Page 2 - INSTALLATION INSTRUCTIONS; IMPORTANT OPERATING CONDITIONS; Crankcase oil should be changed after the
2 INSTALLATION INSTRUCTIONS 4. Use of a dampener is necessary to minimizepulsation at drive elements, plumbing, connec-tions, and other system areas. The use of adampener with Giant Industries, Inc. pumps isoptional, although recommended by GiantIndustries, Inc. to further reduce system pulsa-tion. ...
Page 3 - P205 HORSEPOWER REQUIREMENTS; Specifications; Metric; Positive inlet pressure required
P205 HORSEPOWER REQUIREMENTS RPM GPM 1000 PSI 1500 PSI 2000 PSI 2500 PSI* 500 0.13 0.1 0.1 0.2 0.2 1000 0.29 0.2 0.3 0.4 0.5 1750 0.50 0.3 0.5 0.7 0.9 3000 0.78 0.5 0.8 1.1 1.4 3200 0.84 0.6 0.9 1.2 1.4 3450 0.90 0.6 0.9 1.2 1.6 3 Specifications Model P205 1750 RPM + ...................................
Page 4 - P206 HORSEPOWER REQUIREMENTS; We recommend a 1.15 service factor; *Intermittent duty only
P206 HORSEPOWER REQUIREMENTS RPM GPM 1000 PSI 1500 PSI 2000 PSI 2500 PSI* 250 0.11 0.1 0.1 0.2 0.2 500 0.21 0.1 0.2 0.3 0.4 1000 0.43 0.3 0.4 0.6 0.7 1750 0.76 0.5 0.8 1.0 1.3 3000 1.30 0.9 1.3 1.8 2.2 3200 1.40 1.0 1.4 1.9 2.4 3450 1.50 1.0 1.6 2.1 2.6 Specifications Model P206 NOTE: In order to dr...
Page 5 - P207 HORSEPOWER REQUIREMENTS
P207 HORSEPOWER REQUIREMENTS RPM GPM 1000 PSI 1500 PSI 2000 PSI 2500 PSI* 500 0.26 0.2 0.3 0.4 0.4 1000 0.51 0.4 0.5 0.7 0.9 1750 0.90 0.6 0.9 1.2 1.6 3000 1.48 1.0 1.5 2.0 2.6 3200 1.58 1.1 1.6 2.2 2.7 3450 1.70 1.2 1.8 2.3 2.9 5 Specifications Model P207 NOTE: In order to drive the pump from the s...
Page 6 - P208 HORSEPOWER REQUIREMENTS
P208 HORSEPOWER REQUIREMENTS RPM GPM 1000 PSI 1500 PSI 2000 PSI 2500 PSI* 250 0.14 0.1 0.1 0.2 0.2 500 0.29 0.2 0.3 0.4 0.5 1000 0.57 0.4 0.6 0.8 1.0 1750 1.00 0.7 1.0 1.4 1.7 3000 1.60 1.1 1.7 2.2 2.8 3200 1.80 1.2 1.9 2.5 3.1 3450 1.90 1.3 2.0 2.6 3.3 6 Specifications Model P208 NOTE: In order to ...
Page 7 - P209 HORSEPOWER REQUIREMENTS
P209 HORSEPOWER REQUIREMENTS RPM GPM 1000 PSI 1500 PSI 2000 PSI 2500 PSI* 500 0.43 0.3 0.4 0.6 0.7 1000 0.86 0.6 0.9 1.2 1.5 1750 1.50 1.0 1.6 2.1 2.6 3000 2.35 1.6 2.4 3.2 4.0 3200 2.50 1.7 2.6 3.4 4.3 3450 2.70 1.9 2.8 3.7 4.7 7 Specifications Model P209 Consult the factory for special requirement...
Page 8 - P210 HORSEPOWER REQUIREMENTS
P210 HORSEPOWER REQUIREMENTS RPM GPM 1000 PSI 1500 PSI 2000 PSI 2500 PSI* 250 0.26 0.2 0.3 0.4 0.4 500 0.51 0.4 0.5 0.7 0.9 1000 1.03 0.7 1.1 1.4 1.8 1750 1.80 1.2 1.9 2.5 3.1 3000 2.87 2.0 3.0 4.0 5.0 3200 3.06 2.1 3.2 4.2 5.3 3450 3.30 2.3 3.4 4.6 5.7 8 Specifications Model P210 NOTE: In order to ...
Page 9 - P211 HORSEPOWER REQUIREMENTS
P211 HORSEPOWER REQUIREMENTS RPM GPM 1000 PSI 1500 PSI 2000 PSI 2500 PSI* 500 0.60 0.4 0.6 0.8 1.0 1000 1.20 0.8 1.2 1.7 2.1 1750 2.10 1.4 2.2 2.9 3.6 3000 3.30 2.3 3.4 4.6 5.7 3200 3.52 2.4 3.6 4.9 6.1 3450 3.80 2.6 3.9 5.2 6.5 9 Specifications Model P211 Consult the factory for special requirement...
Page 12 - Plunger Packing Kit
Position Item# Description Torque Amount 32 07928 Valve Plug 59 (ft.-lbs.) 34 08316 Hex Head Cap Screw, Valve Casing 105 (in.-lbs.) Plunger Packing Kit Part # 09527 Item # Part # Description Qty. 23 07391 V-Sleeve, weep 3 23A 08598 V-Sleeve 3 24 07392 Support Ring 3 Oil Seal Kit Part # 09144 Item # ...
Page 14 - If the ceramic plunger pipe
14 Reassembly sequence of the P205/P206/P207/P208/P209/P210/P211 PUMPS 1) If oil seals (19) were removed, replace with seal lip towards crankcase. Lubricate seals before replacing.Contact Giant for assistance with the reassembly of the gear end. 2) Replace seal case (20) with o-rings (21) over plung...
Page 16 - GIANT INDUSTRIES LIMITED WARRANTY
07/07 P200_12mm.PM6 GIANT INDUSTRIES LIMITED WARRANTY Giant Industries, Inc. pumps and accessories are warranted by the manufacturer to be free from defects in workmanship and material as follows: 1. For portable pressure washers and self-serve car wash applications, the discharge manifolds will nev...