Marley E4209-1325HFD - Manual
Marley E4209-1325HFD – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – General Safety Information
- Page 3 – Installation; FIELD POWER WIRING; Figure 5 - Wiring Diagram
- Page 4 – LUBRICATION
- Page 5 – Troubleshooting Chart; SYMPTOM; Fan inoperative
- Page 7 – Key
- Page 8 – HOW TO ORDER REPAIR PARTS; In order to obtain any needed repair or replacement; LIMITED WARRANTY
Specifications and Performance
INSTALLATION & OPERATING INSTRUCTIONS & PARTS MANUAL
MODELS:
E3606-1325HFD, E3609-1325HFD
E3806-1325HFD, E3809-1325HFD
E4206-1325HFD, E4209-1325HFD
E4806-1325HFD, E4809-1325HFD
E6006-2325HFD, E6009-2325HFD
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE, OR MAINTAIN THE PRODUCT DESCRIBED.
PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS
COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
Air curtains produce a wall of continuously flowing air
that acts as a thermal barrier against outside air and
provides protection against insects, dust, odor, fumes
and other contaminant’s. Maintains interior conditioned
temperature by preventing heated or cooled air from
escaping through open doorways.
Heated air curtains are engineered to treat incoming
cold air at customers’ entrance areas. Used over front
door entrances, heated air curtains supplement existing
heat to prevent infiltration of colder outside air. Heated
units are not recommended for areas subject to high
winds.
Figure 2 Dimensions
Note that all dimensions are the same on all environmental
series units. Model number indicates width of unit.
(Example: E4800 indicates a 48” wide unit.)
MODEL
NUMBER
E3606-1325HFD
E3609-1325HFD
E4206-1325HFD
E4209-1325HFD
E4806-1325HFD
E4809-1325HFD
E6006-2325HFD
E6009-2325HFD
HEATER
VOLTAGE
208/3
208/3
208/3
208/3
208/3
208/3
208/3
208/3
MOTOR
VOLTAGE
208/3
208/3
208/3
208/3
208/3
208/3
208/3
208/3
HEATER
WATTS
6000
9000
6000
9000
6000
9000
6000
9000
HEATER
BTU/HR
HEATER
AMPS
20,478
30,717
20,478
30,717
20,478
30,717
20,478
30,717
16.7
25.0
16.7
25.0
16.7
25.0
16.7
25.0
CFM AT NOZZLE
(HI/LOW)
2025
2025
2360
2360
2700
2700
3375
3375
MOTOR
SIZE
1/4HP
1/4HP
1/4HP
1/4HP
1/4HP
1/4HP
1/4HP
1/4HP
Heated
Air Curtains
Note: For multiple unit installations, recommended spacing between units should be a minimum of 3-inches and a maximum of 6-inches.
Unit is allowed to extend beyond doorway width. Each unit must have individual power supply.
Description
REFER TO INDIVIDUAL MODEL NUMBERS
FOR UNIT WIDTH
11
7
/
8
”
15
3
/
4
”
12
1
/
2
”
Figure 1
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
5. Carefully disconnect motor electric cord and heater plug assembly and remove two wing nuts on blowerbase. (See Figure 4.) Figure 4 - Removing Motor/Blower Assembly NOTE: Unit is shipped with styrofoam motor supportblock which must be discarded at this time.6. To remove motor/blower assembly, lift...
Installation 1. Using template provided, determine mounting loca- tion. 2. Drill holes and attach mounting hardware (not includ- ed). IMPORTANT: THE HARDWARE AND THE SUPPORT-ING STRUCTURE MUST BE CAPABLE OF SUPPORT-ING A MINIMUM 150 LB. LOAD. NOTE: All installation should be done to meet localbuildi...
Operation 1. After power has been connected to unit, fans will start in either preset (high/low) speed selection. 2. Air velocity is controlled by selection of high or low speed indicator. This feature allows the setting of airvelocity to individual desired performance and energyefficiency. 3. Air d...