Page 3 - ii; OCATIONS
ii L OCATIONS C ORPORATE H EADQUARTERS N ORTH A MERICA E UROPEAN , M IDDLE E AST & A FRICAN H EADQUARTERS USA, N EW J ERSEY G ERMANY , M UNICH Metrologic Instruments, Inc. Metrologic Instruments GmbH Tel: 1-800-ID-METRO Fax: 856-228-6673 Tel: 49-89-89019-0 Fax: 49-89-89019-200 Email: info@metrol...
Page 4 - iii; ABLE OF
iii T ABLE OF C ONTENTS Introduction .......................................................................................................... 1 Scanner and Accessories .................................................................................... 1 Scanner Installation..........................
Page 7 - Default Settings
3 S CANNER C ONFIGURATION TO THE H OST S YSTEM The IS4220 is shipped from the factory pre-programmed to a set of default parameters. It may be necessary to change the default parameters to match the host system’s requirements or to enable additional scanner functions. For a list of possible paramete...
Page 8 - Scanner Parts; Item
4 P ARTS OF THE S CANNER Figure 1. Scanner Parts Item No. Description Green LED W hen a bar code is read successfully the green LED will flash. Red LED W hen the red LED is illuminated, the laser is on. Red Output Window (Laser Aperture) Infrared Sensor (IR) If a specified time has elapsed without a...
Page 9 - No Red LED; first; Steady Red; not
5 V ISUAL I NDICATORS There is a red and a green LED located on the top of the scanner. W hen the scanner is on, the flashing or constant illumination of the LEDs indicates the status of the current scan and the scanner. No Red LED Illumination of the LEDs will not occur if the scanner has remained ...
Page 14 - ABELS; Caution and Serial Number Labels*; AINTENANCE
10 L ABELS Each IS4220 has a serial number label and a laser class label on the bottom of the unit. These labels provide important information like; date and location of manufacture, model number, serial number, caution statements and laser class. There is also text molded into the top of the case n...
Page 15 - If the object is removed
11 I NFRARED (IR) O BJECT S ENSOR An infrared (IR) device located behind the window initiates the scanning process. The IR sensor is active as long as power is applied to the unit. W hen the IR sensor detects an object, the green LED will flash. W hen the laser decodes a bar code, the scanner transm...
Page 16 - Scan Field
12 Scan Field The depth of field for the scanner is 12.7 mm to 203 mm (.5" to 8") from the face of the output window for .33 (13 mil) Bar Codes. Figure 3. Scan Field for .33 (13 mil) Bar Codes Specifications subject to change without notice.
Page 17 - Specifications subject to change without notice.
13 S PECIFICATIONS IS4220 S PECIFICATIONS O PERATIONAL Light Source: 650 nm VLD Depth of Field: 12.7 mm to 203 mm (.5" to 8") for .33 (13 mil) bar code Width of Scan Field: 28.6 mm (1.125”) @ face; 102 mm (4”) @ 76.2 mm (3”) Scan Speed: 52 scans lines per second Scan Pattern: Single scan lin...
Page 18 - USB
14 D EFAULT S ETTINGS Many functions of the scanner can be "programmed", that is enabled or disabled. The scanner is shipped from the factory programmed to a set of default conditions. All factory default parameters have an asterisk ( * ) in the default column of the charts on the following ...
Page 23 - USB Keyboard Emulation
19 T ROUBLESHOOTING G UIDE The following guide is for reference purposes only. Contact a Metrologic representative at 1-800-ID-METRO or 1-800-436-3876 to preserve the limited warranty terms on page 20. S YMPTOMS P OSSIBLE C AUSE ( S ) S OLUTION No LEDs, beep and there is no visible laser No Power is...
Page 24 - scanners are manufactured by Metrologic at its Blackwood, New
20 L IMITED W ARRANTY The IS4220 ScanGlove ® scanners are manufactured by Metrologic at its Blackwood, New Jersey, U.S.A. facility. The IS4220 scanners have a two (2) year limited warranty from the date of manufacture. Metrologic warrants and represents that all IS4220 scanners are free of all defec...
Page 25 - OTICES
21 N OTICES Notice This equipment has been tested and found to comply with limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. Th...
Page 26 - European Standard; Warning; Standard Europeo; Attenzione
22 N OTICES European Standard Warning This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. Funkstöreigenschaften nach EN 55022:1998 Warnung! Dies ist eine Einrichtung der Klasse A. Diese Einri...
Page 28 - NDEX
24 I NDEX A application ..................................... 1 audible....................................... 5–9 autodiscriminates ........................ 13 B bar code .............. 4, 5–9, 10, 11, 19 beep ........................ 5–9, 13, 14, 19 C cable.................................... 1, 4...
Page 30 - OTES
Page 32 - Printed in the USA