Page 2 - Warnings; WARNING
Warnings 2 3A1215C Warnings The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama-tion point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When these symbols appear in the body of this manua...
Page 3 - Component Identification and Function
Component Identification and Function 3A1215C 3 Component Identification and Function Switch / Indicator Explanation A - F Menu Controls Provides menu specific commands as display on LCD screen. Provides skipline paint and cycle distance storage for instant change. Press and hold button to store pat...
Page 4 - Installation; Connect the Control Cable; Operation; General
Installation 4 3A1215C Installation Mount Programmable Skipline Control Place the Control in a position that is comfortable and easy to use. If you decide to mount the control, mount the 0.50” (13mm) wide mounting bracket to a solid loca-tion. Connect the Control Cable Clean all connections of dirt,...
Page 5 - Menus; Application Totals
Operation 3A1215C 5 Menus Information Readout (Startup/Main Menu) Measuring Counter: Resets every time HOLD/RESET is activated. The First Menu is used to set the paint length of a skip line and the frequency of that length. 1. Set paint length with adjacent arrows.2. Set cycle length with adjacent a...
Page 6 - Distance Calibration; Pump Calibration
Operation 6 3A1215C Distance Calibration The Distance Calibration Menu is used to calibrate the system against a measured distance (see Distance Calibration Procedure , page 9). 1. Use adjacent arrows to enter the length of the mea- sured course. 2. Press at the beginning of the measured course. 3. ...
Page 7 - Setup
Operation 3A1215C 7 Setup Distance Units A Distance Units Bead Gun Enable/Disable Adjust Display Contrast Display SPACE or CYCLE GALLONS or LITERS B C D E System Type F A B A English ft/in/mphMetric m/cm/kph C Exit Changing units will reset to factory settings Bead Gun Solenoids B A Solenoid 2 ENABL...
Page 8 - Marker Layout Mode; Diagnostics
Operation 8 3A1215C Marker Layout Mode Change Value Set space sizes up to 8 consecutive measurements. By leav-ing zeros in any space, Marker Layout Mode will skip to the next measurement in a continuous loop. DOT Size (sec) The amount of time the gun will be activated. NOTE: Lowering system pressure...
Page 9 - Distance Calibration Procedure
Operation 3A1215C 9 Distance Calibration Procedure NOTE: Although the RoadLazer is calibrated prior to shipping, the sensor will need to be recalibrated periodi-cally due to wheel wear, and also whenever the gun-arm wheel is replaced. NOTE: Before recalibrating, ensure that the gun-arm wheel is infl...
Page 10 - On
Operation 10 3A1215C Example: Painting Two Solid Lines with the One-Operator System Delay ™ On 1. Turn on System Delay. 2. Set guns 1 and 2 in the solid position and the RESET/HOLD switch in the hold position. 3. Align the mechanical reference point with the begin- ning of the area to be painted (A)...
Page 12 - Troubleshooting
Troubleshooting 12 3A1215C Troubleshooting Problem Cause Solution Control will not turn on. 12 VDC power supply low, or discon-nected. Connect the I/O cable. Charge the RoadLazer battery. Check the battery connections. Guns will not spray. Various causes. Toggle RESET on the controller. Check the pa...
Page 14 - Parts
Parts 14 3A1215C Parts Technical Data PO W ER ON OFF RE SE T HOLD BE ADS O N BEA D TES T A B C D E F SY ST EM DE LA Y ST AR T SK IP SP AC E ME NU ME NU PR OG RAM MA BLE SKIPLINE CO NT RO L PO W ER ON OF F RE SET HO LD BEAD S ON BE AD TE ST A B C D E F SY ST EM DE LA Y ST AR T SK IP SP AC E ME NU ME ...
Page 15 - Notes
Page 16 - Graco Standard Warranty; Graco Information
All written and visual data contained in this document reflects the latest product information available at the time of publication. Graco reserves the right to make changes at any time without notice. For patent information, see www.graco.com/patents Original instructions. This manual contains Engl...