Page 3 - Table of Contents
3 Table of Contents Introduction 4 Safety Precautions 4 Operation 5 Specifications 7 Clearances 8 Ins tallation 9 Venting 10 Changing To Natural Gas 14 Option Ins tallation Therm os tat 18 Remote Control 18 Glas s Grill 18 Blower 19 Maintainence 20 Wiring Diagram 22 Parts 24 Trouble Shooting 26 Manu...
Page 4 - Introduction
4 Introduction The Harman Conquest Direct Vent Gas Stove is a listed gas-fired direct vent room fireplace tested byIntertek Testing Services/Warnock Hersey to ANSI Z21.88-2002, C SA 2.33-M02 and C ANL/C GA-2.17-M91. The installation o f the Co nquest Direct Vent Gas Stove must conform with local cod...
Page 5 - HOW TO LIGHT THE FIRE; •If the knob does not pop up when re-
5 OPERATION Operation HOW TO LIGHT THE FIRE 1. STOP! Read the safety information on the front cover of this manual. 2. If using the optional thermostat, set thermostat to the lowest setting. 3. Turn off electric power to the optional blower.4. Turn the ON-OFF switch to the OFF position.5. Push in th...
Page 6 - OPERATION; HOW TO TURN OFF THE FIRE; NOTE: The knob cannot be turned from “PILOT”; FLAME HEIGHT ADJUSTMENT
6 OPERATION 15. Set the High-Low Regulator to desired setting: Turn fully counterclockwise for High and fullyclockwise for Low. NOTE: An odor, resulting from the initial heating of new materials in your heater, is not unusualduring the first fire, and in most cases willdisappear after an hour or two...
Page 7 - SPECIFICATIONS
7 SPECIFICATIONS RATINGS NATURAL PROPANE Input Rating (Btu/hr)(0-4500 ft.)(0-1375 m) 29000 29000 Min. Input Rating (Btu/hr)(0-4500 ft.)(0-1375 m) 14900 14100 Orifices (DMS)(0-4500 ft.)(0-1375 m) 37 53 Manifold Pressure (in w.c./kPa) 3.8/.95 11.0/2.75 Min. Manifold Pressure (in w.c./kPa) 1.1/.27 2.8/...
Page 8 - MINIMUM CLEARANCES FROM COMBUSTIBLE CONSTRUCTION; Unit to corner walls; Alcove Clearances
8 SPECIFICATIONS MINIMUM CLEARANCES FROM COMBUSTIBLE CONSTRUCTION Unit to corner walls 2 in. Unit to side wall 8 in. Unit to back wall 3 in. Unit to alcove ceiling 16 in. Maximum alcove depth 16 in. Electrical Rating: 120 Volts, 60 Hz, > .7 AMP 8” 3” 2” 2” 16” 8” 8” 16” Alcove Clearances Side And...
Page 9 - INSTALLATION; Making The Connection
9 INSTALLATION Only For Qualified Installers Burn Only the Fuel for which the Heater isEquipped The Conquest can burn either natural gas or pro- pane, but requires a change-over kit for natural gas.The label on the burner system module indicates thefuel for which it is equipped. A second label, (on ...
Page 10 - Des cription
10 INSTALLATION Only For Qualified Installers 6-5/8 x 4 8” x 5” Des cription n/a 1208 6” Pipe Length 908B 1208B 6” Pipe Length, Black n/a 1207 9” Pipe Length 907B 1207B 9” Pipe Length, Black 906 1206 12” Pipe Length 906B 1206B 12” Pipe Length, Black 904 1204 24” Pipe Length 904B 1204B 24” Pipe Lengt...
Page 11 - CONQUEST; Rear Vent
11 INSTALLATION Only For Qualified Installers Maximum of four 45 0 elbows allowed. Subtract three feet of total horizontal pipelength for each of the 3rd and 4th 45 0 elbows used. Maximum of two 90 0 elbows allowed. Subtract five feet of total horizontal pipelength for second elbow. Venting with 6 5...
Page 12 - Requirements for Terminating the Venting
12 INSTALLATION Only For Qualified Installers Requirements for Terminating the Venting WARNING: Venting terminals must not be re- cessed into a wall or siding. In addition, the following mus t be obs erved: A. The clearance above grade, or a veran da, porch, deck or balcony must be a minimum of 12...
Page 13 - Natural Gas or Propane; A vent damper is provided to allow fine tuning; Damper Settings; Top Vent Only
13 INSTALLATION Only For Qualified Installers Natural Gas or Propane 0 Feet (rear Vent) Open 6 feet 1/4 to Open 12 feet 1/4 to Open 24 feet Clos ed to 1/2 36 feet Clos ed to 1/2 Range Of Approved Damper Settings A vent damper is provided to allow fine tuning of the draft. Too little draft will cause...
Page 14 - Changing to Natural Gas; Natural Gas Kit; Natural Gas Convers ion Kit
14 INSTALLATION Only For Qualified Installers Changing to Natural Gas Remove pilot tower with a 7/16” wrench. Replace LP orifice with NaturalGas orifice. Seeinstructions in kit. Use a 1/2” deep well socket to remove the LP#53 orifice and replacewith the #37 Natural gasorifice from the kit. Natural G...
