Page 2 - 52 Mountain House Road; Requirements for Terminating the; Tested by; CONTENTS
2 Manufactured by: Harman Stove Co. 352 Mountain House Road Halifax, PA 17032 IN TR OD UC TI ON ..........................................3 I NS TALLATIO N ............................................4 Clearanc es ...........................................4 Ve nting ...................................
Page 3 - INTRODUCTION; or any other appliance.
3 INTRODUCTION The Harman Clarity Direct Vent 929DV Gas Heater is a listed gas-fired direct vent room heater tested by InchcapeTesting/Warnock Hersey to ANSI standard Z21.88-2002,CSA 2.33-M02, and CAN/CGA-2.17-M91. The installation of the Clarity Direct Vent Gas Heater must conform with local codes,...
Page 4 - learances; IMPORTANT NOTICE; INSTALLATION
4 C learances The following clearances to combustibles must be ob- served: Heater to left sidewall 9" (230 mm) Heater to right sidewall 9" (230 mm) Heater corner to walls 4" (100 mm) Heater to back wall 3" (75 mm) (measured from rear of heater to wall)Heater to alcove ceiling 18"...
Page 5 - Use Only Approved Venting; • Installation of any damaged Duravent GS component.; WARNING: The flow of ventilation air must not be; Horizontal and Vertical Venting Requirements; Roof Pitch; VENTING
5 Use Only Approved Venting The Clarity Direct Ven t Gas Heater has b een tested and is listed for installation with Simpson Duravent GS vent-ing components. The Simpson Duravent GS warranty willbe voided, and serious fire, health, or other safety hazardsmay result from any of the following actions:...
Page 6 - WARNING: Venting terminals must not be recessed; Connecting To An Existing Chimney
6 Requirements for Terminating the Venting WARNING: Venting terminals must not be recessed into a wall or siding. In addition, the following must be observed: A. The clearance above grade, or a veranda, porch, deck or balcony must be a minimum of 12" (30 cm). 1 B. The clearance to a window or do...
Page 7 - ASSEMBLY; Remove and Unwrap the Log Set
7 The Clarity is shipped from the factory with the log set packed inside the firebox. To prepare the stove for installa-tion, the log set must be unpacked, the appropriate burnersystem module for either natural gas or propane installed,and the logs installed. Removing the Glas s Front NOTE: The glas...
Page 8 - over the top of the rear burner—taking care that the top
8 With the module installed and secured, reach through the side access ports and plug in the electrical connections.(Two AMP Mate-N-Lok connectors). I nstall the Back Log and Back Brick Panel These two components are installed as a single piece. Rest the back brick panel on the shelf located on the ...
Page 9 - WARN ING: To avoid pipe c ompound s from en-; Gas Pressure Requirements; CONNECTING THE HEATER TO A GAS SUPPLY
9 Burn Only the Fuel for which the Heater is Equipped The Clarity Direct Vent will burn either natural gas or propane, but requires a dedicated burner system module foreither fuel. The label on the burner system module indicatesthe fuel for which it is equipped. A second label, locatednear the ratin...
Page 10 - Connecting the Cordset; WARNING: This heater is equipped with a three-; Connecting the Optional Thermostat; RECOM M ENDED WIRE GAUGES; Maximum; CONNECTING THE HEATER TO CORDSET
10 Connecting the Cordset The Clarity Direct Vent Gas Heater must be installed in accordance with local codes or, in the absence of local codes,with the most recent edition of the National Electrical CodeANSI/NFPA 70, or the current Canadian Electrical CodeC22.1. NOTE: The convection fan requires a ...
Page 11 - AIR SH UTTER ADJUSTM ENT; If the flam es d o no t resembl e th e descriptio n ab ove; Monitoring the Gas Flame; AIR SHUTTER ADJUSTMENT
11 AIR SH UTTER ADJUSTM ENT The final step of the installation is to check the flame pat- tern, which should resemble the pattern illustrated in theright column: The flames should be relatively well-definedand stable. They should be bright yellow with a blue basewhere attached to the burner ports, a...
Page 12 - HOW TO LIGHT THE F IRE; •If the knob does not pop up when released, stop and; HOW TO TURN OFF THE FIRE; NOTE: The knob cannot be turned from “PILOT” to; OPERATION
12 HOW TO LIGHT THE F IRE 1. STOP! Read the safety information on the left side of the panel on page 13. 2. If using the optional thermostat, set thermostat to the lowest setting. 3. Turn off electric power to the appliance.4. Turn the ON-OFF/THERMOSTAT switch to the OFF position. 5. Push in the gas...
