Page 2 - IMPORTANT SAFETY INSTRUCTIONS; TOOLS AND MATERIALS REQUIRED
IMPORTANT SAFETY INSTRUCTIONS WARNING: TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: 1. Do not use this fan with any Solid-State Speed Control Device. 2. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manu...
Page 3 - ATTIC AIR INTAKE AND DISCHARGE; MINIMUM ATTIC DISCHARGE AREAS REQUIRED; FAN
(1/2 A X B = AREA Sq. Ft.) GABLE EXHAUST (A X B = AREA Sq. Ft.) EAVE EXHAUST (A X B = AREA Sq. Ft.) GABLE EXHAUST ATTIC AIR INTAKE AND DISCHARGE Your Whole House Ventilator will be discharging a large volume of air into the attic every minute.Provisions must be made to allow this air to escape to th...
Page 4 - CEILING INSTALLATION —; USED WITH AN A3024 SHUTTER ONLY; ” opening on ceiling below where shutter is to be located, or 30
3 CEILING INSTALLATION — MODEL 3038 USED WITH AN A3024 SHUTTER ONLY NO FRAMING OR CUTTING OF JOISTS REQUIRED FOR 16” O.C. JOISTS. FAN LOCATION AND MOUNTING STEP 1 - Fan should be located in center of house, preferably in hallway or corridor. This will allow air tobe drawn from all parts of living sp...
Page 7 - SHUTTER INSTALLATION
SHUTTER INSTALLATION STEP 7 - Unpack Model A3024 shutter and read instructions included. Note that the first part of the shutterinstructions refer to cutting the shutter hole, which you have already done, and so they may be disregard-ed. Follow the remaining instructions to adjust springs so that sh...
Page 8 - CEILING INSTALLATION — ALL OTHER MODELS; FAN LOCATION & MOUNTING
7 CEILING INSTALLATION — ALL OTHER MODELS FAN LOCATION & MOUNTING STEP 1 - Fan should be located in center of house, preferably in hallway or corridor. This will allow air tobe drawn from all parts of living space. (See Fig. 1.) STEP 2 - Lightly mark a square opening on ceiling (with pencil) whe...
Page 10 - FAN MODEL; Frame inside opening per chart below.; STEP 4 - Now carefully cut hole in ceiling flush with inside of frame.
9 FOR CEILINGS WITH 2 X 4 JOISTS ON 24” CENTERS Determine which ceiling joists are to be cut per STEPS 2 & 3. Locate your fan size below and follow specific instructions. FOR CEILINGS WITH 2 X 6 JOISTS ON 24” CENTERS Determine which ceiling joists are to be cut per STEPS 2 & 3. Locate your f...
Page 11 - 20V SUPPLY AVAILABLE AT FAN
10 BROWN WHITE BLACK WHITE (COM) RED (LOW) RED (LOW) BLUE (MED) BLACK (HI) BLUE (MED) BLACK (HI) SHUTTER INSTALLATION STEP 6 - Unpack shutter and read instructions included. Carefully follow these instructions to adjust thespring tension on your shutter. Make sure the shutter opens and closes freely...
Page 12 - 20V SUPPLY AVAILABLE AT CONTROL; this procedure and installation.
11 120V, 60 HZ FIG. 15 FAN MOTOR OUTLET BOX CONTROL OUTLET BOX GND. SCREW BLACK (HI) BLUE (MED) MOTOR RED (LOW) BLACK (HI) BLUE (MED) RED (LOW) WHITE (COM) CONTROL BLACK BROWN 120V SUPPLY AVAILABLE AT CONTROL WHITE STEP 4 - After determining which diagram applies, pull wires to fan. Be sure to secur...
Page 13 - FAN SIZE
12 STEP 5—Position fan on frame and secure with (4) wood or lag screws (number 12 x 1 1/2” preferred) through holes drilled inSTEP 4. FIG. 4 FIG. 5 SEE CHART DOUBLE 2 X 6HEADER 2 X 4 FRAMING SECURE UNIT IN PLACE WITH 2” X 2” FURRING STRIPS INSIDE. SECURE UNIT IN PLACE OUTSIDE WITH MOULDING STEP 6—Un...
Page 16 - LIMITED WARRANTY; HOW TO ORDER REPAIR PARTS
LIMITED WARRANTY Dear Customer, Thank you for your interest in Marley Engineered Products products. We’re sure you willenjoy its benefits for many years to come. Please take a minute to fill out the followinginformation and keep it in your permanent records. Date Purchased Date Installed Model Numbe...