Page 2 - To order a FREE Lennox; Operation Warnings; All parts of your Lennox; Table of Contents; Safety and Your Fireplace; FREE; SAFETY; OFFER; The Lennox; To receive your FREE; SAFETY GUARD
2 Safety and Your Fireplace To prevent severe burns and injuries, install a screen or physical barrier to prevent direct contact with the glass. To order a FREE Lennox ® SAFETY GUARD for your fireplace, see details at left. Follow the safety instructions below and be sure everyone in your househ...
Page 3 - Les surfaces de votre foyer deviennent; Toutes les parties de votre foyer; SAFETY GUARD GRATIS; ¡Las superficies de la chimenea se ponen; ¡Todas las partes de la chimenea; Seguridad y
3 Afin d'éviter de vous brûler gravement ou de vous blesser, installez une grille ou une barrière physique pour empêcher tout contact direct avec la vitre. Pour commander un PANNEAU DE PROTECTION Lennox ® GRATUIT pour votre foyer, consultez les détails dans la partie gauche. Suivez les instructi...
Page 5 - Figure A
5 APPOSITION DES MISES EN GARDE RELATIVES à LA SÉCURITÉ D’UTILISATION Votre foyer a été livré avec des étiquettes de sécurité qui doivent être collées à côté des dispositifs de contrôle du foyer. Une étiquette de sécurité devrait être collée sur la plaque de l’interrupteur contrôlant l’allumage du f...
Page 6 - General Information; Millivolt; WARNING; AND MAINTENANCE; Carbon Monoxide Poisoning:; OPERATION
6 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. General Information The Millivolt appliances have a millivolt gas control valve with piezo ignition system. The Electronic appliances have an electronic intermittent pilot ignition system. External electrical power is required to operate these u...
Page 7 - Table; Tables 3 and 4; Table 3; Figure 2; Table 5; Cleaning Glass
7 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Millivolt Models - BTU Input Millivolt models come standard with the manually-modulated gas valve; flame appear- ance and heat output can be controlled at the gas valve. Input of for these models is shown in Table 1. Electronic Models - Electron...
Page 8 - Millivolt Appliances - Appliances with; Figure; instructions may also be found on the pull out; To prevent excessive resistance in burner; Gas Control Compartment Access; OPERATION AND CARE OF YOUR APPLIANCE; same room as the appliance. Toddlers, young children and others; AVERTISSEMENT; risque d’avoir accès à la pièce et aux surfaces chaudes.; Gas Controls/Control Compartment Access; Figure 1
8 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. On millivolt systems, the piezo igniter, HI/LO flame adjustment knob, and pilot and main gas OFF/ON control knob are located below the glass panel enclosure. The gas valve for electronic systems is also located below the glass enclosure panel. S...
Page 9 - - SIT Millivolt Gas Valve; Note: The piezo igniter is located below; Figure 4 - Spill Switch
9 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. HI LO W HT PT HT PT PILO T PIL OT ON it OFF IN OUT Manifold Pressure Tap Inlet Pressure Tap Pilot Adjustment Screw HI/LO Variable Flame Height Adjustment Main Gas Control Knob OFF/PILOT/ON Figure 2 - SIT Millivolt Gas Valve TPTH TP TH Main Gas C...
Page 10 - Do not operate the shutoff lever; Glass Front; Outside Air Control Lever; Outside Combustion Air Controls; Figure 5
10 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. WARNING Do not operate the shutoff lever unless a complete outside com- bustion air system has been installed with your appliance. Glass Front Figure 5 Control Compartment Access Panel Outside Air Control Lever with Stop Behind Securing Screw O...
Page 11 - Turn off gas and electrical power
11 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. MAINTENANCE (See Maintenance Schedule, Page 26) Refer to the maintenance schedule for main- tenance tasks, procedures, frequency and by whom they should be performed. Always verify proper operation of the appliance after servicing. WARNING Turn...
Page 12 - Figure 6
WARNINGS • DO NOT attempt to install the logs until the appliance instal- lation has been completed, the gas line connected and tested for leaks and the initial burner operation has been checked out. • The size and position of the log set was engineered to give the appliance a safe, reliable and att...
Page 13 - LOG SET; LOG SET - IDENTIFICATION; REFERENCE; Top View of Logs; Glowing Embers; Top View of Logs - Installed; Figure 7
13 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. LOG SET Catalog Number H3210 * Item Description A Log, Center B Log, Left Rear C Log, Left Front D Log, Right Rear E Log, Top Center F Log, Front Center * Item "letters" above correspond to photos on right LOG SET - IDENTIFICATION REFER...
Page 14 - Figure 9; READ LOG WARNINGS ON; ment Access Instructions; Position The Groove in The Back of Log (C); Figure 8
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Position The Groove At The Bottom Of Log (A) Over The Grate And Slide It Forward Against The Grate Here Figure 9 READ LOG WARNINGS ON PAGE 12 BEFORE PROCEEDING 1. Remove front glass enclosure panel from appliance. a. Open Control Compartment Acces...
Page 15 - Figure 15 - Burner Flame Appearance
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 15 Position round end of log (E) against the notch of log (D) here. Two charred spots face the front Figure 13 10. Place Log (E) as shown in Figure 13. BURNER ADjUSTMENTS (QUALIFIED TECHNICIANS ONLY) Flame Appearance and Sooting Proper flame appea...
Page 16 - Burner Air Shutter Adjustment Procedure; WARNINGS; - Electronic Pilot Assembly
16 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Ref. Air shutter Patent: U.S. Pat. 5,553,603 Adjustment Rod Positions (when viewed from above) Figure 16 Main Burner Factory Air Shutter Opening Setting - All Models Model Natural Gas Propane Gas MPB35ST 1/8” 3.2mm 1/4” 6.4mm Increase Shutter O...
