Page 2 - Installers Guide; DO NOT; Owners Guide; ALERTED; SAFETY AND WARNING INFORMATION
Heat & Glo • SL-350TRS-C, SL-550/750TRS-IPI-D • 2065-985 Rev. J • 5/06 2 These units MUST use one of the vent systems described in the Installing the Appliance section ofthe Installers Guide . NO OTHER vent systems or components MAY BE USED. This gas appliance and vent assembly MUST be vented di...
Page 3 - TABLE OF CONTENTS
Heat & Glo • SL-350TRS-C, SL-550/750TRS-IPI-D • 2065-985 Rev. J • 5/06 3 TABLE OF CONTENTS Safety and Warning Information ......................................................... 2 Service Parts Lists ................................................................................. 4 Section 1:...
Page 4 - Service Parts; Part number list on following page.; Log Set Assembly
Heat & Glo • SL-350TRS-C, SL-550/750TRS-IPI-D • 2065-985 Rev. J • 5/06 4 (NG, LP) Exploded Parts Diagram Service Parts SL-350TRS-C Beginning Manufacturing Date: 4-01 Ending Manufacturing Date: ______ Part number list on following page. 1 3 6 2 3 4 5 7 Log Set Assembly 1 2 8 11 1 0 9 1 4 1 5 1
Page 6 - Beginning Manufacturing Date:; Standing Pilot Ignition
Heat & Glo • SL-350TRS-C, SL-550/750TRS-IPI-D • 2065-985 Rev. J • 5/06 6 (NG, LP) Exploded Parts Diagram Service Parts Beginning Manufacturing Date: 4-01 Ending Manufacturing Date: ______ SL-350TRS-C ITEM DESCRIPTION SERIAL # PART NUMBER 1 Piezo Ignitor 291-513 2 Burner Neck Gasket 2045-407 3 Th...
Page 8 - supply serial and model numbers to ensure correct service parts.; ACCESSORIES
Heat & Glo • SL-350TRS-C, SL-550/750TRS-IPI-D • 2065-985 Rev. J • 5/06 8 (NG, LP) Service Parts List IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When ordering, supply serial and model numbers to ensure correct service parts. SL-550TRS-I...
Page 11 - Intermittent Pilot Ignition
Heat & Glo • SL-350TRS-C, SL-550/750TRS-IPI-D • 2065-985 Rev. J • 5/06 11 (NG, LP) Exploded Parts Diagram Service Parts Beginning Manufacturing Date: 4-04 Ending Manufacturing Date: ______ SL-750TRS-IPI-D, SL-550TRS-IPI-D ITEM / PIÈC E DESCRIPTION SERIAL # / N° DE SÉRIE PART NUMBER / N° DE PIÈCE...
Page 12 - Appliance Certification; The Heat & Glo appliance models discussed in this; Certification; Underwriters Laboratories; High Altitude Installations
Heat & Glo • SL-350TRS-C, SL-550/750TRS-IPI-D • 2065-985 Rev. J • 5/06 12 1 Approvals andCodes Heat & Glo QualitySystems registeredby SGS ICS Appliance Certification The Heat & Glo appliance models discussed in this Installers Guide have been tested to certification standards and listed ...
Page 13 - The following requirements reference various; Requirements for the Commonwealth of
Heat & Glo • SL-350TRS-C, SL-550/750TRS-IPI-D • 2065-985 Rev. J • 5/06 13 For all side wall horizontally vented gas fueled equipmentinstalled in every dwelling, building or structure used inwhole or in part for residential purposes, including thoseowned or operated by the Commonwealth and where ...
Page 14 - Getting Started; Introducing the Heat & Glo Gas Appliances; Pre-install Preparation; Do not install any
Heat & Glo • SL-350TRS-C, SL-550/750TRS-IPI-D • 2065-985 Rev. J • 5/06 14 2 Getting Started Introducing the Heat & Glo Gas Appliances Heat & Glo direct vent gas appliances are designed to op-erate with all combustion air siphoned from outside of thebuilding and all exhaust gases expelled...
