Page 2 - Electric Shock Prevention; This section is specifically about safety matters; SAFETY INSTRUCTIONS; WARNING
A-1 Thank you for choosing the Mitsubishi transistorized inverter option unit.This instruction manual gives handling information and precautions for use of this equipment. Incorrect handlingmight cause an unexpected fault. Before using the equipment, please read this manual carefully to use the equi...
Page 3 - Additional instructions
A-2 2. Injury Prevention 3. Additional instructions Also note the following points to prevent an accidental failure, injury, electric shock, etc.: (1) Transportation and mounting (2) Test operation and adjustment ! Any person who is involved in the wiring or inspection of this equipment should be fu...
Page 5 - CONTENTS
CONTENTS 1.PRE-OPERATION INSTRUCTIONS 1 1.1 Unpacking and Product Confirmation ..................................................................................................1 1.2 Packing Confirmation ...................................................................................................
Page 6 - Unpacking and Product Confirmation; SERIAL number; Packing Confirmation; Make sure that the package includes the following
1 1.PRE-OPERATION INSTRUCTIONS 1.1 Unpacking and Product Confirmation Take the option unit out of the package, check the unit name, and confirm that the product is as youordered and intact.Functions arailable differ between FR-A500(L)/F500(L) series and FR-V500 series, always check beforeusing. "...
Page 7 - PRE-OPERATION INSTRUCTIONS
2 PRE-OPERATION INSTRUCTIONS 1.3 Structure Front view Mounting holes Option fixing holes Terminal symbol Terminal block screw size M3 Rear view Connector FR-A5AR 1A 1B 2A 2B 3C 1C 3B Mounting holes 2C 3A Mounting hole ib66810b.book 2 ページ 2002年2月15日 金曜日 午前8時10分 Technologies Inc. Toll Free: voice: 1-8...
Page 8 - Make sure that the input power of the inverter is off.; Installation Procedure
3 2.INSTALLATION 2.1 Pre-Installation Instructions Make sure that the input power of the inverter is off. 2.2 Installation Procedure (1) Securely insert the connector of the option unit far into the connector of the inverter. At this time, fit the option fixing holes snugly. For the position of slot...
Page 9 - INSTALLATION; CAUTION; Mounting Position
4 INSTALLATION CAUTION 1. Only one type of option per inverter may be used. When two or more options are mounted, pri- ority is in order of slots 1, 2 and 3, the options having lower priority are inoperative. 2. When the inverter cannot recognize that the option is mounted, it displays the option er...
Page 10 - REMARKS
5 INSTALLATION 2.3 Wiring Route the wires so that they do not take up a lot of space in the control circuit terminal block of the option unit.During wiring, do not leave wire off-cuts in the inverter. They may cause a fault, failure or malfunction.Use the space on the left side of the control circui...
Page 11 - Internal Block Diagram; * The operation of each relay depends on the output signal selected.
6 3.FUNCTIONS 3.1 Internal Block Diagram 3.2 Terminals * The operation of each relay depends on the output signal selected. You can select any three output signals available with aninverter as standard, and output them as relay contant signals.Functions arailable differ between FR-A500(L)/F500(L) se...
Page 12 - REMAKS
7 4.PARAMETERS 4.1 Parameter List By installing this option unit, the parameters below are extended. Set the values according to need. The setting value of the parameter differs according to the inverter. Please refer to the inverter instructionmanual (output terminal function selection (Pr. 190 to)...