Comments… Suggestions… Corrections… The User Documentation Department would like toknow your opinion of this manual. Your feedback helpsus optimize our documentation to suit your individual needs. Feel free to send us your comments by e-mail to [email protected] . Certified documentation accord...
BX600 S3 Operating Manual Contents 1 Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 1.1 Overview of the Documentation . . . . . . . . . . . . . . . . . 8 1.2 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 1.3 Notational Conventions . . . . . . . . . . . ...
BX600 S3 Operating Manual 7 1 Preface The PRIMERGY BX600 S3 Blade Server System represents a highly compact, power-saving and scalable servers for integration in 19-inch rack systems. Figure 1: PRIMERGY BX600 S3 Basic Unit The PRIMERGY BX600 S3 basic unit occupies seven height units in the rack and ...
8 Operating Manual BX600 S3 Overview of the Documentation Preface © c ogn it a s . G e s e lls c h ft f ü r T e c h ni k -D o k u m e n ta ti on m b H 20 09 P fad : H :\ A p ri l\ P R IM E R GY _R eb rand in g \v o n W a lt er \b x 600 _s 3_ ba\ B X 6 0 0 S 3 _ e n \b la d e -u s. k0 1 Security func...
BX600 S3 Operating Manual 9 Preface Overview of the Documentation – “Returning used devices” manual (PDF file available on the ServerBooks DVD supplied) – “Helpdesk” (leaflet with worldwide helpdesk telephone numbers) – “BIOS Setup” (PDF file available on the ServerBooks DVD supplied) – „PRIMERGY BX...
10 Operating Manual BX600 S3 Features Preface © c ogn it a s . G e s e lls c h ft f ü r T e c h ni k -D o k u m e n ta ti on m b H 20 09 P fad : H :\ A p ri l\ P R IM E R GY _R eb rand in g \v o n W a lt er \b x 600 _s 3_ ba\ B X 6 0 0 S 3 _ e n \b la d e -u s. k0 1 1.2 Features The PRIMERGY BX600 S...
14 Operating Manual BX600 S3 Features Preface © c ogn it a s . G e s e lls c h ft f ü r T e c h ni k -D o k u m e n ta ti on m b H 20 09 P fad : H :\ A p ri l\ P R IM E R GY _R eb rand in g \v o n W a lt er \b x 600 _s 3_ ba\ B X 6 0 0 S 3 _ e n \b la d e -u s. k0 1 ● Watchdog timer for Automatic Se...
BX600 S3 Operating Manual 15 Preface Notational Conventions 1.3 Notational Conventions The following notational conventions are used in this manual: Italics indicate commands, menu items or software programs. “Quotation marks” indicate names of chapters and terms that should be emphasized. Ê Text wh...
16 Operating Manual BX600 S3 Technical Data Preface © c ogn it a s . G e s e lls c h ft f ü r T e c h ni k -D o k u m e n ta ti on m b H 20 09 P fad : H :\ A p ri l\ P R IM E R GY _R eb rand in g \v o n W a lt er \b x 600 _s 3_ ba\ B X 6 0 0 S 3 _ e n \b la d e -u s. k0 1 1.4 Technical Data Electric...
18 Operating Manual BX600 S3 Technical Data Preface © c ogn it a s . G e s e lls c h ft f ü r T e c h ni k -D o k u m e n ta ti on m b H 20 09 P fad : H :\ A p ri l\ P R IM E R GY _R eb rand in g \v o n W a lt er \b x 600 _s 3_ ba\ B X 6 0 0 S 3 _ e n \b la d e -u s. k0 1 Noise Level Sound power lev...
BX600 S3 Operating Manual 19 2 Overview: Installation Steps In this chapter you will find an overview of the steps necessary to install your BX600 S3 basic unit. Links guide you to sections where you can find more detailed information on the individual steps. Ê Before you begin, please read the chap...
BX600 S3 Operating Manual 21 3 Important Notes In this chapter you will find essential information on safety when working with your system. 3.1 Notes on Safety I You will also find the following safety instructions in the manual entitled “Safety“, which also includes additional notes on the guarante...
