Page 2 - Congratulations; Listing Label Information/Location; Owner’s Manual; Read this manual before installing or operating this appliance.; Homeowner Reference Information; NATURA L GAS; XXXXXXXX
2 Heat & Glo • 8000TV-OAK, 8000TV-OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev. L • 08/08 Congratulations Listing Label Information/Location Model Name: ___________________________________________ Date purchased/installed: __________________ Serial Number: __________________________________________ L...
Page 3 - Table of Contents; A. Maintenance Tasks
3 Heat & Glo • 8000TV-OAK, 8000TV-OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev. L • 08/08 Î = Contains updated information. Table of Contents 1 Listing and Code Approvals A. Appliance Certifi cation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4B. Glass Specifi cations . . . . . . . . . . ...
Page 4 - B. Glass Specifi cations; ANSI; A. Appliance Certifi cation; NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.; C. BTU Specifi cations; , and local Building Offi cials for; D. High Altitude Installations; Listing and Code Approvals; This installation must conform with local codes. In the; Models
4 Heat & Glo • 8000TV-OAK, 8000TV-OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev. L • 08/08 MODELS: 8000TV-OAK, 8000TV-OAK-IPI, 8000TVLP-OAKIPI LABORATORY: Underwriters Laboratories, Inc. (UL) TYPE: B-Vent Decorative STANDARD: ANSI Z21.50-2002 • CGA2.2 B. Glass Specifi cations Hearth & Home Technol...
Page 6 - A. Design and Installation Considerations; Where the appliance is to be installed.; See Sections 3; The vent system confi guration to be used.; See Sections; Framing and fi nishing details.; Getting Started
6 Heat & Glo • 8000TV-OAK, 8000TV-OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev. L • 08/08 A. Design and Installation Considerations Heat & Glo B-type vent gas appliances are designed to operate with all exhaust gases expelled to the outside of the building, and combustion air pulled from the room...
Page 7 - Negative pressure; combustion fumes and soot.; WARNING
7 Heat & Glo • 8000TV-OAK, 8000TV-OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev. L • 08/08 Recommended Location MarginalLocation Location Not Recommended Recommended Location Location NOT Recommended Multi-level Roofs Windward Leeward Figure 2.1 B. Negative Pressure Draft is the pressure difference ne...
Page 8 - Any such action may cause a fi re hazard.
8 Heat & Glo • 8000TV-OAK, 8000TV-OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev. L • 08/08 D. Inspect Appliance and Components C. Tools and Supplies Needed Before beginning the installation be sure that the following tools and building supplies are available. Reciprocating saw Framing material Pliers ...
Page 9 - • Vent Clearances and Framing; Framing and Clearances; A. Selecting Appliance Location
9 Heat & Glo • 8000TV-OAK, 8000TV-OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev. L • 08/08 A B C D E F G Inches 55-7/8 1/2 79 49 Min. 1 37-3/8 22 Millimeters 1419 13 2007 1245 25 949 559 Figure 3.1 Appliance Locations In addition to these framing dimensions, also reference the following sections:• Cle...
Page 10 - CLEARANCES TO COMBUSTIBLES; B. Constructing the Appliance Chase
10 Heat & Glo • 8000TV-OAK, 8000TV-OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev. L • 08/08 CLEARANCES TO COMBUSTIBLES A B C D E F G H I J Rough Opening (Vent Pipe) Rough Opening (Height) Rough Opening (Depth) Rough Opening (Width) Clearance to Ceiling Combustible Floor Combustible Flooring Behind App...
Page 11 - D. Mantel Projections; TOP VIEW
11 Heat & Glo • 8000TV-OAK, 8000TV-OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev. L • 08/08 D. Mantel Projections 1/2 INCH (13 mm) 32 IN. (813 mm) TOP OF HOOD 12 IN. (305 mm) NON-COMBUSTIBLE MATERIAL ONLY 13 IN. (330 mm) CEILING TOP FRONT EDGE OF FIREPLACE Note: Clearance from opening to perpendicular...
Page 12 - * 3 foot minimum in snow regions; A. Vent Termination Minimum Clearances; • Do not pack air space with insulation or other; Termination Locations
12 Heat & Glo • 8000TV-OAK, 8000TV-OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev. L • 08/08 Roof Pitch H (Min.) Ft. Flat to 6/12...........................................................1.0*Over 6/12 to 7/12 .................................................1.25*Over 7/12 to 8/12 ........................