Page 15 - GASS LINE
Heat & Glo • SL-350TRS-C, SL-550/750TRS-IPI-D • 2065-985 Rev. J • 5/06 15 Figure 1. Diagram of the SL-750TRS-IPI-D HOOD GAS CONTROLS GAS LINE ACCESS VENT COLLARS TOP STANDOFFS ELECTRICAL ACCESS RATING PLATES & LABELS BOTTOM GRILLE COVER CERAMIC FIBER PAD 37-7/8 962 [ ] 3-9/16 90 [ ] 6-7/8 17...
Page 18 - Installing the Appliance; Step 1. Locating the Appliance; Vertical Sections; Constructing the Appliance Chase
Heat & Glo • SL-350TRS-C, SL-550/750TRS-IPI-D • 2065-985 Rev. J • 5/06 18 3 Installing the Appliance Step 1. Locating the Appliance Space and clearance requirements for locating a appliancewithin a room (see Figure 4). Minimum Clearances from the Appliance to Combustible Materials For minimum cl...
Page 19 - Framing Dimensions; Step 2. Framing the Appliance
Heat & Glo • SL-350TRS-C, SL-550/750TRS-IPI-D • 2065-985 Rev. J • 5/06 19 Figure 5. Framing Dimensions Framing should beconstructed of 2 X 4lumber or heavier. The framing headersmay rest on theappliance stand-offs. Step 2. Framing the Appliance Appliance framing can be built before or after the ...
Page 22 - Step 3. Installing the Vent System; vent collars. This pipe is tested and; Vent System Termination Kits; Identifying Vent Components; . Detailed installation instructions
Heat & Glo • SL-350TRS-C, SL-550/750TRS-IPI-D • 2065-985 Rev. J • 5/06 22 ! Figure 8. Vent System Components and Termination Kits Step 3. Installing the Vent System A. Vent System Approvals These models have vent starting collars on both the topand the back of the unit. Depending upon the instal...
Page 23 - Flex Vent; ELBOWS; For vertical venting; CAP; STRAIGHT OUT HORIZONTAL VENTING; Figure 11. Straight Out Horizontal Venting; elbows for corner installations.
Heat & Glo • SL-350TRS-C, SL-550/750TRS-IPI-D • 2065-985 Rev. J • 5/06 23 90-DEGREE ELBOWS Figure 9. Flex Vent The flex vent must be supported with the spacing betweensupport intervals not exceeding 4 feet, with no more than ½inch sag between supports. A support is required at each change in ven...
Page 24 - ELBOW NATURAL GAS
Heat & Glo • SL-350TRS-C, SL-550/750TRS-IPI-D • 2065-985 Rev. J • 5/06 24 V H 1' MIN. (305mm) 2' MAX. (610mm) 2' MIN. (610mm) 4' MAX. (1.22m) 3' MIN. (914mm) 6' MAX. (1.86m) 4' MIN. (1.22m) 8' MAX. (2.4m) V+H=40' MAX. (12.4m) H = 8' MAX. (2.4m) Figure 12. Venting with One 90° Elbow Figure 13. Ve...
Page 25 - Figure 14. Venting with Two 90° Elbows; H + H
Heat & Glo • SL-350TRS-C, SL-550/750TRS-IPI-D • 2065-985 Rev. J • 5/06 25 V H H + H 1 1' MIN. (305 mm) 2' MAX. (610 mm) 4' MAX. (1.22m) 2' MIN. (610 mm) 4' MAX. (1.22 m) 8' MAX. (2.4m) 3' MIN. (914 mm) 6' MAX. (1.86 m) 12' MAX. (3.6m) 4' MIN. (1.22 m) 8' MAX. (2.48 m) 16' MAX. (4.8m) V+H+H 1 = 4...
Page 26 - Figure 15. Venting with Two 90° Elbows; ELBOWS NATURAL GAS
Heat & Glo • SL-350TRS-C, SL-550/750TRS-IPI-D • 2065-985 Rev. J • 5/06 26 Figure 15. Venting with Two 90° Elbows Use SL D-Series components only. VENTING WITH TWO (2) 90 o ELBOWS NATURAL GAS H + H 1 MAX. = 16 FT (4.8m) V + H + H 1 MAX. = 40 FT (12.2m) MODELS: SL-550TRS-D, SL-750TRS-D H + H 1 (MA...
