.8 Flow Chart for Loop Break Time/Field Calibration; ENTER LOOP BREAK TIME MENU:; Loop Break; is completed successfully, otherwise; LOOP BREAK TIME VALUE SUBMENU:; Loop Break Time Value; allows the user to determine the time interval in MM:SS (from; READING ADJUST SUBMENU:; advances to
  • Page 38 – Reading Offset Adjust; allows the user to fine tune a minor error of the transducer,; SETPOINT DEVIATION ENABLE/DISABLE SUBMENU:; ENBL; Submenu, if “enabled”, allows changes to Setpoint 1 to be made; THERMOCOUPLE FIELD CALIBRATION SUBMENU:; only
  • Page 39 – , Output 1 is automatically; Figure 3.9 Flow Chart for Output 1; is required that you put
  • Page 41 – PID
  • Page 45 – DAMPING FACTOR SUBMENU:; DEAD
  • Page 46 – Figure 3.10 Flow Chart for Output 2; CONTROL TYPE SUBMENU:
  • Page 49 – Figure 3.11 Flow Chart for Ramp and Soak; ENTER RAMP AND SOAK MENU:
  • Page 51 – Figure 3.12 Flow Chart for ID Code
  • Page 52 – FULL SECURITY LEVEL SUBMENU:
  • Page 53 – . For complete instructions on; Figure 3.13 Flow Chart for Communication Option
  • Page 55 – MODBUS PROTOCOL SUBMENU:
  • Page 58 – TRANSMIT TIME INTERVAL SUBMENU:
  • Page 59 – Figure 3.14 Flow Chart for Display Color Selection; ENTER DISPLAY COLOR SELECTION MENU:
  • Page 61 – The instrument automatically resets after the last menu of
  • Page 62 – SPECIFICATIONS; Dual slope
  • Page 64 – No CE compliance above 60 Hz
  • Page 65 – Table 4.1 Input Properties; TC
  • Page 66 – FACTORY PRESET VALUES; Table 5.1 Factory preset value; MENU ITEMS
  • Page 68 – CE APPROVALS INFORMATION; Isolated RS232 to Inputs:; Measurement Category I; *Units configured for external low power dc voltage, 12-36Vdc
  • Page 69 – NOTES
  • Page 71 – RETURN REQUESTS/INQUIRIES
Loading the manual

User’s Guide

USA

MADE IN

www.omega.com

e-mail: [email protected]

iSeries info:

www.omega.com/specs/iseries

Temperature & Process Controller Manual

CNi8, CNi8C, CNi8DH, CNi8DV,

CNi16, CNi16D, CNi32

Shop on line at

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - OMEGAnet

It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE markto every appropriate device upon certification. The information contained in...

Page 3 - TABLE OF CONTENTS

TABLE OF CONTENTS Part 1: Introduction ............................................................................................ 2 1.1 Description ................................................................................. 2 1.2 Safety Considerations ...........................................

Page 5 - NOTES, WARNINGS and CAUTIONS; Provides you with information that is important to successfully

NOTES, WARNINGS and CAUTIONS Information that is especially important to note is identified by following labels: • NOTE • WARNING or CAUTION• IMPORTANT• TIP NOTE: Provides you with information that is important to successfully setup and use the Programmable Digital Meter. CAUTION or WARNING: Tells y...