Page 2 - INTRODUCTION; EXTERNAL DIMENSIONS; TERMINAL LAYOUTS

● The FX 0N -232ADP type RS232C adapter (hereinafter called 232ADP) is connected to the FX 0N series PC to exchange serial data with a personal computer, barcode reader, printer, and other various RS232C devices. ● Only one 232ADP unit can be connected to one base unit to the serial port provided at...

Page 3 - Performance specification; INSTALLATION NOTES AND USAGE; General specification

Transmission standard Conforming to RS232C, 25pin D-SUB, connector used Isolation method Photo coupler isolation Transmission distance 15m or less (shielded cable recommended) Current consumption DC 5V less than 200mA from base unit Control flags and data registers M8121:Send wait flag D8120:System ...

Page 4 - Communication format D8120 (bit mapping)

*1 The default value is STX (02H: changeable). *2 The default value is ETX (03H: changeable). ● The communication format is set by special data register D8120. Setting the communication format using D8120 is effective only at the time the RS instruction is driven, and therefore any change after driv...