Page 2 - with; ComfortReadTM Technology; IMPORTANT SAFETY INSTRUCTIONS; DO NOT DESTROY; In accordance with International Standards:; INSTRUCCIONES DE MEDIDAS IMPORTANTES; Medidor de Presión; con; T ecnología; NO DESTRUY; De Conformidad con Estándares Internacionales:
2 2 Upper Arm Blood Pressure Monitor with ComfortRead™ Technology IMPORTANT SAFETY INSTRUCTIONS DO NOT DESTROY Features: • Fully-Automatic • One-Touch Operation • Extra Large, Easy-To-Read Digital Display • 90 Automatic Memory Feature • ComfortRead ™ Technology Minimizes Cuff Pressure, Maximizes Com...
Page 3 - Table of Contents; Introduction; Indice; Indroducción
3 Table of Contents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4 Product Component Identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Comfort Read™ Measuring Technology . . . . . . . . . . . . . . . . ....
Page 4 - Product Component Identification:; LCD Display; Identificación de los Componentes del Producto
4 6 4 Blood pressure measurements determined with the Health o meter ® blood pressure monitor are equivalent to those using the cuff/stethoscope auscultation methodand are within the limits prescribed by the American National Standards Institute(ANSI). This monitor is to be used by an adult and is i...
Page 5 - Standards of Quality; BOUT; What is Blood Pressure?; CERCA; ¿Qué es la Presión Arterial?
5 Standards of Quality This Blood Pressure Monitor conforms with the American National StandardsInstitute/American Association of Medical Instrumentation Standards for Non-InvasiveBlood Pressure Monitors. In addition, the device complies with the Europeanregulations and bears the CE mark “CE 0366”. ...
Page 6 - Hypertension; Estándar de Presión Arterial; Hipertensió
6 6 Blood Pressure Standard The World Health Organization (WHO) has developed a blood pressurestandard, according to which areas of low and high-risk blood pressureare identified. This standard, however, is a general guideline as individualblood pressure varies among different people and different a...
Page 7 - Display Explanations; Systolic Pressure; Installing Batteries; Presión Sistólica; Instalación de las Baterías
7 7 Display Explanations Display: Systolic Pressure Diastolic Pressure Pulse Rate No. of Memory Sequence Icons: Appears when measurement value is storedin memory or is recalled from memory Appears when batteries should be replaced Shows the Pulse Rate per minute Occurs when an error was made duringm...
Page 9 - Applying the Arm Cuff; Position the artery mark [ ] over the; Colocación del Brazalete en el Brazo
9 9 Applying the Arm Cuff 1. Plug the cuff connector tube (A) into the unit. 2. Unwrap the arm cuff, leaving the “Index” end of the cuff throughthe metal D-ring (B) of the cuff. 3. Put your left arm through the cuff loop. The “OK” range indication shouldbe positioned at the top with the rubber tube ...
Page 10 - Taking a Measurement; T omando una Medición
18 1 0 10 5. If the Index line falls within the OK range, indicated at the edge of thecuff, this cuff is suitable for your use. If the Index line falls outside of the OK range, you may need a larger cuff for accurate measurement.Please consult your local retailer for the purchase of a larger cuffor ...
Page 11 - 0 measurement readings will be saved into memory.; Recalling Memory; MEMORY
1 1 11 3. When cuff pressure reaches your approximate systolic blood pressure,measurement will be complete and will be followed by the release ofcuff pressure. When the monitor completes the measurement, it will automaticallydisplay and store the systolic, diastolic and pulse reading into memory.The...
Page 12 - Troubleshooting; Solución de Problemas
22 1 2 12 Note: 1. The data in the memory will not be lost even when the Blood PressureMonitor is switched off. 2. You can erase the memories stored by removing the batteries. Troubleshooting If a problem should arise during use, please check the following points. Note: If the unit still does not wo...
Page 15 - Y our Measur; BloodPressure; ComfortReadTMT
IMPORT ANT NOTES Y our Measur e for Good Health™ UP PE R A RM BloodPressure Monitor with ComfortRead™T echnology
Page 16 - ComfortReadTM T echnology; DO NOT DESTR; 0 Automatic Memory Feature; Tecnología ComfortReadTM; NO DESTRUYA
2 2 Upper Arm Blood Pressure Monitor with ComfortRead™ T echnology IMPORTANT SAFETY INSTRUCTIONS DO NOT DESTR OY Features: • Fully-Automatic • One-T ouch Operation • Extra Large, Easy-T o-Read Digital Display • 90 Automatic Memory Feature • ComfortRead ™ T echnology Minimizes CuffPressure, Maximizes...
Page 17 - T able of Contents
3 T able of Contents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4 Product Component Identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Comfort Read™ Measuring T echnology . . . . . . . . . . . . . . . ....
Page 19 - Estándares de Calidad; CERCA DE LA
5 Standards of Quality This Blood Pressure Monitor conforms with the American National Standards Institute/American Association of Medical Instrumentation Standards for Non-Invasive Blood Pressure Monitors. In addition, the device complies with theEuropean regulations and bears the CE mark “CE 0366”...
Page 20 - Hipertensión
6 6 Blood Pressure Standard The World Health Organization (WHO) has developed a blood pressure standard, according to which areas of low and high-risk blood pressure areidentified. This standard, however , is a general guideline as individual blood pressure varies among different people and differen...
Page 21 - Descripciónes de la Pantalla
7 7 Display Explanations Display: Systolic Pressure Diastolic Pressure Pulse Rate No. of Memory Sequence Icons: Appears when measurement value is stored inmemory or is recalled from memory Appears when batteries should be replaced Shows the Pulse Rate per minute Occurs when an error was made during ...
Page 22 - Wait about 5 minutes before taking a SECOND blood pressure; Usted debe cambiar baterías cuando:; Consejos Utiles
1 4 8 8 Y ou need to replace the batteries when: 1. The “low battery” icon appears on the display. 2. The “POWER” button is pushed and nothing appears on the display Note: Discard used Alkaline batteries as directed by your local environmental codes. HOW TO USE: Helpful T ips Here are a few tips to ...
Page 23 - Position the artery mark [ ] over the
9 9 Applying the Arm Cuff 1. Plug the cuff connector tube (A) into the unit. 2. Unwrap the arm cuff, leaving the “Index” end of the cuff through themetal D-ring (B) of the cuff. 3. Put your left arm through the cuff loop. The “OK” range indication should be positioned at the top with the rubber tube...
Page 24 - cuff, this cuff is suitable for your use.; T aking a Measurement; Tomando una Medición
1 8 10 1 0 5. If the Index line falls within the OK range, indicated at the edge of the cuff, this cuff is suitable for your use. If the Index line falls outside of theOK range, you may need a larger cuff for accurate measurement. Pleaseconsult your local retailer for the purchase of a larger cuff o...
Page 26 - T roubleshooting
2 2 12 1 2 Note: 1. The data in the memory will not be lost even when the Blood Pressure Monitor is switched off. 2. Y ou can erase the memories stored by removing the batteries. T roubleshooting If a problem should arise during use, please check the following points. Note: If the unit still does no...