Page 3 - Customer Service; Finding information and software
Customer Service CellPipe™ 20 Series User’s Guide iii Customer Service Product and service information, and software upgrades, are available 24 hours a day. Technical assistance options accommodate varying levels of urgency. Finding information and software To obtain software upgrades, release notes...
Page 4 - Obtaining assistance through email or the Internet
Customer Service iv CellPipe™ 20 Series User’s Guide Obtaining assistance through email or the Internet If your services agreement allows, you can communicate directly with a technical engineer through Email Technical Support or a Live Chat. Select one of these sites when you log in to http://www.lu...
Page 5 - Contents
CellPipe™ 20 Series User’s Guide v Contents Customer Service ..................................................................................................... iii Introduction .......................................................................... 1-1 About this guide ...........................
Page 7 - Introduction; About this guide
CellPipe™ 20 Series User’s Guide 1-1 1 Introduction About this guide This document is a combined user’s guide for the CellPipe™ 20 Series Product Family. The products currently addressed by this guide include the following: • CellPipe 20A-GX, supporting software version 1.65LU • CellPipe 20S, suppor...
Page 8 - What is the CellPipe 20 Series Product Family?
IntroductionWhat is the CellPipe 20 Series Product Family? 1-2 CellPipe™ 20 Series User’s Guide What is the CellPipe 20 Series Product Family? The current CellPipe 20 Series Product Family consists of two groups of products—symmetrical digital subscriber line (SDSL) and asymmetrical digital subscrib...
Page 9 - CellPipe 20 Series management
Introduction Lucent TURN-UP CellPipe™ 20 Series User’s Guide 1-3 Lucent TURN-UP The CellPipe 20 Series Product Family supports the Lucent TURN-UP™ automated CPE provisioning system. TURN-Up is enabled when a user powers up his unit and allows service providers to quickly and efficiently distribute a...
Page 11 - Setup; Verifying package contents
CellPipe™ 20 Series User’s Guide 2-1 2 Setup Prior to setting up your unit, verify the contents of the package for your unit against the package-contents list provided in this chapter. After determining the contents are complete, connect the cables, verify all status lights are operating properly, a...
Page 14 - Checking status lights; Console setup
SetupChecking status lights 2-4 CellPipe™ 20 Series User’s Guide Checking status lights Observe the activity pattern of the lights at the front of the CellPipe units to verify that they are connected properly. Figure 2-3. Status lights When all the cables are connected, verify that: • The pwr light ...
Page 17 - Command-Line Interface; Syntax of command-line interface
CellPipe™ 20 Series User’s Guide 3-1 3 Command-Line Interface CellPipe 20 Series units are managed through a command-line interface (CLI). You set up a connection between your computer and the unit and use VT100 emulation software to display configuration information on your computer and input comma...
Page 18 - Using the commands; Viewing the main menu; Displaying information about a command
Command-Line InterfaceUsing the commands 3-2 CellPipe™ 20 Series User’s Guide Using the commands The CLI of the CellPipe 20 Series consists of two hierarchical levels. Some of the second-level commands display values or status of the selected commands from the main level. Note: Access to the CLI is ...
Page 19 - Returning to the main menu; Displaying second-level commands; Bridging commands
Command-Line Interface Bridging commands CellPipe™ 20 Series User’s Guide 3-3 Returning to the main menu To return to the main commands, enter the home command: > lan> home Displaying second-level commands To select a second-level command, enter the command at the > prompt: >adsl> sho...
Page 22 - Routing commands
Command-Line InterfaceRouting commands 3-6 CellPipe™ 20 Series User’s Guide Routing commands You have to preselect for routing mode to have the routing commands display. To select for routing, enter the mode command and then enter r to select routing. >>mode Please select bridge or router:(b/r...
Page 27 - Configuring a 20 Series CellPipe
CellPipe™ 20 Series User’s Guide 4-1 4 Configuring a 20 Series CellPipe This chapter provides general information for configuration of the various interfaces and procedures for administering a CellPipe 20 Series unit. Auto-provisioning All CellPipe 20 Series units support the Lucent TURN-UP automate...
Page 28 - Configuring WAN interface; SDSL commands and configurations
Configuring a 20 Series CellPipeConfiguring WAN interface 4-2 CellPipe™ 20 Series User’s Guide When you power up the unit, it is set to default (factory settings) and the console will display the following message: Starting to download from remote server... This means TURN-UP is enabled and is downl...
Page 30 - ADSL commands and configurations
Configuring a 20 Series CellPipeConfiguring WAN interface 4-4 CellPipe™ 20 Series User’s Guide >sdsl> smbit <Normal|Reverse> Select the status command to display the configuration and status of the current SDSL setting. For example: >sdsl> status >version : Ver 2.31 Date 19/Feb/...
