Page 2 - INSTALLATION INSTRUCTIONS; F, it is important to insure a positive head; IMPORTANT OPERATING CONDITIONS; Crankcase oil should be changed after the

INSTALLATION INSTRUCTIONS 4. Use of a dampener is necessary to minimizepulsation at drive elements, plumbing, connec-tions, and other system areas. The use of adampener with Giant Industries, Inc. pumps isoptional, although recommended by GiantIndustries, Inc. to further reduce system pulsa-tion. Da...

Page 3 - In order to drive the pump from the side opposite the present shaft; We recommend a 1.15 service factor; REQUIREMENTS; Specifications

NOTES: 1 In order to drive the pump from the side opposite the present shaft extension, simply remove the valve casing from the crankcase androtate the pumps 180 degrees to the desired position. Be certain torotate the seal case (item #20) as well, so that the weep holes aredown at the six o'clock p...

Page 7 - Contact Giant Industries or your local; 3) Generously lubricate

9) Check surfaces of plunger pipe (16B). REASSEMBLY INSTRUCTIONS - P420A-3100/5100 PUMPS 11) Place pressure rings and weep seals (23B) overplungers and into each sealcase (20). 12) Place weep return rings (25) over the plunger (16) andpressure ring over plunger(24). Contact Giant Industries or your ...