  • Page 2 – Introduction; 52 Mountain House Road; Table of Contents
  • Page 3 – Automatic Ignition/Operation; Stove Temperature M ode
  • Page 4 – Starting First Fire; Automatic Start Up
  • Page 5 – NOTE: During the use of this mode, if you keep; Manual Ignition/Operation; Manual Stove Temperature M ode
  • Page 6 – Manual Start Up; to “OFF” and; Warning
  • Page 7 – ESP Control; Status light error messages:; Indicates control board self diagnostic fail-; Blinks; : Indicates that the control has calculated
  • Page 8 – CAUTION; The stove is hot while in operation.; Installation; AFTER THE INSTALLATION IS COMPLETED
  • Page 9 – The Accentra unit is shipped; Adjustment of the rubber pad leveling feet; The rear two studs are to the right and left of
  • Page 10 – AFTER THE INSTALLATION IS COMPLETED; THE STRUCTURAL INTEGRITY OF THE; Mobile Home Installation
  • Page 11 – required; Draft Meter bolt hole location; Low Draft Voltage Adjustment
  • Page 12 – It is recommended that the room sensor be; even if only installed on the rear of the; Room Sensor Installation; Room Sensor and Rear Shield Installation; Rear Shields; NOTE: It is not recommended that the; REMINDERS
  • Page 13 – Be sure to us e approv ed; Venting; Vent Pipe; w e spe ci fy th at th e j oi n ts a l so be; Outside Air; IMPORTANT NOTICE; Pellet Vent Pipe or PL Vent Pipe Must be used.
  • Page 14 – #1 Pref erred method; This method provides excellent venting for nor-; Note: Do not place joints w ithin; KEEP COMBUSTIBLES (SUCH AS; #2 Preferred method; This method also provides excellent venting for; Note: Do not place joints w ithin w all pass-
  • Page 15 – #4 Installing into an existing
  • Page 16 – #6 Installing into an existing fireplace
  • Page 17 – Minimum flue vent configuration; It is r e c o mme n de d th a t; #8 Installing through the ceiling vent; Thr o ugh t he c e iling ve nt, f o llo w PL v e nt
  • Page 18 – Requirements for Terminating the Venting; any other appliance must be a minimum of 48”.; w ith outside air installed, 6 feet; exterior combustibles such as mulch is 36” as mea-
  • Page 19 – Maintenance - Cleaning Glass on View Door; rags such as cotton or paper towels.
  • Page 20 – Maintenance - Cleaning; Heat Exchanger channel cover latch; Cleaning Internal Components; To remove the feeder cover:; Slide the cover off of the threaded stud.
  • Page 22 – Burn Pot Cleaning and Maintenance; The ignito r is made to be removable f or; DANGE R; m ust always be pulled to the rear of the; Maintenance - Burn Pot
  • Page 23 – ll
  • Page 25 – Specifications
  • Page 26 – Accentra Wiring Diagram
  • Page 27 – Accentra Feeder Parts
  • Page 28 – Accentra Parts List
  • Page 29 – Harman Gold Warranty
Loading the manual

SAFETY NOTICE

PLEASE READ THIS ENTIRE MANUAL BEFORE YOU INSTALL AND USE YOUR NEW ROOM HEATER. FAILURE TO
FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY, OR EVEN DEATH.

FOR USE IN THE U.S. AND CANADA. SUITABLE FOR INSTALLATION IN MOBILE HOMES

IF THIS HARMAN ACCE NT RA P EL L ET S TOVE IS NOT PROP ERLY INSTALLED, A HOUSEFIRE MAY RESULT. FOR
YOUR SAFETY, FOLLOW INSTALLATION DIRECTIONS.

CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONSAND INSTALLATION INSPECTION
REQUIREMENTS IN YOUR AREA.

CONTACT YOUR LOCAL AUTHORITY (SUCH AS MUNICIPAL BUILDING DEPARTMENT, FIRE DEPARTMENT, FIRE
PREVENTION BUREAU, ETC.) TO DETERMINE THE NEED FOR A PERMIT.

CETTE GUIDE D'UTILISATION EST DISPONIBLE EN FRANCAIS. CHEZ VOTRE CONCESSIONNAIRE DE HARMAN STOVE
COMPANY.

SAVE THESE INSTRUCTIONS.

The Harman Accentra-2 Pellet Stove

Installation & Operating Manual

R4

“Ce manuel est disponible en Français sur demande”

Evaluation notes were added to the output document. To get rid of these notes, please order your copy of ePrint IV now.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Introduction; 52 Mountain House Road; Table of Contents

2 Introduction Harman Stove Company 352 Mountain House Road Halifax, PA 17032 sales@harm anstoves.com sales@harm anstoves.com Table of Contents Automatic Operation 4 Manual Operation 6 ESP Control 8 Assembly & Installation 9 Venting 14 Maintenance 20 Trouble-Shooting 25 Specifications 26 Wiring ...

Page 3 - Automatic Ignition/Operation; Stove Temperature M ode

3 The Accentra pellet stove is more than just automatic ignition, it is also automatic temperaturecontrol. The automatic system will allow the fire size to be adjusted to match the heatingneeds and even put the fire out if necessary. If heat is needed after the fire is out, theAccentra will automati...

Page 4 - Starting First Fire; Automatic Start Up

4 Starting First Fire Ignitor Switch to"AUTO" (down position) Make sure the unit is plugged into a 120 VAC,60 HZ electrical source. The power light shouldbe the only light lit. 1. Turn Mode Selector to "OFF". 2. Fill hopper with pellets. 1 3. Clean burn pot with scraper, if necessary...