Page 3 - GENERAL INFORMATION; SAFETY INFORMATION; WARNING; ILLUSTRATION REFERENCES

GENERAL INFORMATION The Model 1206 Dispense Valve is engineered for applications which require volumetric consistency. The 1206 allows operation with material supply pressures up to 100 psi (6.9 bar). Material viscosity dis pensing capabilities range from very thin material to high - viscosity epoxi...

Page 4 - DESCRIPTION OF OPERATION; SETUP PROCEDURE; MOUNTING DISPENSE VALVE

DESCRIPTION OF OPERATION The 1206 Dispense Valve is a positive displacement valve that requires continuous material feed. The operation of the valve is as follows: Material enters the Dispense Valve through the material inlet port located on the metering rod/sleeve assembly and fills the dispense ca...

Page 5 - OPERATING PROCEDURES; WET SYSTEM CHECKOUT

OPERATING PROCEDURES DRY SYSTEM CHECKOUT This is an initial checkout to find if the system setup is complete. Conduct the dry system checkout without material in the system. Attach the pneumatic pressure lines from the dispense valve to the air supply controller. Turn on the electric and air supply....