Page 2 - LUXPRO
Page 3 - Thermostat and; INSTRUCTION MANUAL
O OU UT TD DO OO OR R W WIIR RE ELLE ES SS S T TE EM MP PE ER RA AT TU UR RE E T TR RA AN NS SM MIIT TT TE ER R A AN ND D R RE EC CE EIIV VE ER R K KIIT T LUXPRO ® Part No. WTR064 Outdoor Wireless Temperature Transmitter and Receiver Kit Includes: TransmitterAntennaReceiver Module2 AA Batteries U.S....
Page 5 - TABLE OF CONTENTS
TABLE OF CONTENTS...................................................................................................................5GLOSSARY OF TERMS ..................................................................................................................6SELECTING A LOCATION ................
Page 6 - GLOSSARY OF TERMS
GLOSSARY OF TERMS 6 LUXPRO ® PSPU732T CYCLE RATE - Cycle rate is the frequency that heating or cooling equipment is turned on during a certain period of time. Cycle rate is often given in units of cycles per hour (CPH). DEHUMIDIFY - The process of removing moisture from the air. DEHUMIDIFIER - Devic...
Page 7 - SELECTING A LOCATION
Install your LUXPRO ® thermostat approximately 5 feet (1.5 meters) above the floor in an area with good air circulation. Avoid the following locations: • Hot or cold air from ducts • Radiant heat for appliances or sun such as a skylight • Unheated or uncooled areas: for example an outside wall behin...
Page 8 - MOUNTING THE THERMOSTAT TO THE WALL
MOUNTING THE THERMOSTAT TO THE WALL 8 LUXPRO ® PSPU732T 1. Make sure to turn off the power supply located at the electrical service panel.All heating and cooling units should be OFF. 2. Separate the backplate from the thermostat by grasping the unit firmly at the bottom lip andpulling gently until t...
Page 9 - WIRING LEGEND
TERMINAL EQUIPMENT STANDARD COLOR Y1 First Heat Pump and AC Yellow G Fan Green W2 First Stage Furnace White OBW Reverse Valve - Second Stage Furnace Orange RH 24v Red Y2 Second Heat Pump and AC Unknown C Common Blue H Humidity Control Unknown DH Dehumidify Control, Variable Fan Control Unknown RC 24...
Page 10 - WIRING DIAGRAMS; AIR CONDITIONER; I1 RC DH H C
WIRING DIAGRAMS 10 LUXPRO ® PSPU732T I2 1 AIR CONDITIONER 24V FANAC I1 RC DH H C Y2 RH OBW W2 G Y1 COMMON COOL 2 I2 2 STAGE COOL 24V FANCOOL 1 I1 RC DH H C Y2 RH OBW W2 G Y1 COMMON
Page 11 - AIR CONDITIONER AND 2 STAGE HEAT; AIR CONDITIONER AND 1 STAGE HEAT
HEAT 2HEAT 1 I2 1 AIR CONDITIONER AND 2 STAGE HEAT 24V FANAC I1 RC DH H C Y2 RH OBW W2 G Y1 COMMON HEAT I2 1 AIR CONDITIONER AND 1 STAGE HEAT 24V FANAC I1 RC DH H C Y2 RH OBW W2 G Y1 COMMON WIRING DIAGRAMS 11 INSTRUCTION MANUAL
Page 12 - HEAT PUMP AND 1 STAGE HEAT; HEAT PUMP
HEAT REVERSE VALVES I2 1 HEAT PUMP AND 1 STAGE HEAT 24V FANHP I1 RC DH H C Y2 RH OBW W2 G Y1 COMMON REVERSE VALVES I2 1 HEAT PUMP 24V FANHP I1 RC DH H C Y2 RH OBW W2 G Y1 COMMON WIRING DIAGRAMS 12 LUXPRO ® PSPU732T
Page 13 - HEAT PUMPS; HEAT PUMP AND 2 STAGE HEAT
WIRING DIAGRAMS 13 INSTRUCTION MANUAL I2 COMMON 2 HEAT PUMPS HP224VREVERSE VALVES FANHP1 I1 RC DH H C Y2 RH OBW W2 G Y1 I2 COMMON 1 HEAT PUMP AND 2 STAGE HEAT HEAT 224VREVERSE VALVESHEAT 1FANHP I1 RC DH H C Y2 RH OBW W2 G Y1
Page 14 - TRANSFORMERS; CUT; RH OBW W2 G Y1; TRANSFORMER
HEAT TRANSFORMER COOL TRANSFORMER I2 2 TRANSFORMERS I1 RC DH H C Y2 CUT RH OBW W2 G Y1 I2 1 TRANSFORMER I1 RC DH H C Y2 RH OBW W2 G Y1 HEAT TRANSFORMER WIRING DIAGRAMS 14 LUXPRO ® PSPU732T
Page 15 - HUMIDIFIER WITHOUT TRANSFORMER
WIRING DIAGRAMS 15 INSTRUCTION MANUAL I2 HUMIDIFIER WITHOUT TRANSFORMER 24V I1 RC DH H C Y2 RH OBW W2 G Y1 HUMIDIFIER 2nd WIRE HUMIDIFIER 1st WIRE
Page 16 - HOME SCREEN
Current RoomTemperature Current Room Humidity Current OutdoorTemperature Current Thermostat OperationMode Current Temperature Control Mode Current Fan Operation Mode Fan Operation Indicator Vacation Mode Indicator Security Indicator Heat setpoint Cool setpoint Date Time HOME SCREEN 16 LUXPRO ® PSPU7...
