Page 2 - Congratulations; Listing Label Information/Location; Owner’s Manual; Read this manual before installing or operating this appliance.; Homeowner Reference Information; NATURAL
Heat & Glo • FB-IN, FB-GRAND • 783-908 Rev. J • 2/07 2 Congratulations Listing Label Information/Location Model Name: ___________________________________________ Date purchased/installed: __________________ Serial Number: __________________________________________ Location on appliance: ________...
Page 3 - Table of Contents
Heat & Glo • FB-IN, FB-GRAND • 783-908 Rev. J • 2/07 3 Table of Contents 1 Listing and Code Approvals A. Appliance Certi fi cation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 B. BTU Speci fi cations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 C. High Altitude In...
Page 4 - Note; Listing and Code Approvals; Vented Gas Appliance Heaters; Models; fl; WARNING; NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.
Heat & Glo • FB-IN, FB-GRAND • 783-908 Rev. J • 2/07 4 Note : To assure top performance, safety and ef fi ciency, inserts must be installed with an approved fl ue liner as per CAN/CGA B-149 or National Fuel Gas Code ANSI Z223 and these instructions. Note: This installation must conform with loca...
Page 5 - Getting Started; C. Inspect Appliance and Components; • Read all of the instructions before starting the insta-; CAUTION; Any such action may cause a
Heat & Glo • FB-IN, FB-GRAND • 783-908 Rev. J • 2/07 5 Heat & Glo gas inserts are designed for recessed installa-tions into solid fuel masonry or factory built non-combustible fi replaces that have been installed in accordance with the National, Provincial, State and local building codes. Pr...
Page 6 - Fireplace Size Requirements; A. Minimum Fireplace Opening; TOP VIEW
Heat & Glo • FB-IN, FB-GRAND • 783-908 Rev. J • 2/07 6 3 3 Fireplace Size Requirements A. Minimum Fireplace Opening Minimum fi replace opening requirements are shown in Figure 3.1. • The fi rebrick (refractory), glass doors, screen rails, screen mesh and log grates can be removed from a factory ...
Page 8 - A. Vent Termination Minimum Clearances; es minimum vent heights for various; Termination Locations
Heat & Glo • FB-IN, FB-GRAND • 783-908 Rev. J • 2/07 8 Fire Risk.Asphyxiation Risk. • Terminations MUST meet minimum clearances.• Exhaust gases are hot.• Nearby vents may draw fumes into house. A. Vent Termination Minimum Clearances Figure 4.1 speci fi es minimum vent heights for various pitched...
Page 9 - C. Measuring Standards; • Vertical terminations are measured to top of chimney.; B. Horizontal Venting; Horizontal venting is NOT allowed.; Vent Information and Diagrams; Symbol
Heat & Glo • FB-IN, FB-GRAND • 783-908 Rev. J • 2/07 9 CAUTION ALL vent speci fi cations MUST be followed. • This product is tested and listed to these speci fi cations. • Appliance performance will suffer if speci fi cations are not followed. Figure 5.1 C. Measuring Standards Vertical measureme...
Page 10 - Installation Preparation; D. Hearth or Hearth Extension; • Install gas line into
Heat & Glo • FB-IN, FB-GRAND • 783-908 Rev. J • 2/07 10 6 6 Installation Preparation Fire Risk.A hearth or hearth extension (if present) must comply with either of the following:• The solid fuel burning fi replace manufacturer’s speci fi cation. • Local building codes required by authority havin...
Page 11 - A. Venting Components; Installing Vent Pipe and Appliance; The vertical vent termination system installed on this model; B. Connecting Vent Pipe; Reference instructions in the termination kit.
Heat & Glo • FB-IN, FB-GRAND • 783-908 Rev. J • 2/07 11 A. Venting Components 7 7 Installing Vent Pipe and Appliance The vertical vent termination system installed on this model includes: • One 3-foot section stainless steel fl exible pipe (included with insert). • One length of 3-inch fl exible...
Page 12 - • Trim chimney top plate to minimize excess overhang or
Heat & Glo • FB-IN, FB-GRAND • 783-908 Rev. J • 2/07 12 Figure 7.2 CUT AND BEND FLASHING AS NEEDED TO FIT CHIMNEY SEALANT ADHESIVE • Trim chimney top plate to minimize excess overhang or bend over fl ue tile (see Figure 7.2). • Place 3/8 inch bead of 300º F silicone on fl ue tile top. C. Placing...
Page 13 - D. Installing Adaptor and Termination Cap; For installation of termination cap see minimum vent; Damper Flashing Kit; : Damper may have to be removed to use this kit.; system REQUIRES this insulation.; Masonry; OR
Heat & Glo • FB-IN, FB-GRAND • 783-908 Rev. J • 2/07 13 D. Installing Adaptor and Termination Cap For installation of termination cap see minimum vent heights for various pitched roofs (see Figure 7.2) . To install adaptor see Figure 7.3. Roof Pitch H (Min.) Ft.Flat to 6/12....................1....
