Page 3 - Symbols; Warning Symbol; Caution Symbol; CAUTION; WARNING; EQUIPMENT MISUSE HAZARD; PRESSURIZED EQUIPMENT HAZARD
310564 3 Symbols Warning Symbol WARNING This symbol alerts you to the possibility of seriousinjury or death if you do not follow the instructions. Caution Symbol CAUTION This symbol alerts you to the possibility of damage toor destruction of equipment if you do not follow theinstructions. WARNING IN...
Page 4 - MOVING PARTS HAZARD; FIRE AND EXPLOSION HAZARD; TOXIC FLUID HAZARD
4 310564 WARNING MOVING PARTS HAZARD Moving parts, such as the air motor piston, can pinch or amputate your fingers. D Keep clear of all moving parts when starting or operating the pump. D Before servicing the equipment, follow the Pressure Relief Procedure on page 10 to prevent the equipment from s...
Page 5 - Component Identification
310564 5 Component Identification TI0957 Fig. 1 Model 96A637 Shown KEY A Pump InletB Fluid Gauge and DampenerC Fluid Gauge Ball ValveD Fluid FilterE Filter Ball ValveF Fluid Drain ValveG Air Supply InletH Air Filter Side View J Fluid Surge Tank K Air Motor Master Air ValveL Air Regulator and GaugeM ...
Page 6 - Setup; Site Preparation
6 310564 Setup WARNING To reduce the risk of serious injury whenever youare instructed to relieve pressure, always follow the Pressure Relief Procedure on page 10. Site Preparation Fig. 1. Relieve system pressure. For installing any one of the packages listed in this manual, select a sitewith at lea...
Page 8 - Connect the Fluid Lines
8 310564 Setup Connect the Fluid Lines Fig. 1. Connect system fluid supply line to the circula-tion package at fluid supply inlet (A). Close filter ballvalves (E) to isolate the circulation package from themain fluid supply line. Connect circulation package to the system fluid returnline at fluid re...
Page 10 - Operation
10 310564 Operation Pressure Relief Procedure WARNING PRESSURIZED EQUIPMENT HAZARD The system pressure must be manually relieved toprevent the system from starting or spraying acci-dentally. To reduce the risk of an injury from acci-dental spray from the gun, splashing fluid, ormoving parts, follow ...
Page 12 - Starting and Adjusting the Pump; Shutdown
12 310564 Operation Starting and Adjusting the Pump 1. Fig. 4. Open all fluid shutoff valves (5–two). Makesure Air Regulator (CC) is fully closed. 2. Open the spray gun at the last gun station andkeep it open while starting the pump. 3. Open the bleed-type master air valves (W, AA). 4. Slowly open a...
Page 13 - Maintenance; Preventive Maintenance Schedule; Fluid Filter Service
310564 13 Maintenance Preventive Maintenance Schedule The operating conditions of your particular systemdetermine how often maintenance is required. Estab-lish a preventive maintenance schedule by recordingwhen and what kind of maintenance is needed, andthen determine a regular schedule for checking...
Page 14 - Air Filter Service
14 310564 Maintenance Air Filter Service 1. Fig. 4. Every day, drain contaminants from thebowl before reaching the baffle level by openingthe drain at the bottom of the bowl (BB). WARNING To reduce the risk of serious injury whenever youare instructed to relieve pressure, always follow the Pressure ...
Page 15 - Troubleshooting
310564 15 Troubleshooting WARNING To reduce the risk of serious injury whenever you are instructed to relieve pressure, always followthe Pressure Relief Procedure (page 10). For pump service see pump manual. Problem Cause(s) Solution(s) Pump output low on both strokes Restricted air or hydraulic lin...
Page 16 - Parts
16 310564 Parts Right Hand Mount Model: 96A6374:1 Ratio, Glutton Pump TI0957 11 13 14 14 5 4,3 24 5,4,3 14 19 53,21,20 12,4,3 22 13 51 7 35 50 36 45 43 4,3,2 1 1516 17 23 3,4 14 Ref Ref 5 Detail A Detail A 51 Ref 50 Ref 49 48 47 46 Ref 43 Ref 37,38,39 42 35 10 46 31 52 25,26,27 32,33,34 30 44 54
Page 26 - :1 Ratio Glutton Pumps; Performance Chart
26 310564 Technical Data 4:1 Ratio Glutton Pumps Category Data Maximum Fluid Working Pressure 2.4 MPa, 24.5 bar (350 psi) Air Operating Range 0.17–0.6 MPa, 1.7 – 6.2 bar (25 – 90 psi) Fluid Flow at 60 Cycles per Minute 21.2 liter/min (5.6 gpm) Cycles Per Liter (gallon) 2.7 (10.4) Maximum Recommended...
Page 27 - Notes
Page 28 - Dimensions
28 310564 Dimensions Mount the circulation package so the top of thebracket is 5 to 6 ft (1.5 to 1.8 m) above the floor. 1 Ensure that there is 5 ft (1.5 m) overhead clearance for wall mounted systems and at least 7 ft (2.1 m) forfloor mounted systems. 2 1 2 Model 96A637 Shown TI0957
Page 29 - Mounting Hole Layout
310564 29 Mounting Hole Layout 1 Check that the wall frame is level before bolting it to the wall. 2 Mount the wall frame so the top edge is 5 to 6 ft (1.5 to 1.8 m) above the floor. 2 27.0 in. (685.8 mm) Wall Frame 618313 1 3/8 in. (8) places 0.5 in. (12.7 mm) 31.0 in. (787.4 mm) 3.0 in. (76.2 mm) ...
Page 30 - Graco Standard Warranty; Graco Information
30 310564 Graco Standard Warranty Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on thedate of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco,Grac...