Page 2 - Exception TL200 W ood Stove; Table of Contents; The H arman TL2 00 meets the U.S. Environmental
Exception TL200 W ood Stove 2 Specifications 3 Operation 5 Building a Fire 7 Maintenance 9 Installation 11 Door Installation Tips 13 Linkage Installation 14 Chimney System 17 Parts List 21 Parts Diagram 22 Warranty 23 Table of Contents Introduction The H arman TL2 00 meets the U.S. Environmental Pro...
Page 3 - Specifications
Exception TL200 W ood Stove 3 Specifications W eight 440 lbs Flue Size 6 inch Log Length Recommended 18" with 20" Max Heating Capacity 1500 to 2800 sq. ft. Average Emissions 4.4 Grams Per Hr. Emissions on Low 2.25 Grams Per Hr. Blower Size (optional) 105 cfm variable speed Outside Air size 3...
Page 5 - Grates; Operation; General Considerations; WARNINGS; The Stove
Exception TL200 W ood Stove 5 All doors must be closed while the stove is in normal operation, and the gaskets routinely examined for wearand replaced when necessary. The fuel door may be leftopen and the opening covered with a screen when operat-ing as a fireplace. Good door seals are important for...
Page 6 - The Combustion Process; Controls
Exception TL200 W ood Stove 6 The Combustion Process Combustion in your Harman Exception is controlled very precisely. During a wood fire, primary combustion airenters the bottom of the stove, is directed up to the top ofthe load door and then down past the glass, finally enter-ing the combustion ch...
Page 7 - Air Control; More; Building and Maintaining the Fire; Reloading
Exception TL200 W ood Stove 7 Air Control The air control lever is located directly below the ash lip of the stove. Using this lever you will be able to vary theamount of air delivered to the fire, creating a range of heatoutputs. The low heat output setting is to the left, andhigh is to the far rig...
Page 8 - Operating as a Fireplace; Afterburner Viewport; Overfiring
Exception TL200 W ood Stove 8 Operating as a Fireplace The TL200 is tested and approved to be burned with the front load door open and the damper open. In this modeof operation you get a true fire sound as well as appear-ance. Due to the crackling and popping of burning wood itis necessary to place ...
Page 9 - Maintenance; The Fire Chamber; The Door
Exception TL200 W ood Stove 9 Maintenance The Fire Chamber The inside of the fire chamber should be exam- ined for damage to the refractory lining material, grates,casting or Afterburner glass. If any bricks have been dam-aged, replace them with Harman Stove Company replace-ment parts. Glass - Repla...
Page 10 - The Chimney System
Exception TL200 W ood Stove 10 The Chimney System Creosote W hen wood is burned slowly, it produces tar and other organic vapors, as well as soot, which combine withexpelled moisture to form creosote . The creosote vaporscondense in the relatively cool chimney flue (associatedwith a slow burning fir...
Page 11 - DO NOT INSTALL IN A SLEEPING ROOM; Installation; Assembly
Exception TL200 W ood Stove 11 DO NOT INSTALL IN A SLEEPING ROOM Blower VariableSpeed knob 3" Outside Air Installation Assembly Blower (optional) Bolt the mounting plate to the bottom rear of the stove with four 1/4-20 bolts. Put the blower in place on thebracket and bolt fast. Tighten the bolts...
Page 12 - Floor Protection; Clearances
Exception TL200 W ood Stove 12 Installation Floor Protection In all installations, the area under and around the stove must be protected from falling ash and live coals. The area under a horizontal run of chimney connector mustalso be protected . This protector must be of noncombus- tible material, ...
Page 13 - Door Assembly/Installation Tips; Door Glass
Exception TL200 W ood Stove 13 Door Assembly/Installation Tips Door Glass • Be sure that the door glass is installed in the door with the label, located on the glass, on the external side of thedoor. • Rope the glass carefully to insure proper sealing. • Apply the rope exactly along the edge of the ...
Page 14 - Exception Linkage Installation; Figure 1
Exception TL200 W ood Stove 14 Exception Linkage Installation Figure 1 Step 1: Remove left side shield The side shield has tabs on it that latch into holes on the side of the stove. This makes removing the side shield easy. • Lift up on the side shield then pull out. Drive Arm Assembly Heavy Washer ...
Page 15 - Exception Linkage Installation, cont'd; Things to Check; Step 3: Install the top lift arm
Exception TL200 W ood Stove 15 Figure 5 Figure 6 Self-Locking Nut Shoulder Pin Before tighteningthe nut be surethe bolt is tightin the lid. Exception Linkage Installation, cont'd Self-Locking Nut Step 2: Install the top lift/drive arm Step 4: Re-attach left side shield. • Place side shield under top...
Page 17 - Venting; Chimney Connectors and Chimneys; Chimney Connectors
Exception TL200 W ood Stove 17 The Ha rman Exce pt ion may be i ns ta lle d wi th a minimum o f (1 50 mm) 24 gauge c himne y co nnec to rpipe. Si ze o f the co nnec to r s ho uld co rr es po nd t o thes ize of t he f lue c olla r opening. Do not use makeshiftcompromises. No part of the chimney conne...
Page 18 - The Chimney
Exception TL200 W ood Stove 18 The Chimney The Exception must be installed into a chimney approved for use with solid-fuel appliances. In the U.S.,the Exception must be connected to (1) a prefabricatedchimney complying with the requirements for Type HT chim-neys in the Standard for Chimneys, Factory...
Page 19 - Existing Masonry Chimneys; Venting to a Masonry Chimney
Exception TL200 W ood Stove 19 Existing Masonry Chimneys If you plan on using a pre-existing masonry chim- ney, have it thoroughly inspected and cleaned. Any faultswhich make the chimney unsafe and unusable must berepaired prior to use. These can include improper height,structural defects, blockages...
Page 20 - Moblie Home Installations; Venting - Mobile Homes
Exception TL200 W ood Stove 20 Moblie Home Installations Mobile home installations must use approved fac- tory-built chimneys tested and listed for this specific use,to either of the high temperature standards, ULC S-629 orUL 103. Any components used to install the chimneymust be listed for this use...
Page 21 - Exception Parts List
Exception TL200 W ood Stove 21 Exception Parts List 1. 1-10-08074 Damper linkage we ldment 2. 1-10-08075 Damper pivot arm weldment 3. 1-10-08127 Top lift arm weldment 4. 2-00-05204 Left side shield 5. 3-40-05228 W ooden knob 6. 3-40-05171 Ceramic fiber afterburner 7. 1-10-08058 Left side plate assy....
Page 23 - Harman Gold Warranty
Exception TL200 W ood Stove 23 Harman Stove Company warrants its products to be free from defects in material or workmanship, in normal use and service, for a period of 6 years from the date of sales invoice and for mechanical and electrical failures, innormal use and service, for a period of 3 year...