Page 17 - CONTROL SCREEN
Change the Temperature Setpoint(s) using - and + buttons. In AUTO MODE toggle the Heat/Cool button (Heat or Cool will flashonce selected), then raise or lower setpoints as desired. Change the Humidity Setpoint using - and + buttons. Select the Thermostat Operation Mode by toggling thermostat operati...
Page 18 - THERMOSTAT OPERATION MODES
THERMOSTAT OPERATION MODES 18 LUXPRO ® PSPU732T >> LUXPRO ® thermostat can operate in PROGRAM MODE or can HOLD a fixed temperature. RUN PROGRAM : the thermostat initiates the 7-day Programmable Temperature Control Program with 4 independent events per day. To set up a custom tem-perature contr...
Page 19 - TEMPERATURE CONTROL MODES
>> Based on your HVAC equipment LUXPRO ® thermostat can operate in the following tempera- ture control modes - AUTO or HEAT or EMERGENCY HEAT or COOL or OFF AUTO - the thermostat keeps the room temperature between the selected HEAT and COOL setpoints by using both the cooling and heating HVAC ...
Page 20 - AUTOMATIC HUMIDITY CONTROL
AUTOMATIC HUMIDITY CONTROL 20 LUXPRO ® PSPU732T >> In order to reduce condensation, humidity must be controlled and air movement must begenerated. As the exterior temperature drops, the humidity level needs to decrease ifcondensation is to be controlled. HUMIDITY AUTO : the thermostat automati...
Page 21 - HUMIDIFY AND HUMIDITY SETPOINT
>> HUMIDIFY SETPOINT : Allows you to increase and maintain the relative humidity at a specif- ic setpoint. Once you choose HUMIDIFY follow these easy steps: • The HUM setpoint with - and + icons allow you to lower and raise your setpoint. * Example of the typical use of the Humidify Function: ...
Page 22 - DE-HUMIDIFY AND HUMIDITY SETPOINT
DE-HUMIDIFY AND HUMIDITY SETPOINT 22 LUXPRO ® PSPU732T >> DE-HUMIDIFY SETPOINT : Allows you to reduce and maintain the relative humidity at a specific setpoint. >> Please note that this feature functions in the COOL Mode only. Your LUXPRO ® hermostat must be configured to control a cooli...
Page 23 - FAN OPERATION MODES
FAN OPERATION MODES 23 INSTRUCTION MANUAL >> LUXPRO ® thermostat can operate the fan in one of the following three modes: FAN AUTO : The fan runs only when there is a demand for heating or cool- ing. FAN ON : The fan runs continuously FAN INTERMITTENT : The fan runs 10 minutes per 1/2 hour pro...
Page 24 - MENU SCREEN
MENU SCREEN 24 LUXPRO ® PSPU732T >> To access the MENU SCREEN, simply touch MENU from the CONTROL SCREEN. >> From the MENU page, you can: Access DATE AND TIME SETTINGS to enter the accurate date and time Access PROGRAM SETTINGS to pre-program temperature changes during each day of the we...
Page 26 - DATE AND TIME SETTINGS
26 LUXPRO ® PSPU732T DATE AND TIME SETTINGS Select the 12 OR 24 HOUR CLOCK display by pushing the corresponding button. Set the TIME by togggling hour, minute and AM/PM buttons. Set the DATE by toggling Month, Day and Year buttons.
Page 27 - PROGRAM SETTINGS
PROGRAM SETTINGS PROGRAM SETTINGS feature allows you to easily and quickly program daily temperature changes to fit your lifestyle and reduce energy con-sumption. You can customize the program for each day of the week with4 independent temperature and fan operation settings per day. To setupyour pro...
Page 29 - SET SCREEN OPTIONS
SET SCREEN OPTIONS • BACKLIGHT: Select between automatic and permanent backlight for the screen. AUTO: The screen back-light will come on only when you touch the screen. ON: Screen will constantly be back-lit. • REVERSE : Select the positive or negative screen display. ON: Negative Display (Dark Bac...
Page 30 - VACATION MODE
30 LUXPRO ® PSPU732T VACATION MODE >> VACATION SETTINGS allows you to set the temperature to a fixed setpoint during the time you are on vacation, providing energy savings without compromising comfort upon your return. IMPORTANT: HEAT or COOL must be selected from the CONTROL SCREEN before ent...