Page 13 - Vent Information and Diagrams; B. Vent System Confi guration; Other vent
13 Heat & Glo • 8000TV-OAK, 8000TV-OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev. L • 08/08 METAL PLUMBER’S STRAP 9 FEET MINIMUM VENT SUPPORTS ARE PER VENT MANUFACTURER’S SPECIFICATIONS MINIMUM CLEARANCES ARE PER VENT MANUFACTURER’S SPECIFICATIONS METAL PLUMBERS' STRAP MAXIMUM HORIZONTAL RUN IS 50% OF...
Page 14 - Maximum
14 Heat & Glo • 8000TV-OAK, 8000TV-OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev. L • 08/08 Fire Risk. Explosion Risk. Insulation and other combustibles must not infringe on clearances. • ALWAYS maintain specifi ed clearances around venting and fi restop systems. • Install fi restops as specifi ed. Fa...
Page 15 - This product MUST terminate vertically.; B. Vertical Penetration Framing; Fire Hazard; A. Pipe Clearances to Combustibles; Vent Clearances and Framing
15 Heat & Glo • 8000TV-OAK, 8000TV-OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev. L • 08/08 Note: This product MUST terminate vertically. Follow vent pipe manufacturer’s instructions for all clear-ances around pipe. B. Vertical Penetration Framing Use B-vent manufacturer’s fi restops to provide adequa...
Page 16 - Do NOT draw outside combustion air from:; B. Gas and Electrical Connections; Appliance Preparation; glasses during installation.; C. Securing and Leveling Appliance
16 Heat & Glo • 8000TV-OAK, 8000TV-OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev. L • 08/08 A. Installing Outside Air Kit Damper Assembly Asphyxiation Risk. Fire Risk. Do NOT draw outside combustion air from: • Wall, fl oor or ceiling cavity. • Enclosed space such as an attic or garage. • Close proxim...
Page 17 - • Do NOT notch into the framing around the appliance spacers.; E. Checking Pilot Plate; Straighten the tabs on the grate bracket (see Figure; Ensure pilot plate is in place. This will ensure pilot
17 Heat & Glo • 8000TV-OAK, 8000TV-OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev. L • 08/08 Figure 7.3 Proper Positioning, Leveling and Securing of a Appliance NAILING TABS (BOTH SIDES) Fire Risk. • ALWAYS maintain specifi ed clearances around the appliance. • Do NOT notch into the framing around the ...
Page 18 - A. Assembly of Vent Sections; Fire Risk; B. Attaching Vent to Firebox; Combustion Fume Risk.; C. Securing Vent Sections; SECURING; Installing Vent Pipe
18 Heat & Glo • 8000TV-OAK, 8000TV-OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev. L • 08/08 A. Assembly of Vent Sections This appliance requires a 6-inch B-vent double-wall pipe. Follow the pipe manufacturer’s installation guidelines when installing the unit. This will ensure proper operation and prev...
Page 19 - Have the gas supply line installed in accordance; Gas Information; • If substituting for these components, please consult; Refer to; Reference Section 16; for location of gas line; The gap between supply piping and gas access hole; Pressure; Minimum inlet pressure
19 Heat & Glo • 8000TV-OAK, 8000TV-OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev. L • 08/08 Note: Have the gas supply line installed in accordance w i t h l o c a l b u i l d i n g c o d e s , i f a ny. I f n ot , f o l l o w A N S I 223.1. Installation should be done by a qualifi ed installer approve...
Page 20 - HIGH ALTITUDE INSTALLATIONS; • Ensure that gas line does not come in contact with outer
20 Heat & Glo • 8000TV-OAK, 8000TV-OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev. L • 08/08 Fire hazard. Do NOT change the valve settings. • This valve has been preset at the factory. • Changing valve settings may result in fi re hazard or bodily injury. HIGH ALTITUDE INSTALLATIONS U.L. Listed gas app...
Page 21 - A. Recommendation for Wire; Electrical Information; National Electric Code ANSI/NFPA 70-latest; B. Connecting to the Appliance; Wire 110V to electrical junction box.; Wall Switch
21 Heat & Glo • 8000TV-OAK, 8000TV-OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev. L • 08/08 • This appliance MUST be used with a wall switch or a remote control. • This unit is not for use with thermostats. • Keep wire lengths short as possible by removing any excess wire length. • Low voltage and 110...
