Page 2 - INSTALLATION INSTRUCTIONS; IMPORTANT OPERATING CONDITIONS; Crankcase oil should be changed after the

2 INSTALLATION INSTRUCTIONS 4. Use of a dampener is necessary to minimizepulsation at drive elements, plumbing, connec-tions, and other system areas. The use of adampener with Giant Industries, Inc. pumps isoptional, although recommended by GiantIndustries, Inc. to further reduce system pulsa-tion. ...

Page 3 - P205 HORSEPOWER REQUIREMENTS; Specifications; Metric; Positive inlet pressure required

P205 HORSEPOWER REQUIREMENTS RPM GPM 1000 PSI 1500 PSI 2000 PSI 2500 PSI* 500 0.13 0.1 0.1 0.2 0.2 1000 0.29 0.2 0.3 0.4 0.5 1750 0.50 0.3 0.5 0.7 0.9 3000 0.78 0.5 0.8 1.1 1.4 3200 0.84 0.6 0.9 1.2 1.4 3450 0.90 0.6 0.9 1.2 1.6 3 Specifications Model P205 1750 RPM + ...................................

Page 4 - P206 HORSEPOWER REQUIREMENTS; We recommend a 1.15 service factor; *Intermittent duty only

P206 HORSEPOWER REQUIREMENTS RPM GPM 1000 PSI 1500 PSI 2000 PSI 2500 PSI* 250 0.11 0.1 0.1 0.2 0.2 500 0.21 0.1 0.2 0.3 0.4 1000 0.43 0.3 0.4 0.6 0.7 1750 0.76 0.5 0.8 1.0 1.3 3000 1.30 0.9 1.3 1.8 2.2 3200 1.40 1.0 1.4 1.9 2.4 3450 1.50 1.0 1.6 2.1 2.6 Specifications Model P206 NOTE: In order to dr...