Page 3 - INTRODUCTION; TABLE OF CONTENTS; GENERAL INFORMATION; Installation and repair should be; Burner Orifi ce Sizes; Table 3
3 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. CONGRATULATIONS! In selecting this Lennox B-Vent Gas Appliance you have chosen the fi nest and most dependable fi replace to be found anywhere. A beautiful, prestigious, alternative to a wood burning fi replace. Welcome to a Family of tens of th...
Page 4 - Electronic Appliances -; . If your electronic appliance is; Honeywell Electronic Gas Valve; Figure 2; Figure 1; Millivolt Appliances -; English; Millivolt appliance; Figure 3 on Page; WARNING
4 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Variable Flame Height Adjustment ( Millivolt Appliances only) 1. All Millivolt appliances are equipped with a variable gas control valve. Flame height for these models may be adjusted through a range between fi xed low and high settings, alterna...
Page 5 - SIT Millivolt Gas Valve; Outside Combustion Air Controls; Combustion Air Control Lever; Figure 4
5 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 3. Keep lower control compartment clean by vacuuming or brushing at least twice a year. More frequent cleaning may be required due to excessive lint from carpeting, bedding materials, etc. It is important that control compartments, burners and c...
Page 6 - Spillage Test
6 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 6 - If the smoke is not drawn towards the edges of the glass door turn off the appliance and call a qualifi ed service technican. Manual-Reset Safety Limit Switch This appliance is equipped with a manual reset blocked fl ue safety limit switch. ...
Page 7 - Annually
7 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. MAINTENANCE TASK ACCOMPLISHING PERSON PROCEDURE Inspecting/Cleaning Burner, Logs and Controls Qualifi ed Service Technician Inspect valve and ensure it is properly operating. Check piping for leaks. Vacuum the control compartment, fi replace log...
Page 8 - Maintenance; Figure 5; Detail A; Limit; IMPORTANT
8 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. To install the front glass enclosure panel, proceed as follows: 1. Retrieve the glass door frame. Visually inspect the gasket on the backside of the panel. The gasket surface must be clean, free of irregularities and seated fi rmly. 2. Position ...
Page 9 - Burner Adjustments; The; Burner Air Shutter Adjustment; Figure 8
9 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Electronic Appliance Checkout To light the burner, refer to the lighting instruc-tions on Page s 20 and 21 . Ensure the igniter lights the pilot. The pilot fl ame should engulf the fl ame sensor as shown in Figure 9. With proper care and mainten...
Page 10 - Initial Installation Considerations; Remove the appliance front door.; Log Placement
10 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Figure 10 Figure 11 Figure 12 Burner Flame Appearance - Model MPB-3328 Burner Flame Appearance - Model MPB-3530 Burner Flame Appearance - Model MPB-4035 & MPB-4540 Initial Installation Considerations The packaged logs are located within the...
Page 11 - REFERENCE; Table 4; Glowing Embers; Bag of Glowing
11 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Glowing Embers, Vermiculite, Decorative Volcanic Stone And Log Placement Instructions: Step 1. Separate the Glowing Embers (Rockwool) into pieces about the size of a quarter (see Figure 13) . Keep the pieces fl uffed up, not matted. MPB-3328 &a...
Page 15 - WIRING DIAGRAMS; WARRANTY; The model number of the appliance.
15 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. WIRING DIAGRAMS Wiring diagrams are provided here for reference purposes only. This information is also provided on schematics attached directly to the appliance on a pullout panel located within the control compartment. CAUTION: LABEL ALL WIRE...
Page 16 - ACCESSORY COMPONENTS; Standard Remote Control System; Outside Combustion Air Kits; Polished Brass & Brushed Stainless Louvers Kits
16 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Remote Control Kit, Standard Cat. No. Model No. Description H0249 RCL Remote Control System (Standard) Rocker Switch Kit Cat. No. Model No. Description 80L41 FRS Rocker Switch Kit Forced Air Blower Kits Cat. No. Model No. Description 80L84 FBK-...
Page 17 - Arch Door Kits; Polished Brass & Brushed Stainless Hood Kits; Eyebrow Hood Kits; Polished Brass & Brushed Stainless 2-Piece Door Frame Kits; - Piece Door Frame Kits; Door Frame Kits; Piece Door Trim Kits; Brickaded Panel Liner Kit; -PIECE LOUVER SET KITS; -Piece Polished Brass and Brushed Stainless Louvers Kits
17 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Arch Door Kit - Polished Brass Cat. No. Model Models-Where Used 98L05 ADK33CPB MPB-3328 26M43 ADK35CMPB MPB-3530 81L35 ADK40CPB MPB-4035 81L36 ADK45CPB MPB-4540 Arch Door Kit - Brushed Stainless Steel Cat. No. Model Models-Where Used 98L62 ADK3...