Page 22 - C. Intellifi re Ignition System Wiring; Batteries cannot be placed in the battery pack; Optional Accessories Requirements; CAUTION; • Replace damaged wire with type 105o C rated
22 Heat & Glo • 8000TV-OAK, 8000TV-OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev. L • 08/08 C. Intellifi re Ignition System Wiring This appliance requires a 110 VAC supply to the appliance junction box for operation. A wiring diagram is shown in Figure 10.2. This appliance is equipped with an Intellif...
Page 23 - D. Standing Pilot Ignition System Wiring
23 Heat & Glo • 8000TV-OAK, 8000TV-OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev. L • 08/08 D. Standing Pilot Ignition System Wiring This standing pilot ignition system wiring does not require a 110 VAC supply to operate. Figure 10.3 Standing Pilot Ignition Wiring Diagram Figure 10.2 Intellifi re Pilo...
Page 24 - If the box is being wired from the appliance:; E. Junction Box Installation; Do NOT wire
24 Heat & Glo • 8000TV-OAK, 8000TV-OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev. L • 08/08 If the box is being wired from the appliance: • Remove the screw attaching the junction box to the outer shell, rotate the junction box inward to disengage it from the outer shell (see Figure 10.4). • P u l l t...
Page 25 - A. Mantel Projections; Finishing
25 Heat & Glo • 8000TV-OAK, 8000TV-OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev. L • 08/08 Fire Risk Explosion Risk • Facing and/or finishing materials must never overhang into the glass opening. • Overhanging materials may ignite. • May interfere with proper operation of glass assembly. Figure 11.3 ...
Page 26 - A. Remove Shipping Materials; EMBER; DO NOT; Appliance Setup
26 Heat & Glo • 8000TV-OAK, 8000TV-OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev. L • 08/08 Ember material is shipped with this gas appliance. To place the ember material: • When placing Glowing Embers ® onto the burner care should be taken so that the ports are not covered. Place the dime-size ember ...
Page 27 - F. Positioning the Logs; Carefully remove the logs from the packaging.; LOG TAB
27 Heat & Glo • 8000TV-OAK, 8000TV-OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev. L • 08/08 Log Assembly: LOGS-8OAK F. Positioning the Logs If the gas logs have been factory installed they should not need to be positioned. If the logs have been packaged separately, refer to the following instructions....
Page 29 - Removing Glass Assembly; Shutter Settings; Fixed
29 Heat & Glo • 8000TV-OAK, 8000TV-OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev. L • 08/08 H. Screen Mesh The screen mesh is a protective barrier and must be at-tached. I. Grilles and Trim Install optional marble and brass trim surround kits as de-sired. Marble, brass, brick, tile, or other non-combu...
Page 30 - B. Check Appliance Draft; If installing Intellifi re ignition battery backup:; HOT SURFACES
30 Heat & Glo • 8000TV-OAK, 8000TV-OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev. L • 08/08 Before operating this appliance have a qualified technician: • Remove all shipping materials from inside and/or underneath the fi rebox. • Review proper placement of logs, rockwool, lava rock, and vermiculite. ...
Page 31 - C. Lighting Appliance; NOT FOR USE; GAS; WHAT TO DO IF YOU SMELL GAS; Final inspection by
31 Heat & Glo • 8000TV-OAK, 8000TV-OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev. L • 08/08 C. Lighting Appliance 1. Turn off all electric power to the appliance. 2. This appliance is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand. 3. Wai...
Page 32 - Standing Pilot Ignition
32 Heat & Glo • 8000TV-OAK, 8000TV-OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev. L • 08/08 Standing Pilot Ignition 1. Turn off all electric power to the appliance if service is to be performed. 2. Open control access panel. 3. Move switch to “OFF” position. 4. Push in gas control knob slightly and tu...
Page 33 - Initial Break-in Procedure; The appliance should be run three to four hours; D. After Appliance is Lit; ISSUE
33 Heat & Glo • 8000TV-OAK, 8000TV-OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev. L • 08/08 Initial Break-in Procedure When you light the appliance, you may notice that it pro-duces heat which does have an associated odor or smell. If you feel this odor is excessive it may require the initial three to...
Page 34 - A. Standing Pilot Ignition System; Troubleshooting; Symptom
34 Heat & Glo • 8000TV-OAK, 8000TV-OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev. L • 08/08 A. Standing Pilot Ignition System 14 14 Troubleshooting With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service. If you do experience a problem, this t...