Page 27 - Figure 16. Venting with Two 90° Elbows
Heat & Glo • SL-350TRS-C, SL-550/750TRS-IPI-D • 2065-985 Rev. J • 5/06 27 Figure 16. Venting with Two 90° Elbows Use SL D-Series components only. H V V 1 VENTING WITH TWO (2) 90 o ELBOWS NATURAL GAS H MAX. = 16 FT (4.8m) V + V 1 + H MAX. = 40 FT (12.2m) MODELS: SL-550TRS-D, SL-750TRS-D H (MAX.) ...
Page 28 - Figure 17. Venting with Three 90° elbows; V H H + H
Heat & Glo • SL-350TRS-C, SL-550/750TRS-IPI-D • 2065-985 Rev. J • 5/06 28 Figure 17. Venting with Three 90° elbows 1' MIN. (305 mm) 2' MAX. (610mm) 4' MAX. (1.22m) 2' MIN. (610 mm) 4' MAX. (1.22m) 8' MAX. (2.48m) 3' MIN. (914 mm) 6' MAX. (1.86m) 12' MAX. (3.72m) 4' MIN. (1.22 m) 8' MAX. (2.48m) ...
Page 29 - Figure 18. Venting with three 90° elbows
Heat & Glo • SL-350TRS-C, SL-550/750TRS-IPI-D • 2065-985 Rev. J • 5/06 29 Figure 18. Venting with three 90° elbows Use SL D-Series components only. VENTING WITH THREE (3) 90 o ELBOWS NATURAL GAS VENTING WITH THREE (3) 90 o ELBOWS PROPANE V + H + V 1 + H 1 MAX. = 40 FT (12.2m) V + H + V 1 + H 1 M...
Page 30 - Figure 19. Venting with three 90° elbows
Heat & Glo • SL-350TRS-C, SL-550/750TRS-IPI-D • 2065-985 Rev. J • 5/06 30 Use SL D-Series components only. Figure 19. Venting with three 90° elbows V1 H1 H V VENTING WITH THREE (3) 90 o ELBOWS NATURAL GAS H + H 1 MAX. = 16 FT (4.8m) V + V 1 + H + H 1 MAX. = 40 FT (12.2m) MODEL SL-750TRS-D H + H ...
Page 31 - Figure 20. Venting with Four 90° elbows
Heat & Glo • SL-350TRS-C, SL-550/750TRS-IPI-D • 2065-985 Rev. J • 5/06 31 Figure 20. Venting with Four 90° elbows VENTING WITH FOUR (4) 90° ELBOWS NATURAL AND PROPANE GAS V (MIN.) H (MAX.) 2' (609mm) 5' (1.52m) V 1 (MIN.) H 1 (MAX.) V 2 (MIN.) 5' (1.52m) 5' (1.52m) 4.5' (1.37m) V + V 1 + V 2 + H...
Page 32 - DVP Series Venting Only:; Go to Step 4 Install Firestops.
Heat & Glo • SL-350TRS-C, SL-550/750TRS-IPI-D • 2065-985 Rev. J • 5/06 32 ! Figure 21. Insert screwdriver or similar object here to remove cap. CUT HERE Venting Out Rear Venting Out Top ! WARNING: THE REAR VENT COLLAR SEALCAP MUST REMAIN ATTACHED TO THE REAR VENT COLLARS IF THE VENT SYSTEM IS AT...
Page 35 - For Horizontal Terminations -; For DVP Venting Only:; Figure 29. Trapezoid Termination Cap
Heat & Glo • SL-350TRS-C, SL-550/750TRS-IPI-D • 2065-985 Rev. J • 5/06 35 C. Vent Termination SL-Series Venting Only: For Horizontal Terminations - To attach and secure the termination to the last section of horizontal vent: • Rotate and interlock the ends as described at the begin- ning of the ...