Page 17 - WIRING DIAGRAMS; WARRANTY; LENNOX HEARTH PRODUCTS; PRODUCT REFERENCE INFORMATION; Spill Switch; tation Only
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 17 WIRING DIAGRAMS Wiring diagrams are provided here for reference purposes only. This information is also provided on schematics attached directly to the appliance on a pullout panel located within the control compartment. CAUTION: LABEL ALL WIRE...
Page 19 - Screen Heat Guard Kit; cannot; ACCESSORY COMPONENTS
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 19 Screen Heat Guard Kit This easy to install optional screen heat guard installs over the standard glass enclosure panel to prevent contact with the hot glass surface. These screen heat guard panels cannot be used in conjunction with the arch doo...
Page 21 - Sunrise Style; The brickaded liner kits include ceramic panels; Decorative Grille Kits; face of the appliance in place of the standard louvers.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 21 H3541 CUGK35C 35” Black UPPER GRILLE KITS CRESCENTS H3543 CUGK35SP 35” Satin Pewter H3569 SLGK35C 35” Black LOWER GRILLE KITS SUNRISE H3571 SLGK35SP 35” Satin Pewter Cat. No. # Model Description Model Series H3565 SUGK35C 35” Black UPPER GRILLE...
Page 22 - LIGHTING INSTRUCTIONS – MILLIVOLT GAS VALVE; FOR YOUR SAFETY READ BEFORE LIGHTING; Knob cannot be turned from “PILOT” to “OFF”
22 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 6. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information above (to the left) on this label. If you don’t smell gas, go to the next step. 7. Push in...
Page 23 - INSTRUCTIONS D’ALLUMAGE – VANNE GAZ MILLIVOLT; INSTRUCTIONS D'ALLUMAGE; POUR FERMER LE GAZ QUI ALIMENTE L’APPAREIL; SIT Vanne Gaz Millivolt
23 REMARQUE : LES SCHÉMAS ET LES ILLUSTRATIONS NE SONT PAS À L’ÉCHELLE INSTRUCTIONS D’ALLUMAGE – VANNE GAZ MILLIVOLT INSTRUCTIONS D'ALLUMAGE 8. Enfoncez le bouton de réglage jusqu’au fond et gardez-le enfoncé. Allumez immédiatement la veilleuse en déclenchant l’allume-gaz à étincelle (en poussant le...
Page 24 - OPERATING INSTRUCTIONS — ELECTRONIC; Honeywell Electronic Gas Control Valve; RESULT CAUSING PROPERTY DAMAGE, PERSONAL INjURY OR LOSS OF LIFE.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 24 A. This appliance is equipped with an ignition device which automatically lights the pilot. Do not try to light the pilot by hand. B. BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell next to the floor because some ...
Page 25 - INSTRUCTIONS D’ALLUMAGE — ELECTRONIC; INSTRUCTIONS DE MISE EN MARCHE; Interrupteur ON / OFF
25 REMARQUE : LES SCHÉMAS ET LES ILLUSTRATIONS NE SONT PAS À L’ÉCHELLE INSTRUCTIONS D’ALLUMAGE — ELECTRONIC INSTRUCTIONS DE MISE EN MARCHE POUR PLUS DE SÉCURITÉ LIRE AVANT DE METTRE EN MARCHE A. Cet appareil est muni d’un dispositif d’allumage qui allume automatiquement la veilleuse. Ne tentez pas d...
Page 26 - Annually (Before the onset of the Burning Season)
26 MAINTENANCE TASK ACCOMPLISHING PERSON PROCEDURE Inspect/Clean Burner, Logs and Controls Qualified Service Technician Inspect valve and ensure it is properly operating. Check piping for leaks. Vacuum the control compartment, fireplace logs and burner area. Check Flame Patterns and Flame Height Qua...
Page 27 - TROUBLESHOOTING GUIDE - ELECTRONIC IGNITION SYSTEM; TROUBLESHOOTING THE MILLIVOLT CONTROL SYSTEM
27 Note: Before troubleshooting the gas control system, Ensure external gas shut off valve, located at gas supply inlet, (and wall switch, iff applicable), is in the “ON” position. Important: Valve system troubleshooting should only be accomplished by a qualified service technician. SYMPTOM POSSIBLE...
Page 28 - TROUBLESHOOTING THE ELECTRONIC IGNITION SYSTEM
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 28 START CHECK • Turn Off Gas Supply.• Ensure Valve Switch Is In ON Position.• Disconnect Control Harness.• Set Thermostat To Call For Heat. • Check for proper volt- age at control harness (see insert A). Voltage should be 24V between thermostat o...
Page 29 - REPLACEMENT PARTS LIST - MPB35ST; can result in poor performance and safety hazards.
29 Item Part/Cat. No. Qty Description Where Used SIT Millivolt Only 1 H3357 1 Gas Train Assembly, NG, MV MPB35ST-NM 1 H3355 1 Gas Train Assembly, LP, MV MPB35ST-PM Honeywell Electronic Only 2 H3356 1 Gas Train Assembly, NG, Elecrtr. MPB35ST-NE 3 H4977 1 Transformer MPB35ST-NE & MPB35ST-PE Misc. ...
Page 30 - REPLACEMENT PARTS - MPB35ST
30 14 Note: Ordering information for Volcanic Stone, Glowing Embers and Touch-up Paint can be found on Page 16 3 13 5 4 20 16 21 9 15 7 17 9 15 7 10 12 18 19 11 2 22 8 23 24 8 1 22 6 * Electrical Outlet Kit consists of a junction box, 2 screws, an receptacle outlet, an OFF/ON rocker switch and a sna...