DAY OF WEEK TIME PROGRAM PERIOD TEMPERATURE MODE SWITCH LIGHTBUTTON FAN SWITCH 1. FEATURES • Extra Large Hybrid Touch Screen Display• Audible Touch Confirmation• EL Display Illumination• Elegant Design• 7 Day Programming• Energy Star ® Compliant • 4 Periods Per Day• Battery Free Memory For All Progr...
Page 4 - OPERATING INSTRUCTIONS; For; MENU; : Touch this key to begin viewing available; SCROLL; : Use this key to see the available menu; YES; Touch this key to return to the main; REPLACE
18. Verify that the system and its fan areoperating properly. When set to a hightemperature, the heating system should providewarm air after a short time. Likewise a coolingsystem should provide cool air after a short time.Usually sound from the furnace and airconditioning units can be heard while t...
Page 6 - FILTER LIFE IN DAYS SET COUNTER HOURS TO
• Set the mode switch to HEAT to program theunit for controlling your heater. Set the modeswitch to COOL to program the unit for controllingyour air conditioner.• Touch MENU . • Use SCROLL to advance to SET/REVIEW HEAT PROGRAMS or SET/REVIEW COOL PROGRAMS.• Touch YES to begin scrolling through the H...
Page 7 - See
• Use UP/DOWN arrows to adjust. • Touch EXIT to return to main display. 6.3. TEMPERATURE CALIBRATION • From the main menu touch MENU . • SCROLL to CAL TEMP.• Touch YES . CAL TEMP will be visible and adjustment value will be flashing.• Use UP/DOWN arrows to adjust offset value. • Touch EXIT to return...
Page 8 - This table is printed on the circuit board.; To; BATTERIES AND MAINTENANCE; indicator appears in; at least once a year; To access your units batteries remove the unit; Install two new Energizer; TECHNICAL ASSISTANCE; before returning; ON
• Maximum Smart Recovery time is one hour.• The Smart Recovery temperature set point mustbe achievable. If a desired smart recovery isrepeatedly ignored by your thermostat. That is anindicator that you should modify your program sothat the recovery can be achieved within the 1hour limit.• A Smart Re...
Page 9 - + 6 Wire 2 Transformers; HEATING/COOLING SYSTEMS; + 5 Wire 1 Transformers; COOLING SYSTEMS; WIRING DIAGRAM NOTES (APPLIES TO ALL DRAWINGS)
9 HEATING/COOLING SYSTEMS 5 + 6 Wire 2 Transformers COMMON FOR SYSTEM POWER 2 + 3 WIRE HEATING SYSTEMS COMMON FOR SYSTEM POWER HEATING/COOLING SYSTEMS 4 + 5 Wire 1 Transformers COMMON FOR SYSTEM POWER COOLING SYSTEMS COMMON FOR SYSTEM POWER C RH RC O B G Y W W H 4 Y C* 6 G F RC R RH V 5 JUMPER REMOV...
Page 10 - WIRE, 24 VOLT AND MILLIVOLT HEAT ONLY SYSTEMS; WIRE COOLING SYSTEM; PROVIDED
10 W Y G B O RC RH C 2 WIRE, 24 VOLT AND MILLIVOLT HEAT ONLY SYSTEMS 24 VOLT HEAT TRANSFORMER 120 VAC HEAT SYSTEM COMMON OPTIONAL RC-RH JUMPER PROVIDED W Y G B O RC RH C 3 WIRE HEATING SYSTEM (3RD WIRE FOR FAN) 24 VOLT HEAT TRANSFORMER 120 VAC FAN HEAT SYSTEM COMMON OPTIONAL RC-RH JUMPER PROVIDED W ...
Page 11 - WIRE HEATING AND COOLING SYSTEM; WIRE SYSTEM HEATING AND COOLING - 2 TRANSFORMERS; REMOVED; SINGLE STAGE HEAT PUMP SYSTEM; ADD
11 W Y G B O RC RH C 4 WIRE HEATING AND COOLING SYSTEM 24 VOLT SYSTEM TRANSFORMER 120 VAC AC COMPRESSOR FAN HEAT OPTIONAL SYSTEM COMMON RC-RH JUMPER PROVIDED W Y G B O RC RH C 5 WIRE SYSTEM HEATING AND COOLING - 2 TRANSFORMERS 24 VOLT HEAT TRANSFORMER 120 VAC 24 VOLT COOL TRANSFORMER 120 VAC FAN COO...
Page 12 - JUMPER AND SWITCH POSITIONS
12 WARNING: Use Energizer ® or DURACELL ® Alkaline Batteries Only. Energizer ® is a registered trademark of Eveready Battery Company, Inc. DURACELL ® is a registered trademark of The Gillette Company, Inc. DAY MON MORN DAY EVE NIGHT MORN DAY EVE NIGHT MORN DAY EVE NIGHT TUES WED PERIOD HEAT TIME TEM...