Page 14 - Gas Information; ed technician using Hearth & Home Technologies; • If substituting for these components, please consult; Refer to; Reference Section 16; for location of gas line; Pressure
Heat & Glo • FB-IN, FB-GRAND • 783-908 Rev. J • 2/07 14 • Ensure that gas line does not come in contact with outer wrap of appliance. Follow local codes. • Incoming gas line should be piped into the valve compartment and connected to the 1/2 inch connection on the manual shutoff valve. • Check a...
Page 15 - HIGH ALTITUDE INSTALLATIONS; • A small amount of air will be in the gas supply lines.
Heat & Glo • FB-IN, FB-GRAND • 783-908 Rev. J • 2/07 15 Fire hazard. Do NOT change the valve settings.• This valve has been preset at the factory.• Changing valve settings may result in fi re hazard or bodily injury. HIGH ALTITUDE INSTALLATIONS U.L. Listed gas appliances are tested and approved ...
Page 16 - A. Wiring the Appliance; Electrical Information; National Electric Code ANSI/NFPA 70-latest; • An ON/OFF switch is included with appliance and should; Appliance Requirements; • This appliance DOES NOT require 110-120 VAC to
Heat & Glo • FB-IN, FB-GRAND • 783-908 Rev. J • 2/07 16 A. Wiring the Appliance 9 9 Electrical Information Note : This appliance must be electrically wired and grounded in accordance with local codes or, in the absence of local codes, with National Electric Code ANSI/NFPA 70-latest edition or th...
Page 17 - B. Junction Box Installation; Optional Accessories; replace. Place the outlet in the lower, back corner of
Heat & Glo • FB-IN, FB-GRAND • 783-908 Rev. J • 2/07 17 B. Junction Box Installation Figure 9.2 Junction box installation JUNCTION BOX SIDEWALL FEED PLUG THROUGH HOLE INSERT STRAIN RELIEF AROUND CORD IN THIS END FROM OUTSIDE OF UNIT SCREW PROVIDED Optional Accessories Connecting the electrical j...
Page 19 - A. Mantel Projections; Finishing; B. Installing Trim Surrounds; MUST NEVER
Heat & Glo • FB-IN, FB-GRAND • 783-908 Rev. J • 2/07 19 A. Mantel Projections Figure 10.1 shows the minimum vertical and corresponding maximum horizontal dimensions of appliance mantels or other combustible projections above the top front edge of the appliance, not the surround. 10 10 Finishing ...
Page 20 - Appliance Setup; A. Remove Shipping Materials; Remove shipping materials from inside or underneath the; B. Clean the Appliance; rebox or underneath in the control cavity.; Placing the Ember Material; • Place Mystic Ember over burner surface and around
Heat & Glo • FB-IN, FB-GRAND • 783-908 Rev. J • 2/07 20 Figure 11.1 Placement of Embers EMBER MATERIAL (TOP SURFACE, AND FRONT) BURNER PAN AIR SHUTTER 11 11 Appliance Setup A. Remove Shipping Materials Remove shipping materials from inside or underneath the fi rebox. B. Clean the Appliance Clean...
Page 21 - Logs are fragile! Carefully remove the logs from the packaging.
Heat & Glo • FB-IN, FB-GRAND • 783-908 Rev. J • 2/07 21 Log Set Assembly: LOGS-CFXGB E. Positioning the Logs This model uses locating tabs to positively locate the logs with respect to the grate assembly. Please refer to grate assembly. LOG NUMBER 1 (SRV768-701): Place log #1 onto the grate. Pus...
Page 23 - STRUCTIONS; Carefully remove the logs from the packaging.; GRATE ASSEMBLY; Push log back until it rests against locating tabs A and B.
Heat & Glo • FB-IN, FB-GRAND • 783-908 Rev. J • 2/07 23 LOG PLACEMENT IN- STRUCTIONS Carefully remove the logs from the packaging. CAUTION: Logs are fragile! 773-936 3/03 GRATE ASSEMBLY This model uses locating tabs to positively locate the logs with respect to the grate assembly. Please refer t...
Page 25 - Removing Glass Assembly; • To release glass assembly, pull latch forward and allow; Replacing Glass Assembly; G. Air Shutter Setting; Optimal; NG; Full open
Heat & Glo • FB-IN, FB-GRAND • 783-908 Rev. J • 2/07 25 Figure 11.16 Glass Assembly F. Glass Assembly Removing Glass Assembly There are two glass latches on the bottom of glass assembly. • To release glass assembly, pull latch forward and allow to retract away from glass assembly. • Remove glass...
Page 26 - A. Before Lighting Appliance; This appliance has a Standing Pilot Ignition.; Operating Instructions
Heat & Glo • FB-IN, FB-GRAND • 783-908 Rev. J • 2/07 26 Fire Risk.Explosion Risk.Gas may build up while lighting pilot.• Remove glass assembly before lighting pilot.• Replace glass assembly after lighting pilot. A. Before Lighting Appliance This appliance has a Standing Pilot Ignition. Before op...
