Page 2 - CONTENTS; and; Lumex; are registered trademarks of GF Health Products, Inc.
LF2020-INS-LAB-RevC12 2 CONTENTS 1 INTRODUCTION .............................................................................................................................. 32 SAFETY PRECAUTIONS ..........................................................................................................
Page 3 - INTRODUCTION; Intended use
LF2020-INS-LAB-RevC12 3 1 INTRODUCTION Congratulations on your purchase of the Lumex LF2020 Easy Lift Sit-to-Stand (STS) / LF2090 Bariatric Easy Lift Sit-to-Stand (STS). The following pages will provide you with important safety and operating instructions on the use of patient lifts, slings, and acc...
Page 4 - SAFETY PRECAUTIONS; CARE AND MAINTENANCE; Significance of safety statements; WARNINGS
LF2020-INS-LAB-RevC12 4 2 SAFETY PRECAUTIONS IMPORTANT: Before using patient lift, please read and adhere to the following safety precautions and warnings. Failure to do so could result in serious personal injur y or damage to your patient lift. Always consult your healthcare professional to determi...
Page 6 - FEATURES; CONTROL BOX FEATURES
LF2020-INS-LAB-RevC12 6 3 FEATURES EASY LIFT SIT-TO-STAND FEATURES Pendant Actuator Lifting Boom Knee Pad Footrest Base Brake Mast Control Box CONTROL BOX FEATURES RESET Button Battery Testing Battery Charger Plug-In Actuator Plug-In Pendant Plug-In
Page 7 - HANDLING PROCEDURES; SHIPPING AND TRANSPORTATION INSTRUCTIONS; Unpacking; from the box without assistance.; carrier or your Graham-Field distributor.; Inspection
LF2020-INS-LAB-RevC12 7 4 HANDLING PROCEDURES SHIPPING AND TRANSPORTATION INSTRUCTIONS If the patient lift is to be reshipped by common carrier, it should be packed in the same carton in which it was received. Unpacking WARNING: The lift is heavy. To avoid personal injur y, DO NOT attempt to remove ...
Page 8 - ASSEMBLY INSTRUCTIONS; lift without assistance.
LF2020-INS-LAB-RevC12 8 5 ASSEMBLY INSTRUCTIONS WARNING: The lift is heavy. To avoid personal injur y, DO NOT attempt to assemble the lift without assistance. 1. Remove the nuts and bolts from top and bottom of mast.2. With one hand on the mast and another on the boom, pull the mast to an upright po...
Page 9 - CHARGING THE BATTERIES; three hours to be fully charged.; NOTICE: Do not charge the batteries for more than twelve hours.; Unplug the charger FIRST before using the lift.; Important Charging Information; CHECKING BATTERY CAPACITY
LF2020-INS-LAB-RevC12 9 CHARGING THE BATTERIES Charge the batteries after assembly.1. Ensure the control box power switch is ON (i.e., the red button is up).2. Insert the charger plug into the battery box charging socket (the top slot).3. Insert the other charger plug into the power supply.4. All LE...
Page 10 - OPERATING INSTRUCTIONS; the lift in the widest position.; Preparation before lifting; to ensure the lift is operating correctly.; movements, or patients with limited postural control.
LF2020-INS-LAB-RevC12 10 6 OPERATING INSTRUCTIONS WARNING: During lifting and lowering, whenever possible, always keep the base legs of the lift in the widest position. WARNING: Use only Lumex slings specially designed for the LF2020 Easy Lift STS / LF2090 Bariatric Easy Lift STS. WARNING: DO NOT us...
Page 11 - LIFTING THE PATIENT; stop and possibly tip the patient lift.; Lift and transfer from bed; should be in the maximum open position.; them hold their arms around the chest.
LF2020-INS-LAB-RevC12 11 LIFTING THE PATIENT WARNING: Do not attempt to transfer a patient without prior approval of the patient’s healthcare professional and without having read the instructions and practiced using the patient lift. WARNING: Ensure the floor area is clear of any obstacle that could...
Page 12 - Lift and transfer from chair; transferring a patient to and from a wheelchair.
LF2020-INS-LAB-RevC12 12 Lift and transfer from chair WARNING: GF Health Products, Inc. recommends that two attendants be used when transferring a patient to and from a wheelchair. WARNING: Before transfer, ensure wheelchair wheel locks are in locked position. Wheelchair wheel locks must be in LOCKE...
Page 13 - CARE AND MAINTENANCE; BEFORE EACH USE
LF2020-INS-LAB-RevC12 13 7 CARE AND MAINTENANCE Proper care and maintenance are essential to keeping your Lumex LF2020 Easy Lift STS / LF2090 Bariatric Easy Lift STS in a safe operating condition. In addition to inspecting the unit before each use, periodic maintenance checks should be done. We furt...
Page 14 - MAINTENANCE SCHEDULE
LF2020-INS-LAB-RevC12 14 MAINTENANCE SCHEDULE Info: Only qualified persons should service and repair your Lumex LF2020 Easy Lift STS / LF2090 Bariatric Easy Lift STS. Regular maintenance of your patient lift is necessar y to ensure continuing proper and safe operation. Read and observe the following...
Page 15 - TROUBLESHOOTING
LF2020-INS-LAB-RevC12 15 8 TROUBLESHOOTING The following list of encountered problems and their solutions will assist you in determining what may be causing your Lumex lift not to function as designed. If you have a problem occurring which is not listed below, please contact your distributor or Grah...
Page 16 - SPECIFICATIONS
LF2020-INS-LAB-RevC12 16 9 SPECIFICATIONS Info: All dimensions are given in inches unless otherwise specified. Base width Open: 43"Closed: 26" Base height clearance 6" Overall base length 50" Lifting height range Info: As measured from sling hooks. Minimum: 27"Maximum: 71"Ran...
Page 17 - 0 LIMITED WARRANTY; GF Health Products Inc.
LF2020-INS-LAB-RevC12 17 10 LIMITED WARRANTY GF Health Products Inc. (“Graham-Field”) warrants this product to be free from manufacturing defects in material and workmanship for its period of warranty that is in accordance with industry standards. This warranty is extended only to the original purch...