Page 18 - and 4-Piece Trim Kits; Screen Panel Kit
18 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. ARCH DESIGN SCREEN DOOR KITS Cat. No. Model Description Where Used H0858 AD35C 35” Arch Doors, Charcoal MPB3530 H0859 AD35TI 35” Arch Doors, Textured Iron H0860 AD35SP 35” Arch Doors, Satin Pewter H0861 AD35AB 35” Arch Doors, Antique Brass H086...
Page 19 - Decorative Arch Screen Panel Kit; Sunrise Style; Decorative Grille Kits; Tall Style View Doors
19 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Decorative Arch Screen Panel Kit Cat. No. Model Model H3592 DASPK33TI 33” Dec. Arch Screen Panel H3593 DASPK35TI 35” Dec. Arch Screen Panel H3594 DASPK40TI 40” Dec. Arch Screen Panel Decorative Arch Screen Panel Kit This easy to install optiona...
Page 20 - LIGHTING INSTRUCTIONS – SIT MILLIVOLT GAS VALVE; FOR YOUR SAFETY READ BEFORE LIGHTING; Knob cannot be turned from “PILOT” to “OFF”; SIT
20 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. LIGHTING INSTRUCTIONS – SIT MILLIVOLT GAS VALVE WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. FOR YOUR SAFETY READ BEFORE LIGHTING A. This appl...
Page 21 - INSTRUCTIONS D’ALLUMAGE – VANNE GAZ MILLIVOLT SIT; INSTRUCTIONS D'ALLUMAGE; Il est impossible de tourner le bouton de “PILOT” à “OFF” à; POUR FERMER LE GAZ QUI ALIMENTE L’APPAREIL; VANNE GAZ
21 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. INSTRUCTIONS D’ALLUMAGE – VANNE GAZ MILLIVOLT SIT INSTRUCTIONS D'ALLUMAGE 8. Enfoncez le bouton de réglage jusqu’au fond et gardez-le enfoncé.Allumez immédiatement la veilleuse en déclenchant l’a...
Page 22 - LIGHTING INSTRUCTIONS — ELECTRONIC; TO TURN OFF GAS TO APPLIANCE; Honeywell Electronic Gas Control Valve
22 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. A. When lighting the appliance, follow these instructions exactly. B. BEFORE OPERATING smell all ...
Page 23 - INSTRUCTIONS D’ALLUMAGE — ELECTRONIC; INSTRUCTIONS D’ALLUMAGE; POUR ÉTEINDRE L’APPAREIL; Interrupteur; Vue de face
23 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. INSTRUCTIONS D’ALLUMAGE — ELECTRONIC INSTRUCTIONS D’ALLUMAGE POUR VOTRE SÉCURITÉ, LISEZ CES INSTRUCTIONS AVANT L’ALLUMAGE A. Lorsque vous allumez l’appareil, suivez exactement ces instruc-tions. B. AVANT L’ALLUMAGE: Assurez-vous que vous ne détecte...
Page 24 - TROUBLESHOOTING GUIDE - MILLIVOLT GAS CONTROL SYSTEM; TROUBLESHOOTING; Before replacing “OFF/ON” switch, Ensure to; TROUBLESHOOTING GUIDE - ELECTRONIC IGNITION SYSTEM
24 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. TROUBLESHOOTING GUIDE - MILLIVOLT GAS CONTROL SYSTEM Note: Before troubleshooting the gas control system, Ensure external gas shut off valve, located at gas supply inlet, (and wall switch, iff applicable), is in the “ON” position. Important: Va...
Page 25 - TROUBLESHOOTING PROCEDURE - ELECTRONIC IGNITION SYSTEM
25 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. START CHECK • Turn Off Gas Supply. • Ensure Valve Switch Is In ON Position. • Disconnect Control Harness. • Turn On Optional Remote Switch (if applicable) • Check for proper volt- age at control harness (see insert A). Voltage should be 24V bet...
Page 27 - REPLACEMENT PARTS
27 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. REPLACEMENT PARTS 4 7 1 2 5 40 13 12 42 3 8 9 40/45 14 15 9 33/35 20 21 10 40/45 33/35 10 23 22 26 24 25 27 41 43 44 14 Located Inside (see Figure 8 ) 11 15 6 Located Inside (see Figure 5 on Page 8)