Page 27 - B. Lighting Appliance; Standing Pilot Ignition; NOT FOR USE; Also Certi; WHAT TO DO IF YOU SMELL GAS
Heat & Glo • FB-IN, FB-GRAND • 783-908 Rev. J • 2/07 27 B. Lighting Appliance Standing Pilot Ignition 1. Turn off all electric power to the appliance if service is to be performed. 2. Open control access panel. 3. Move switch to “OFF” position. 4. Push in gas control knob slightly and turn clock...
Page 28 - C. Check Pilot Flame Appearance; Pilot; D. After Appliance is Lit; Initial Break-in Procedure; : The appliance should be run three to four hours; • If adjustment is needed remove cap screw from gas valve; • Do NOT turn adjustment screw counter-clockwise too far
Heat & Glo • FB-IN, FB-GRAND • 783-908 Rev. J • 2/07 28 C. Check Pilot Flame Appearance Pilot fl ame must contact the thermocouple and thermopile for reliable appliance operation.• Pilot fl ame should be as shown in Figure 12.1. D. After Appliance is Lit Initial Break-in Procedure When you light...
Page 29 - E. Frequently Asked Questions; ISSUE
Heat & Glo • FB-IN, FB-GRAND • 783-908 Rev. J • 2/07 29 E. Frequently Asked Questions Fire Risk.High Temperatures.Keep combustible household items away from appliance.Do NOT obstruct combustion and ventilation air. • Do NOT place combustible items on top of or in front of appliance. • Keep furni...
Page 30 - A. Standing Pilot Ignition System; Troubleshooting; ed service person in the diagnosis of a problem and the; Symptom
Heat & Glo • FB-IN, FB-GRAND • 783-908 Rev. J • 2/07 30 A. Standing Pilot Ignition System 13 13 Troubleshooting With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service. If you do experience a problem, this troubleshooting guide will assi...
Page 32 - Maintaining and Servicing Appliance; ed; When cleaning glass door:
Heat & Glo • FB-IN, FB-GRAND • 783-908 Rev. J • 2/07 32 14 14 Maintaining and Servicing Appliance Although the frequency of appliance servicing and maintenance will depend on use and the type of installation, a quali fi ed service technician should perform an appliance checkup at the beginning o...
Page 34 - Reference Materials; A. Appliance Dimension Diagram
Heat & Glo • FB-IN, FB-GRAND • 783-908 Rev. J • 2/07 34 Figure 15.1 Appliance Dimensions D F E H G ELECTRICAL ACCESS (IF EQUIPPED) GAS INLET C A B 2-1/16 in. 52 mm 1-9/16 in. 40 mm 3-9/16 in. 91 mm 1-1/16 in. 28 mm 2-1/2 in. 64 mm 4 in. 102 mm 13-3/4 in. 350 mm 3-1/8 in. 80 mm 6-5/8 in.169 mm Tw...
Page 35 - B. Vent Kits Components; ex liner; ashing kit for use
Heat & Glo • FB-IN, FB-GRAND • 783-908 Rev. J • 2/07 35 B. Vent Kits Components Direct Vent Flex Liner Kits (see Figure 15.2)LINK-DV-30B or (LINK-DV-30): Masonry 3 inch fl ex liner kit. Expands to 30 feet. Includes: two liners, termination cap, fl ashing, and link adapter. LINK-DV4-30B or (LINK-...
Page 36 - Service Parts; Service Parts Diagram; Part number list on following page.; Log Set Assembly
Heat & Glo • FB-IN, FB-GRAND • 783-908 Rev. J • 2/07 36 Service Parts Service Parts Diagram FB-GRAND Beginning Manufacturing Date: 8-02 Ending Manufacturing Date: ______ Part number list on following page. 5 6 7 8 9 10 11 12 13 14 15 16 17 17 19 Log Set Assembly 1 2 3 4
Page 40 - D. Limited Lifetime Warranty; vicing by an authorized HEAT & GLO dealer.
Heat & Glo • FB-IN, FB-GRAND • 783-908 Rev. J • 2/07 40 © 2005 Hearth & Home Technologies Inc. LIMITED LIFETIME WARRANTY HEAT & GLO GAS APPLIANCE PRODUCTS 060-981D 3/05 D. Limited Lifetime Warranty BASIC ONE-YEAR WARRANTY. HEAT & GLO, a brand of HEARTH & HOME TECHNOLOGIES INC., l...
Page 41 - E. Contact Information; For the location of your nearest Heat & Glo dealer,; DO NOT DISCARD THIS MANUAL
Heat & Glo • FB-IN, FB-GRAND • 783-908 Rev. J • 2/07 41 Heat & Glo, a brand of Hearth & Home Technologies Inc. 20802 Kensington Boulevard, Lakeville, MN 55044 www.heatnglo.com E. Contact Information Please contact your Heat & Glo dealer with any questions or concerns. For the locatio...