Page 36 - = AREA WHERE TERMINAL IS NOT PERMITTED; Figure 30. Vent Termination Minimum Clearances; public; Alcove Applications
Heat & Glo • SL-350TRS-C, SL-550/750TRS-IPI-D • 2065-985 Rev. J • 5/06 36 V = VENT TERMINAL X = AIR SUPPLY INLET = AREA WHERE TERMINAL IS NOT PERMITTED Figure 30. Vent Termination Minimum Clearances A = 12" ....................... clearances above grade, veran- da, porch, deck or balcony B =...
Page 38 - Figure 33. Gas Control Systems; STANDING PILOT; Step 5. The Gas Control Systems; Standing Pilot Ignition and Intellifire Pilot Ignition (IPI).; Standing Pilot Ignition System; THE APPLIANCE JUNCTION BOX IN A IPI SYSTEM.
Heat & Glo • SL-350TRS-C, SL-550/750TRS-IPI-D • 2065-985 Rev. J • 5/06 38 Step 4. Positioning, Leveling, and Securing the Appliance • Place the appliance into position. • Level the appliance from side to side and from front to back. • Shim the appliance with non-combustible material, such as she...
Page 39 - Pressure
Heat & Glo • SL-350TRS-C, SL-550/750TRS-IPI-D • 2065-985 Rev. J • 5/06 39 • Insert insulation from the outside of the appliance and pack the insulation tightly to totally seal between thepipe and the outer casing. • At the gas line access hole the gap between the supply piping and gas access hol...
Page 40 - Step 8. Wiring the Appliance; This appliance
Heat & Glo • SL-350TRS-C, SL-550/750TRS-IPI-D • 2065-985 Rev. J • 5/06 40 Step 8. Wiring the Appliance NOTE: Electrical wiring must be installed by a licensedelectrician. CAUTION: DISCONNECT REMOTE CONTROLS IF AB-SENT FOR EXTENDED TIME PERIODS. THIS WILL PRE-VENT ACCIDENTAL APPLIANCE OPERATION. ...
Page 41 - Optional Accessories; WARNING; Incorrect wiring will damage millivolt valves.
Heat & Glo • SL-350TRS-C, SL-550/750TRS-IPI-D • 2065-985 Rev. J • 5/06 41 Figure 36. Intermittent Pilot Ignition (IPI) Wiring Diagram TRANSFORMER 3 VAC PLUG IN RE D BATTERY PACK THERMOSTAT WIRE A SSEMBLY JUMPER WIRE (TO BROWN) O RANG E GR E E N VALVE GROUND TO FIREPLACE CHASSIS WHITE ORANGE IGNI...
Page 42 - Hearth Extensions; require; Figure 39. Sealant Material; FINISH WALL MATERIAL MAY BE; Junction Box Diagram
Heat & Glo • SL-350TRS-C, SL-550/750TRS-IPI-D • 2065-985 Rev. J • 5/06 42 Step 9. Finishing Figure 38 shows the minimum vertical and correspondingmaximum horizontal dimensions of appliance mantels orother combustible projections above the top front edge ofthe appliance. See Figures 4 and 5 for o...
Page 43 - Figure 40. Glass Assembly
Heat & Glo • SL-350TRS-C, SL-550/750TRS-IPI-D • 2065-985 Rev. J • 5/06 43 Installing the Trim Combustible materials may be brought up to the specifiedclearances on the side and top front edges of the appliance,but MUST NEVER overlap onto the front face. The joints between the finished wall and t...
Page 44 - Step 11. Before Lighting the Appliance; Step 12. Lighting the Appliance
Heat & Glo • SL-350TRS-C, SL-550/750TRS-IPI-D • 2065-985 Rev. J • 5/06 44 Step 11. Before Lighting the Appliance Before lighting the appliance, be sure to do the following: Remove all paperwork from underneath the appliance. Review safety warnings and cautions • Read the Safety and Warning Infor...
Page 45 - Maintaining and Servicing Your Appliance; Appliance Maintenance; Placing Ember Material
Heat & Glo • SL-350TRS-C, SL-550/750TRS-IPI-D • 2065-985 Rev. J • 5/06 45 4 Maintaining and Servicing Your Appliance Appliance Maintenance Although the frequency of your appliance servicing and main-tenance will depend on use and the type of installation, youshould have a qualified service techn...