Page 2 - INSTALLATION INSTRUCTIONS
2 INSTALLATION INSTRUCTIONS 4. Use of a dampener is necessary to minimize pulsation at drive elements, plumbing, connec- tions, and other system areas. The use of a dampener with Giant Industries, Inc. pumps is optional, although recommended by Giant Industries, Inc. to further reduce system pulsa- ...
Page 3 - P217A HORSEPOWER REQUIREMENTS; Specifications; In order to drive the pump from the side opposite the present; *Intermittent duty only
P217A HORSEPOWER REQUIREMENTS RPM GPM 1000 PSI 1500 PSI 2000 PSI 2320 PSI*1725 1.7 1.2 1.8 2.3 2.7 3000 3.0 2.1 3.1 4.2 4.8 3200 3.2 2.2 3.3 4.4 5.1 3450 3.4 2.3 3.5 4.7 5.4 3 Specifications Model P217A NOTE: In order to drive the pump from the side opposite the present shaft extension, simply remov...
Page 4 - P218A HORSEPOWER REQUIREMENTS
P218A HORSEPOWER REQUIREMENTS RPM GPM 1000 PSI 1500 PSI 2000 PSI 2320 PSI*1 150 2.2 1.5 2.3 3.1 3.6 1 450 2.8 1.9 2.9 3.9 4.5 1 750 3.4 2.3 3.5 4.7 5.4 4 NOTE: In order to drive the pump from the side opposite the present shaft extension, simply remove the valve casing from the crank- case and rotat...
Page 5 - P219A HORSEPOWER REQUIREMENTS
P219A HORSEPOWER REQUIREMENTS RPM GPM 1000 PSI 1500 PSI 2 000 PSI 2320 PSI*1 150 2.7 1.9 2.8 3.8 4.4 1 450 3.5 2.4 3.6 4.8 5.5 1 750 4.2 2.9 4.3 5.8 6.7 5 Specifications Model P219A NOTE: In order to drive the pump from the side opposite the present shaft extension, simply remove the valve casing fr...
Page 6 - P220A HORSEPOWER REQUIREMENTS
P220A HORSEPOWER REQUIREMENTS RPM GPM 1000 PSI 1500 PSI 1700 PSI 2000 PSI* 2320 PSI*1150 3.1 2.1 3.2 3.6 4.2 4.9 1450 3.9 2.7 4.0 4.5 5.3 6.2 1750 4.7 3.2 4.8 5.5 6.4 7.4 6 Specifications Model P220A NOTE: In order to drive the pump from the side opposite the present shaft extension, simply remove t...
Page 7 - P221A HORSEPOWER REQUIREMENTS
P221A HORSEPOWER REQUIREMENTS RPM GPM 1000 PSI 15 00 PSI 2000 PSI* 2320 PSI*1 150 1.4 1.0 1.5 2.0 2.3 1 450 1.8 1.3 1.9 2.5 2.9 1 750 2.2 1.5 2.3 3.0 3.5 7 Specifications Model P221A Volume ........................................................................................................ Up to...
Page 8 - Exploded View - P200A Series
Page 9 - P200A SERIES PARTS LIST
9 ITEM PART NO. DESCRIPTION QTY. 16B 08455 Plunger Pipe (Excluding P223) 3 16B 07778 Plunger Pipe (P223 Only) 3 16C 08456 Tension Screw 3 16D 07676 Copper Gasket 3 17 08442 Wrist Pin 3 18 07770 O-Ring 3 19 08356-0010 Oil Seal 3 20 08444 Seal Case (Excluding P223) 3 20 06563 Seal Case (P223 Only) 3 2...
Page 10 - REQUIREMENTS
P223A HORSEPOWER REQUIREMENTS RPM GPM 1000 PSI 2000 PSI 2320 PSI*1 750 1.5 1 .0 2.1 2.4 3 200 2.8 1 .9 3.8 4.5 3 450 3.0 2 .1 4.1 4.8 10 Specifications Model P223A Volume ........................................................................................................ Up to 3.0 GPM Discharge ...
Page 12 - PUMP SYSTEM MALFUNCTION
12 PUMP SYSTEM MALFUNCTION MALFUNCTION The Pressure and/or the Delivery Drops Water in crankcase Noisy Operation Rough/Pulsating Operation with Pressure Drop Pressure Drop at Gun Excessive Leakage High Crankcase Temperature CAUSE Worn packing seals Broken valve spring Belt slippage Worn or Damaged n...
Page 13 - REPAIR INSTRUCTIONS - P200A SERIES
13 NOTE: Always take time to lubricate all metal and nonmetal parts with a light film of oil before reassembly. This step will ensure proper fit, at the same time protecting the pump nonmetal parts (i.e., the elastomers) from cutting and scoring. 1. With a 22mm socket wrench, remove the (3) discharg...
Page 16 - GIANT INDUSTRIES LIMITED WARRANTY
GIANT INDUSTRIES LIMITED WARRANTY Giant Industries, Inc. pumps and accessories are warranted by the manufacturer to be free fromdefects in workmanship and material as follows: 1. For portable pressure washers and self-serve car wash applications, the discharge manifolds will never fail, period. If t...