Page 2 - Installation; TRAY FILL INSTALLATION

2 308439 Installation The Split Manifold Kit enables you to convert theHusky 307 Pump to a dual fluid inlet manifold, dualfluid outlet manifold, or both. See Figs. 1, 2, and 3 forsome applications. To install the kit, see page 3. NOTE: To convert both the inlet and the outletmanifold, two kits are r...

Page 3 - Installation Procedure; WARNING; Follow the Pressure Relief Procedure above.

308439 3 Installation Installation Procedure WARNING Pressure Relief ProcedureTo reduce the risk of serious injury, includingsplashing fluid or solvent in the eyes or on the skin,follow this procedure before installing this kit. 1. Shut off the air to the pump. 2. Open the dispensing valve, is used....

Page 4 - Installing a Split Outlet Manifold

4 308439 Installation 03912 Fig. 4 1 Part of pump; not supplied in kit. 2 3 1 1 3 3 1 1 3 2 A A D A D A 1 1 1 Installing a Split Outlet Manifold Installing a Split Inlet Manifold B 1 B 1 C C 2 Apply thread lubricant. 3 Torque to 50–60 in-lb (5.6–6.8 N S m). Do not over-torque. 2 3 1 2 3 1 2 3 1 2 3 ...