Page 2 - Table of Contents
CV-M30 Table of Contents 1. General ........................................................................................................ 2 2. Standard Composition ...................................................................................... 2 3. Main Features ..............................
Page 3 - Standard Composition
CV-M30 1. General The CV-M30 camera revision D is an updated version with a new CCD sensor ICX-418ALL-6 with improved specifications. The revision D camera can only operate in double speed. CV-M30 is a monochrome CCD video camera designed for industrial video sensing applications. The camera operate...
Page 4 - Locations and Functions
CV-M30 4. Locations and Functions Fig. 1. Locations 1. 1/2” interline-transfer type CCD sensor 2. Lens mount for C-mount lenses. *1) 3. BNC connector for video output 4. Switch block SW1 for shutter speed and function mode setting 5. 6-Pin connector for Input/output of control signals 6. 12-Pin conn...
Page 5 - Signal; EEN Output; GND
CV-M30 5. Pin Assignment 5.1. 12-pin Multi-connector (DC-IN/VIDEO OUT, EXT.HD/VD IN) Type: HR10A-10R-12PB-01 (Hirose) male Seen from rear. Fig. 2. 12 pin connector 5.2. 6-pin Multi-connector (TRIGGER) Type: HR10A-7R-6PB (Hirose) male Pin no Signal Remarks 1 GND 2 +12 V DC input 3 GND 4 Video output ...
Page 7 - Functions and Operations; SW1-7 to OFF for normal shutter
CV-M30 6. Functions and Operations 6.1. Input of External HD/VD Signals As factory setting the camera can be synchronized by external HD/VD signals. The external supplied HD/VD signal should follow the same standard as the camera setting for speed, scanning and interlace. The signal level must be 4....
Page 10 - Full
CV-M30 6.4. Other Functions 6.4.1. Double Speed Mode The CV-M30 camera revision D operates only with double speed scanning. Double speed is 120 fields per second. (V= 119.88Hz. H=31.468 kHz). To use this mode. Set: 6.4.2. Partial Scanning Mode To obtain a higher frame rate, the partial scanning can ...
Page 13 - Fig. 15. Vertical timing for pulse width control
CV-M30 6.5.6. Pulse Width Control H = 31.778 µ s Fig. 15. Vertical timing for pulse width control 6.5.7. Pulse Width. Partial Scan H = 31.778 µ s Fig. 16. Vertical timing for pulse width control 1/2 partial scanning H = 31.778 µ s Fig. 17. Vertical timing for pulse width control 1/3 partial scanning...
Page 16 - Internal Switch and Jumper Settings; Gamma
CV-M30 7.2. Internal Switch and Jumper Settings Inside the camera there are switches for 75 termination of external trigger/VD and HD and for trigger mode select. There are also jumpers for gamma select. 7.2.1. Trigger/VD and HD Termination On the PK8212 board switch SW1 for 75 Ohm termination of ex...
Page 17 - Internal Adjustments of Video Signal; VR2 is for black level set-up. Factory setting is 20 mVpp
CV-M30 8. Internal Adjustments of Video Signal For adjustment of the video output signal there are internal potentiometers on th PK 7987A board. Adjustment should only be done in a setup with a standard test chart and controlled illumination Do not touch these potentiometers unless you are familiar ...
Page 18 - External Appearance and Dimensions
CV-M30 9. External Appearance and Dimensions Fig. 22. Outline - 17 -
Page 21 - DECLARATION OF CONFORMITY; AS DEFINED BY THE COUNCIL DIRECTIVE
CV-M30 12. Users Record Camera type: CV-M30 Revision: (Revision D) Serial No. …………….. For camera revision history, please contact your local JAI distributor. Users Mode Settings. Users Modifications. DECLARATION OF CONFORMITY AS DEFINED BY THE COUNCIL DIRECTIVE 89/336/EEC EMC (ELECTROMAGNETIC COMPAB...