Page 35 - Replace glass panel assembly.
35 Heat & Glo • 8000TV-OAK, 8000TV-OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev. L • 08/08 Troubleshooting (continued) Symptom Possible Cause Corrective Action 3. Continued c. Defective valve. Turn the valve knob to the ON position. Place the ON/OFF switch in the ON position. Check the millivolt mete...
Page 36 - B. Intellifi re Ignition System; Sympton; Verify that 110/VAC power is “ON” to junction box.
36 Heat & Glo • 8000TV-OAK, 8000TV-OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev. L • 08/08 B. Intellifi re Ignition System Sympton Possible Cause Corrective Action 1. The ignitor/module makes noise, but no spark. a. Incorrect wiring. Verify “S” wire (white) for sensor and “I” wire (orange) for ignito...
Page 38 - Maintaining and Servicing Appliance; Clean glass after initial 3-4 hours operation.; When cleaning glass door:
38 Heat & Glo • 8000TV-OAK, 8000TV-OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev. L • 08/08 15 15 Maintaining and Servicing Appliance Although the frequency of appliance servicing and maintenance will depend on use and the type of installation, a qualifi ed service technician should perform an applian...
Page 40 - Reference Materials; A. Appliance Dimension Diagram; Location Inches
40 Heat & Glo • 8000TV-OAK, 8000TV-OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev. L • 08/08 16 16 Reference Materials ELECTRICALACCESS A B C D E F G I GAS LINEACCESS J K L M O P Q R H N A. Appliance Dimension Diagram Dimensions are actual appliance dimensions. Use for reference only. For framing dimen...
Page 41 - Service Parts; Service Parts Diagram; Log Set Assembly; Part number list on following page.
41 Heat & Glo • 8000TV-OAK, 8000TV-OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev. L • 08/08 Service Parts Service Parts Diagram 8000TV-OAK, 8000TV-OAK-IPI Beginning Manufacturing Date: Feb. 2005 Ending Manufacturing Date: ______ 8 9 10 11 12 13 7 Log Set Assembly Part number list on following page. 6 ...
Page 42 - Addional service part numbers appear on following page; B. Service Parts List
42 Heat & Glo • 8000TV-OAK, 8000TV-OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev. L • 08/08 IMPORTANT: THIS IS DATED INFORMATION, When requesting service or replacement parts for your appliance please provide model number and serial number. All parts listed in this manual may be ordered from an author...
Page 43 - Valve Assembly Parts List; IPI Valve Assembly; Stocked; ITEM
43 Heat & Glo • 8000TV-OAK, 8000TV-OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev. L • 08/08 Service Parts Valve Assembly Parts List 8000TV-OAK-IPI Beginning Manufacturing Date: Feb. 2005 Ending Manufacturing Date: ______ 6 7 8 1 5 9 3 2 4 IPI Valve Assembly IMPORTANT: THIS IS DATED INFORMATION, When r...
Page 44 - Standing Pilot Valve Assembly
44 Heat & Glo • 8000TV-OAK, 8000TV-OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev. L • 08/08 Service Parts Valve Assembly Parts List 8000TV-OAK Beginning Manufacturing Date: Feb. 2005 Ending Manufacturing Date: ______ Standing Pilot Valve Assembly 1 2 3 4 5 6 7 8 9 IMPORTANT: THIS IS DATED INFORMATION,...
Page 45 - C. Limited Lifetime Warranty; unless expressly authorized and approved by HEAT & GLO in writing.
45 Heat & Glo • 8000TV-OAK, 8000TV-OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev. L • 08/08 © 2007 Hearth & Home Technologies Inc. LIMITED LIFETIME WARRANTY HEAT & GLO GAS APPLIANCE PRODUCTS 060-981E 10/07 C. Limited Lifetime Warranty BASIC ONE-YEAR WARRANTY. HEAT & GLO, a brand of HEARTH ...
Page 46 - D. Contact Information; For the location of your nearest Heat & Glo dealer,; DO NOT DISCARD THIS MANUAL; • Leave this manual with
46 Heat & Glo • 8000TV-OAK, 8000TV-OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev. L • 08/08 Heat & Glo, a brand of Hearth & Home Technologies Inc. 20802 Kensington Boulevard, Lakeville, MN 55044 www.heatnglo.com D. Contact Information Please contact your Heat & Glo dealer with any question...