Page 31 - FILTER MONITOR
FILTER MONITOR FILTER MONITOR: Displays filter usage in days RESET: Resets filter timer (You should reset FILTER MONITOR after chang- ing the air filter. When activated the FILTER MONITOR icon appears on your HOME SCREEN- this feature must be activated in ADVANCED SETTINGS. 31 INSTRUCTION MANUAL
Page 32 - ADVANCED SETTINGS - FEATURES SETTINGS
• DAYLIGHT TIME : Choose Daylight Time ON or OFF dependent on your Time Zone. FILTER: Enter the air filter "fan run time" infor- mation here. The Filter Monitor feature uses thisinformation to inform you when to change yourair filter by displaying CHANGE FILTER icon on theHOME SCREEN. ENERGY...
Page 34 - ADVANCED SETTINGS - SYSTEM CONFIGURATION
ADVANCED SETTINGS - SYSTEM CONFIGURATION 34 LUXPRO ® PSPU732T ! IMPORTANT: By inadvertently modifying system configuration settings, you may seri- ously degrade HVAC system performance. >> Choose system heating and cooling equipment - remember all you need to do is toggle the appropriate butto...
Page 35 - ADVANCED SETTINGS - DUAL FUEL SWITCH
! IMPORTANT: This feature can only be activated when used with the LUXPRO ® Outdoor Wireless Temperature Transmitter and Receiver. Please install the LUXPRO ® Outdoor Wireless Temperature Transmitter and Receiver before activating this feature. Increasing energy efficiency and reducing costs can be ...
Page 36 - ADVANCED SETTINGS - DIFFERENTIAL SETTINGS
ADVANCED SETTINGS - DIFFERENTIAL SETTINGS 36 LUXPRO ® PSPU732T >> LUXPRO ® PSPU732T allows you to control up to 3 Stages of Heating and 2 Stages of Cooling, dependent on the type of system you have configured. • 1ST STAGE DIFFERENTIAL : Set temperature difference between temperature set point ...
Page 37 - ADVANCED SETTINGS - TIMER FEATURE
• Specify the number of minutes for which Stage 1 will function until Stage 2 is activated to helpraise (or cool) temperature (if the temperature set point is not reached). This unique functionavoids excess compressor wear in the case where the necessary temperature set point is not metthrough setti...
Page 38 - ADVANCED SETTINGS - HEAT PUMP
ADVANCED SETTINGS - HEAT PUMP 38 LUXPRO ® PSPU732T • HP ON when Furnace On: Heat Pump and Furnace can operate together when 2nd stage fur- nace is required. HP “OFF” when Furnace On: turns off the Heat Pump when the furnace is On(required on some gas or oil furnaces).
Page 39 - ADVANCED SETTINGS - HUMIDITY SETTINGS
>> IMPORTANT: The Automatic Humidity Control feature can only be activated when used with the LUXPRO ® Outdoor Wireless Temperature Transmitter and Receiver. Please install the LUXPRO ® Outdoor Wireless Temperature Transmitter and Receiver before activating this feature. Automatic Humidity Con...
Page 42 - ADVANCED SETTINGS - CALIBRATION
ADVANCED SETTINGS - CALIBRATION 42 LUXPRO ® PSPU732T >> Calibration of Temperature or Relative Humidity Your LUXPRO ® thermostat is rated for ±1°F (±0.5°C) temperature accuracy and ± 4% for relative humidity accuracy. If you have determined due to drafts, sunlight or other environmental factor...
Page 43 - Calibration Number
>> Temperature Calibration Table • Determine the temperature difference using an accurate thermometer and use the following tableto calibrate your thermostat. The thermostat temperature reading can be calibrated by ±19°F (±9.5°C). ADVANCED SETTINGS - CALIBRATION 43 INSTRUCTION MANUAL Calibrati...
Page 44 - SIMPLE THERMOSTAT MODE
SIMPLE THERMOSTAT MODE 44 LUXPRO ® PSPU732T >> LUXPRO ® thermostat can also function as a virtual non-programmable thermostat after it has been switched to a “SIMPLE MODE”. >> To enable “SIMPLE MODE”, press the reset button (take off the thermostat faceplate and press the reset button lo...
Page 45 - TROUBLESHOOTING
? Touch screen buttons do not function properly . Remove cover, press the reset button located in the bottom left corner then accurately touch 3 target centers on the screen when prompted. ? Air Conditioning does not turn on even when room temperature is higher then the temper- ature set point set p...
Page 46 - IMPORTANT NOTICE
IMPORTANT NOTICE 46 LUXPRO ® PSPU732T >> WHEN USING THIS THERMOSTAT WITH A GAS FURNACE A COMMON WIRE (C) MUST BE CONNECTED. When working without a common wire: >> A confirm in HEAT MODE the cooling does not switch on or B confirm in COOL MODE the heat do- es not switch on. >> If te...
Page 47 - WARRANTY
HARDWARE LUX Products Corporation warrants the original end user (“Customer”) that new LUXPRO ® branded products will be free from defects in workmanship and materials, under normal use, for three (3) years from theoriginal purchase date. SOFTWARE LUX Products Corporation warrants to Customer that t...