2 CONTENTS 1. OVERVIEW.................................................................................................... 3 1.1 Overview ............................................................................................... 3 1.2 Included Parts ................................................
Page 5 - SYSTEM CONFIGURATION; System Configuration
4 2. SYSTEM CONFIGURATION 2.1 System Configuration This section describes the system configuration and restrictions when the QA6ADP is used. (1) The QA6ADP+A5 B/A6 B is only applicable for the High Performance model QCPU (Q02CPU, Q02HCPU, Q06HCPU, Q12HCPU, and Q25HCPU). (2) Mount the Q5 B/Q6 B, QA6 ...
Page 6 - Configuration Device List
5 2.2 Configuration Device List (1) Extension base unit mountable on the QA6ADP The following shows extension base units that can be mounted on the QA6ADP. Product name Model Remarks Extension base unit (Power supply module not mounting type) A52B, A55B, A58B, A55B-UL, A58B-UL ---- Extension base un...
Page 8 - General Specifications; This section describes general specifications of the QA6ADP.
7 3. SPECIFICATIONS 3.1 General Specifications This section describes general specifications of the QA6ADP. Item Specifications Operating ambient temperature 0 to 55 Storage ambient temperature -20 to 75 Operating ambient humidity 10 to 90 % RH, No-condensing Storage ambient humidity 10 to 90 % RH, ...
Page 9 - Performance Specifications; Item Specifications
8 3.2 Performance Specifications This section describes performance specifications of the QA6ADP. Item Specifications 5VDC internal current consumption 110 mA External dimensions *1 130 mm (5.11 inch) (H) 73.5 mm (2.89 inch) (W) 74 (2.91 inch) mm (D) Weight 0.2 kg Adapter mounting screw (M3) torque ...
Page 10 - PART NAMES AND SETTING; This section describes part names of the QA6ADP.
9 4. PART NAMES AND SETTING 4.1 Part Names This section describes part names of the QA6ADP. 1) 6) 2) 3) 4) 3) 7) 9) 8) 5) No. Name Application 1) Extension cable connector Connector for sending/receiving signals to the main base unit or the other extension base unit and connecting an extension cable...
Page 11 - Extension Stage Number Setting; POINT
10 4.2 Extension Stage Number Setting Set the number of extension stages to both the QA6ADP and the extension base unit. The same stage number should be set to both the stage number setting connector of the extension base unit and that of the QA6ADP. POINT Set any number of 1 to 7 which matches to t...
Page 12 - LOADING AND INSTALLATION
11 5. LOADING AND INSTALLATION 5.1 Mounting/Removal of QA6ADP (1) Mounting of the QA6ADP The following shows procedures for mounting the QA6ADP on the extension base unit. Mount a board fixing screw of the QA6ADP to a screw hole (A) at top left of the board. Connect an extension base unit mounting c...
Page 14 - Connection/Disconnection of Extension Cable; (1) Precautions for handling an extension cable; The following shows extension cables connectable to the QA6ADP.
13 5.2 Connection/Disconnection of Extension Cable (1) Precautions for handling an extension cable • Do not step on an extension cable. • When laying an extension cable, the minimum bend radius of the cable should be 55 mm (2.17 inch) or more. If it is less than 55 mm (2.17 inch), malfunction may oc...
Page 15 - To connect an extension cable to the QA6ADP, remove a sticker on the; To connect an extension cable to the OUT side connector of the
14 • To connect an extension cable to the QA6ADP, remove a sticker on the IN side connector. Sticker QA6ADP Extension base unit Base cover IN side • To connect an extension cable to the OUT side connector of the QA6ADP, remove the portion (lid) under the characters "OUT" by tools such as a f...
Page 16 - Make sure to tighten fixing screws of the extension cable
15 • Hold the connector part of an extension cable when connecting the extension cable to the QA6ADP. QA6ADP Extension base unit Connector Extension cable • Make sure to tighten fixing screws of the extension cable connector after connecting the extension cable. (Tightening torque: 0.20 N m) QA6ADP ...
Page 17 - PRECAUTION FOR USING QA6ADP; Current Consumption of QA6ADP; Symbol Description; I I0 I2 I3 IA 3
16 6. PRECAUTION FOR USING QA6ADP 6.1 Current Consumption of QA6ADP Since 5VDC is supplied to the QA6ADP from the power supply module of the main base unit, take the current consumption of the QA6ADP into consideration when selecting the power supply module for the main base unit. n: Quantity of QA6...
Page 18 - Voltage Drop of Extension Cable; Model; mounted, refer to the manual for the module to be mounted.; V V1 V2 V3 R1 ( I2 IA 2 ) R2 ( I2 IA 2 ) R3 IA
17 6.2 Voltage Drop of Extension Cable Since 5VDC is supplied to the QA6ADP from the power supply module mounted on the main base unit, the voltage drop will be caused in the extension cable. If the specified voltage (4.75VDC or more) is not supplied to the IN side connector of the QA6ADP+A5 B/A6 B,...
Page 19 - COMPATIBLE MODELS LIST; Power supply module, Extension cable
18 7. COMPATIBLE MODELS LIST This chapter describes external dimensions of the QA6ADP. 200 ( 7.87) 73.5 (2.89) 13 0 ( 5.11) 74 (2.91) I/O POWER I/O I/O I/O I/O QA6ADP QA conversion adapter module 2 6-M4 screw (for mounting module) Handle 4- 6mounting hole (M5 mounting screw) A series extension base ...