Page 16 - Log Placement; The front log s hould be s lide rearward in; Ember Placement; After the logs are positioned, place the embers
16 INSTALLATION Only For Qualified Installers Rear Log Front Log Place the rear log behind the front log with the branchresting on the front log on the right side as shown. Place the front log as shown between the andirons and theair deflector. Log Placement Andiro ns Air Deflector Before lighting a...
Page 17 - Tile Kit; Each tile kit contains six tiles and fifteen allen-; Ins talling Tiles; Below each tile op en in g are three threaded
17 INSTALLATION Only For Qualified Installers Tile Kit Each tile kit contains six tiles and fifteen allen- set screws. If the Conquest is installed as a top vent,then the round tile is not used. If it is installed as arear vent, then the trim ring is not used. Ins talling Tiles Below each tile op en...
Page 18 - Connecting the Optional Thermos tat; Maximum; Remote Control Kit; Note: The ON/OFF switch must be “OFF”; Glas s Grill
18 INSTALLATION (Options) Only For Qualified Installers Connecting the Optional Thermos tat If the optional thermostat is used, it must be plugged into the TH terminals located on thevalve. When installing a millivolt control system, use only a special low resistance thermostat. DO NOTUSE A REGULAR ...
Page 19 - Optional Blower; Ins tallation; “OFF” turn the knob counterclockwise until it clicks.
19 INSTALLATION (Options) Only For Qualified Installers Optional Blower The Blower Kit (Part # 1-00-09102) includes a blower assembly ready to bolt to the left side of thestove and a blower chamber cover. The blower has a variable speed control knob to adjust the blower speed as desired. A special s...
Page 20 - MAINTENANCE; CAUTIONNER: N’opère l’appareil avec le
20 MAINTENANCE Removing the Glas s Front Remove the air grill by pulling forward.Lift the latch shown above and tilt the glass door out at the top and lift off the hooks at the bottom.Handle the glass with care. Replacing the Gas ket The Conquest uses part no. 3-44-00539 fiber- glass gasket in the f...
Page 21 - Cleaning the Burners; Ins pecting the Venting
21 MAINTENANCE Air In Air Out The flow of combus tion and ventilation airmus t not be obs tructed. Cleaning the Burners To clean the burners, you must remove the glass door, logs, and burner screen. With these parts removed, inspect all the holes to make sure they are unobstructed. Use a small drill...
Page 25 - Aluminum ‘J’ tube
25 MAINTENANCE Burner Parts 1 3 2 4 6 5 7 8 9 10 11 14 15 16 13 12 17 1) 3-40-08715 LP pilot 2) 2-00-73122 Igniter mount 3) 3-40-08220 Igniter (piezo) 4) 3-31-09100 90 degree street elbow 5) 3-40-09106 50% turn down LP valve 6) 3-31-08792 1/2” flare fitting 7) 3-44-73174 Valve gasket 8) 3-90-4273 Ga...
Page 26 - Turn on gas valve
26 TROUBLE SHOOTING Only For Qualified Installers Look through hole in end oflog to see if a spark jumpsfrom the ignitor electrode tothe pilot when the ignitorbutton is pushed. Check ignitor wire andconnections from piezo ignitorto ignitor ceramic at pilot. Reconnect or replaceIgnitor wire. Yes No B...
Page 27 - Check inlet pres s ure; Replace Valve; Correct inlet pres s ure
27 TROUBLE SHOOTING Only For Qualified Installers Good Good Check Milivolt output ofthermocouple. Shouldbe 10 or more MV. Check inlet pres s ure Bad Adjust pilot adjustment toachieve proper flame. Replace Thermocouple Bad Replace Valve Pilot does not stay lit Check size of pilot flames Bad Correct i...
Page 28 - Is Pilot lit; Replace valve
28 TROUBLE SHOOTING Only For Qualified Installers Main Burner willnot light (with valvein "on" position) Is Pilot lit no Light pilot Yes Check Thermopilevoltage at terminalsmarked TP on valve.Should be approximately200 mv with switch "on"and approximately 400mv with switch "off...
Page 29 - TROUBLE SHOOTING
29 TROUBLE SHOOTING Only For Qualified Installers A BLOWER KIT, PART NUMBER1-00-09102, MANUFACTURED BYHARMAN STOVE COMPANY,MAY BE USED WITH THISCONQUEST DIRECT VENT GAS Optional Blower Label This appliance has been converted for us e at an altitude of_______Feet Natural Propane Orifice Size 37 54 Ma...
Page 30 - Harman Gold Warranty
HARMAN GOLD WARRANTY6 YEAR TRANSFERABLE LIMITEDWARRANTY (Residential) 1 YEAR LIMITED WARRANTY (Commercial) 30 Harman Gold Warranty Harman Stove Company warrants its products to be free from defects in material or workmanship, in normal use and service, for a period of 6 years from the date of sales ...