Page 2 - Labtron; CONTENTS
Labtron Digital Blood Pressure Monitor 2 Graham-Field and Labtron are registered trademarks of GF Health Products, Inc. Packaging, warranties, products, and specifications are subject to change without notice. GF Health Products, Inc. is not responsible for typographical errors. CONTENTS SAFETY GUID...
Page 3 - SAFETY GUIDELINES - PLEASE READ BEFORE USE
Labtron Digital Blood Pressure Monitor 3 SAFETY GUIDELINES - PLEASE READ BEFORE USE Important! Read and understand these instructions before using the Labtron Digital Blood Pressure Monitor. If you do not understand any part of these instructions, contact your medical professional or Graham-Field de...
Page 4 - FEATURES; Digital Blood Pressure Monitor
Labtron Digital Blood Pressure Monitor 4 FEATURES Main features of the Digital Blood Pressure Monitor, referred to in this manual, are shown in the picture at right. cuff cuff hose LCD bulb ON/OFF button exhaust valve button Digital Blood Pressure Monitor
Page 5 - BATTERY INSTALLATION / REPLACEMENT; Blood Pressure
Labtron Digital Blood Pressure Monitor 5 BATTERY INSTALLATION / REPLACEMENT 1. Slide the battery cover off in the direction of the arrow. 2. Install or replace the four AAA batteries, oriented as shown by battery compartment diagram, into the battery compartment. 3. Replace the battery cover. Ensure...
Page 6 - diastolic pressure; ) shows the lowest pressure in the; Preparing to measure blood pressure; Blood pressure fluctuates continuously throughout the day. To
Labtron Digital Blood Pressure Monitor 6 in the arteries occurring when the heart contracts. The lower reading ( diastolic pressure ) shows the lowest pressure in the arteries, which occurs right before the heart contracts. Blood pressure readings are written with the highest value first, then the l...
Page 7 - Remove any clothing on the upper arm to place the
Labtron Digital Blood Pressure Monitor 7 beverages, before a measurement. 4. Remove any clothing on the upper arm to place the cuff directly on the skin. Constriction of the upper arm by clothing or a rolled-up sleeve, as shown at right, may cause an inaccurate reading; remove any constricting garme...
Page 8 - Hold the area of the cuff where; Never place the cuff over; Pull the opposite end of the cuff snugly
Labtron Digital Blood Pressure Monitor 8 7. Attach the cuff: Hold the area of the cuff where the hose exits the cuff firmly against the inside of the bare upper arm directly over the brachial artery, and the bottom of the cuff approximately one inch (2-3cm) above the elbow, as shown in the third pic...
Page 9 - Measuring blood pressure; described in previous paragraphs.
Labtron Digital Blood Pressure Monitor 9 Measuring blood pressure Symbol key: LCD symbols you may see during measurement Deflating Inflating Measurement error Measuring Low battery 1. Ensure that cuff is properly placed and that you are positioned as described in previous paragraphs. 2. Press the ON...
Page 10 - tter y symbol will also appear at this time while the; To accelerate
Labtron Digital Blood Pressure Monitor 10 Info: The low ba tter y symbol will also appear at this time while the monitor checks the power level. This does not indicate that the batteries are low unless the low batter y symbol remains on continuously. 3. After "0" displays, pressurize the cuf...
Page 11 - The device will automatically shut off three minutes after
Labtron Digital Blood Pressure Monitor 11 Info: To stop measurement in progress for whatever reason, press the exhaust valve button to release the pressure and turn off the device.Info: If during measurement the power drops to an insufficient level, the device will end the measurement and display th...
Page 12 - If performing measurement for the first time, repeat the; Only your physician is qualified to analyze
Labtron Digital Blood Pressure Monitor 12 7. If performing measurement for the first time, repeat the measurement two or more times to ensure that you and cuff are positioned correctly and that results are accurate and consistent. Record your results; there is a log provided, with examples, at the e...
Page 13 - MAINTENANCE; Do not dismantle or disassemble monitor components.
Labtron Digital Blood Pressure Monitor 13 MAINTENANCE s NOTICE: To prevent product damage, please follow these recommended care and maintenance instructions: Do not drop or pull excessively on monitor components or subject them to strong impact. Do not use monitor close to any device with a strong e...
Page 14 - while remaining still
Labtron Digital Blood Pressure Monitor 14 TROUBLESHOOTINGError indicators Indication Cuff pressure reaches 330mmHg Cause Twisted bladder inside cuff Correction Ensure that bladder lies flat within cuff Indication "Err" displays, cuff pressure releases, then "0 pressure" displays Caus...
Page 15 - General troubleshooting; Problem
Labtron Digital Blood Pressure Monitor 15 General troubleshooting Problem Recommended Action Nothing appears in LCD Ensure that batteries are correctly oriented in battery holder (polarity matches battery case placement indicators) No measurement occurs Ensure that cuff is positioned correctlyGo ove...
Page 18 - WARRANTY
Labtron Digital Blood Pressure Monitor 18 WARRANTY GF Health Products, Inc. ("Graham-Field") warrants the Labtron Digital Blood Pressure Monitor Model 707A/707A X/707A C for a period of one year for defects in workmanship and materials. If a product is deemed to be under warranty, GF Health ...
Page 19 - BLOOD PRESSURE MEASUREMENT LOG
Labtron Digital Blood Pressure Monitor 19 BLOOD PRESSURE MEASUREMENT LOG Date Time Pulse Body Condition 1/1 1/1 1/1 60 80 100 120 140 160 180 200 220 240 mmHg 128 134 123 84 90 76 70 73 69 7:00 13:30 20:00
Page 20 - USA Corporate Headquarters:
USA Corporate Headquarters: GF Health Products, Inc. 2935 Northeast Parkway Atlanta, Georgia 30360 telephone: 770-368-4700 fax: 770-368-2386 www.grahamfield.com 707A-INS-LAB-RevD11 © 2011, GF Health Products, Inc.