Page 13 - SAFETY/LIGHTING LABEL
13 SAFETY/LIGHTING LABEL Evaluation notes were added to the output document. To get rid of these notes, please order your copy of ePrint IV now.
Page 14 - WARNIN G: N ever clean the glas s w hen it is ho t.; Inspecting the Venting; MAINTENANCE
14 A qualified service person recommended by your Har- man dealer should conduct an annual inspection and main-tenance of your Clarity, its venting, and the installation tokeep it running safely and efficiently. The following proce-dures should be performed only by a qualified service per-son. The g...
Page 15 - WIRING DIAGRAM
15 Clarity Direct Vent Wiring Diagram The Clarity Direct Vent gas heater, when ins talled, mus t be electrically grounded in accordance with currentlocal codes or, in the abs ence of local codes , with the current edition of National Electrical Code, ANSI/NFPA70 in the United States or the current C...
Page 16 - PARTS LIST
16 The following replacement parts for your Harman Clarity Direct Vent are available from your Harman dealer. 39. 40. 41. 42. 43. 44. 45. 46. 47. 48. 49 50. 51. 52. 53. 54a 54b.. 55. 56. 57. 58a. 58b. 59a. 60. 60b. 61. 62. 63. 64. 65. 66. 67. ID# 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16...
Page 18 - CLARITY BURNER MODULE : EXPLODED VIEW
18 CLARITY BURNER MODULE : EXPLODED VIEW 40 38 49 37 12 13 14 52 51 41 50 44 48 42 43 31 32 33 Evaluation notes were added to the output document. To get rid of these notes, please order your copy of ePrint IV now.
Page 19 - MINIMUM CLEARANCES F ROM COMB USTIBLE CONSTRUCTION; Unit to left sidewall; Harman Stove Company; SPECIFICATIONS
19 Tested to ANSI Z21.88-2002, CSA 2.33-M02, and CAN/CGA 2.17-M91. NATURAL GAS PROPANE Input Rating (Btu/hr) (0-4500 ft) (0-1375 m) 40,000 40,000 Min. Input Rating (Btu/hr) (0-4500 ft) (0-1375 m) 27,000 28,000 Injectors (DMS) (front/middle/rear) (0-4500 ft) (0-1375 m) 45/56/39 56/71/53 Manifold Pres...
Page 20 - N O TE: TH E C O N VER S I O N S H ALL B E CAR -; Conversion K it Components; • Burner system module; Remove the Log Set; bel—supplied with the burner system module—must be filled; APPENDIX A
20 Converting the Clarity Direct Ventfrom One Gas to Another in the Field N O TE: TH E C O N VER S I O N S H ALL B E CAR - R I ED O U T I N AC CO R D ANC E WI TH TH E R E-QUIREM ENTS OF THE PROVINCIAL OR LOCALAUTHORITIES HAVING JURISDICTION AND INACCORDANCE WITH REQUIREM ENTS OF THECU RRENT EDI TIO ...
Page 21 - De-rating for High Altitude; NATURAL GAS; APPENDIX B
21 De-rating for High Altitude For U.S. installations, the Clarity Direct Vent is approved for elevations up to 2000 feet using the factory-installed burner injectors. At elevations above 2000 feet, U.S. codes require a decrease in the input rating by changing the burner injectors toa smaller size. ...
Page 23 - Secure Vent Direct Vent System; Secure Vent Direct Ven t System
23 Secure Vent Direct Vent System Leng th 6" ( galval um e) SV4L6 908 SV5L6 1208 Len gth 6" (bla ck) SV4L B6 908B SV5L B6 1208B Len gth 1 2" (ga lvalu m e) SV4L 12 906 SV5L 12 1206 Len gth 12 " (bla ck) SV4LB12 906B SV5LB12 1206B Len gth 2 4" (ga lvalu m e) SV4L 24 904 SV5L 24 12...
Page 24 - HARMAN GOLD WARRANTY
24 Harman Stove Company warrants its products to be free from defects in material or workmanship, in normal use and service, for a period of 6 years from the date of sales invoice and for mechanical and electrical failures, in normal use and service,for a period of 3 years from the date of sales inv...