Page 33 - Configuring LAN interface; Configuring LAN interface in bridging mode
Configuring a 20 Series CellPipe Configuring LAN interface CellPipe™ 20 Series User’s Guide 4-7 AS0_Dn_Latency_Actual <interleave> LS0_Up_Bytes_Actual 0 LS0_Up_Latency_Actual <interleave> Fast_R_Up_Actual 0 Interleave_S_Up_Actual 0 Interleave_D_Up_Actual 0 Interleave_R_Up_Actual 0 Fast_R...
Page 34 - Configuring LAN interface in routing mode
Configuring a 20 Series CellPipeConfiguring LAN interface 4-8 CellPipe™ 20 Series User’s Guide fullduplex - fullduplex <Disable>|<Enable> setip - setup the IP address, and subnet mask for Ethernet connection show - show LAN configuration Select the fullduplex command to enable or disable...
Page 35 - Configuring the manage command; Configuring the mode command
Configuring a 20 Series CellPipe Configuring the manage command CellPipe™ 20 Series User’s Guide 4-9 Select the dhcpserver command to configure the range of IP addresses that are associated with the subnet mask used for the DHCP server. >lan> dhcpserver <range1 startIP> <range1 endIP&...
Page 36 - Configuring the quick command; The quick command in bridging mode; The quick command in routing mode
Configuring a 20 Series CellPipeConfiguring the quick command 4-10 CellPipe™ 20 Series User’s Guide >>mode Please select bridge or router:(b/r,r) <b|r> Configuring the quick command The quick command allows you to easily configure your LAN connections in either the bridging or routing mo...
Page 37 - Configuring the r1483 command; The r1483 command in bridging mode
Configuring a 20 Series CellPipe Configuring the r1483 command CellPipe™ 20 Series User’s Guide 4-11 >>quick R1483(r)/ IPoA(i)/ PPPoA(p): ipoa 0 PVC existed, 8 PVCs available. Ethernet IP (149.198.65.46) : Subnet mask (255.255.255.0) : VPI(0-1023): 5 VCI(1-65535): 33 WAN IP : 148.198.6.46 Gate...
Page 38 - The r1483 command in routing mode
Configuring a 20 Series CellPipeConfiguring the r1483 command 4-12 CellPipe™ 20 Series User’s Guide setspan - <Enable>|<Disable> spanning tree show - show RFC1483 configuration Select the delpvc command to delete one or all PVCs. >r1483> delpvc <all>|[<vpi>/]<vci>...
Page 39 - Configuring the dnsrelay command
Configuring a 20 Series CellPipe Configuring the dnsrelay command CellPipe™ 20 Series User’s Guide 4-13 Select the setwanip command to set PVC and the IP address for routing. >r1483> setwanip [<vpi>/]<vci> <wanip[/<masknum>]> Select the show command to display the RFC14...
Page 40 - Configuring the pppoa command
Configuring a 20 Series CellPipeConfiguring the pppoa command 4-14 CellPipe™ 20 Series User’s Guide Select the setqos command to set the class for quality of service. >ipoa> setqos [<vpi>/]<vci> <ubr|cbr|vbr(nrt)> Select the setrip command to set the PVC for RIP. >ipoa>...
Page 41 - Configuring the pat command
Configuring a 20 Series CellPipe Configuring the pat command CellPipe™ 20 Series User’s Guide 4-15 Confirm Password again: ****** Pass has been changed Select the deluser command to delete a user of a pppoa connection. >pppoa> deluser Select the echo command to input the echo time interval and...
Page 43 - Upgrading System Software; Preparing to upgrade
CellPipe™ 20 Series User’s Guide 5-1 5 Upgrading System Software Preparing to upgrade To upgrade system software for a CellPipe 20 Series unit, you need to download to your computer the appropriate zipped file of the latest software release. Establish a serial connection between the unit and your co...
Page 44 - Upgrading software
Upgrading System SoftwareUpgrading software 5-2 CellPipe™ 20 Series User’s Guide Upgrading software Follow the procedure below to upgrade software: 1 Extract the loads from eSight to your computer. 2 Establish an Ethernet connection between the unit and your computer. 3 Set up IP addresses on the un...
Page 45 - Warranties and FCC Regulations; Product warranty
CellPipe™ 20 Series User’s Guide A-1 Warranties and FCC Regulations Product warranty 1 Lucent Technologies warrants that the CellPipe unit will be free from defects in material and workmanship for a period of twelve (12) months from date of shipment. 2 Lucent Technologies shall incur no liability un...
Page 46 - Warranty repair; FCC Part 15 Notice
Warranties and FCC RegulationsFCC Part 15 Notice A-2 CellPipe™ 20 Series User’s Guide BUSINESS RELATIONS. THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES. Warranty repair 1 During the first three (3) months of ownership, Lucent Technologies will repair or replace a defective product covered under w...