Summary

Page 2 - INSTALLATION INSTRUCTIONS

2 INSTALLATION INSTRUCTIONS 4. Use of a dampener is necessary to minimize pulsation at drive elements, plumbing, connec- tions, and other system areas. The use of a dampener with Giant Industries, Inc. pumps is optional, although recommended by Giant Industries, Inc. to further reduce system pulsa- ...

Page 3 - P217A HORSEPOWER REQUIREMENTS; Specifications; In order to drive the pump from the side opposite the present; *Intermittent duty only

P217A HORSEPOWER REQUIREMENTS RPM GPM 1000 PSI 1500 PSI 2000 PSI 2320 PSI*1725 1.7 1.2 1.8 2.3 2.7 3000 3.0 2.1 3.1 4.2 4.8 3200 3.2 2.2 3.3 4.4 5.1 3450 3.4 2.3 3.5 4.7 5.4 3 Specifications Model P217A NOTE: In order to drive the pump from the side opposite the present shaft extension, simply remov...

Page 4 - P218A HORSEPOWER REQUIREMENTS

P218A HORSEPOWER REQUIREMENTS RPM GPM 1000 PSI 1500 PSI 2000 PSI 2320 PSI*1 150 2.2 1.5 2.3 3.1 3.6 1 450 2.8 1.9 2.9 3.9 4.5 1 750 3.4 2.3 3.5 4.7 5.4 4 NOTE: In order to drive the pump from the side opposite the present shaft extension, simply remove the valve casing from the crank- case and rotat...