22 Operating Manual BX600 S3 Notes on Safety Important Notes © c ogn it a s . G e s e lls c h ft f ü r T e c h ni k -D o k u m e n ta ti on m b H 20 09 P fad : H :\ A p ri l\ P R IM E R GY _R eb rand in g \v o n W a lt er \b x 600 _s 3_ ba\ B X 6 0 0 S 3 _ e n \b la d e -u s. k0 3 Before Setting Up ...
BX600 S3 Operating Manual 23 Important Notes Notes on Safety V CAUTION! ● Due to the high power requirements of the BX600 S3 blade server, you must be careful when arranging the power cabling. Please notice the information that purpose in section “Notes on power cabling” on page 126 ). ● Make sure t...
24 Operating Manual BX600 S3 Notes on Safety Important Notes © c ogn it a s . G e s e lls c h ft f ü r T e c h ni k -D o k u m e n ta ti on m b H 20 09 P fad : H :\ A p ri l\ P R IM E R GY _R eb rand in g \v o n W a lt er \b x 600 _s 3_ ba\ B X 6 0 0 S 3 _ e n \b la d e -u s. k0 3 V CAUTION! ● Insta...
26 Operating Manual BX600 S3 CE Certificate Important Notes © c ogn it a s . G e s e lls c h ft f ü r T e c h ni k -D o k u m e n ta ti on m b H 20 09 P fad : H :\ A p ri l\ P R IM E R GY _R eb rand in g \v o n W a lt er \b x 600 _s 3_ ba\ B X 6 0 0 S 3 _ e n \b la d e -u s. k0 3 3.3 CE Certificate ...
BX600 S3 Operating Manual 27 Important Notes Transporting the Basic Unit specified by Fujitsu Technology Solutions. The correction of interferences caused by such unauthorized modification, substitution or attachment will be the responsibility of the user. The use of shielded I/O cables is required ...
28 Operating Manual BX600 S3 Notes on Installing in the Rack Important Notes © c ogn it a s . G e s e lls c h ft f ü r T e c h ni k -D o k u m e n ta ti on m b H 20 09 P fad : H :\ A p ri l\ P R IM E R GY _R eb rand in g \v o n W a lt er \b x 600 _s 3_ ba\ B X 6 0 0 S 3 _ e n \b la d e -u s. k0 3 V ...
BX600 S3 Operating Manual 29 Important Notes Environmental Protection 3.7 Environmental Protection Environmentally Friendly Product Design and Development This product has been designed in accordance with the Fujitsu Technology Solutions standards for ”environmentally friendly product design and dev...
30 Operating Manual BX600 S3 Environmental Protection Important Notes © c ogn it a s . G e s e lls c h ft f ü r T e c h ni k -D o k u m e n ta ti on m b H 20 09 P fad : H :\ A p ri l\ P R IM E R GY _R eb rand in g \v o n W a lt er \b x 600 _s 3_ ba\ B X 6 0 0 S 3 _ e n \b la d e -u s. k0 3 Returning...
BX600 S3 Operating Manual 31 Important Notes Environmental Protection Returning Batteries Batteries which are marked with one of the following symbols may not be disposed of together with household refuse according to the applicable EU directive. Figure 4: Symbols for batteries With batteries contai...
BX600 S3 Operating Manual 33 Installing the Hardware Installation Steps 4 Installing the Hardware V CAUTION! Please note the safety instructions in the chapter “Important Notes” on page 21 . Do not expose the PRIMERGY BX600 S3 basic unit to extreme environ-mental conditions (see section “Technical D...
34 Operating Manual BX600 S3 Unpacking the Basic Unit Installing the Hardware © c ogn it a s . G e s e lls c h ft f ü r T e c h ni k -D o k u m e n ta ti on m b H 20 09 P fad : H :\ A p ri l\ P R IM E R GY _R eb rand in g \v o n W a lt er \b x 600 _s 3_ ba\ B X 6 0 0 S 3 _ e n \b la d e -u s. k0 4 4...
BX600 S3 Operating Manual 35 Installing the Hardware Installing the System in the Rack 4.3 Installing the System in the Rack V CAUTION! ● For safety reasons, at least two people are required to install the PRIMERGY BX600 S3 basic unit because of its weight and size. ● Please observe the safety preca...
38 Operating Manual BX600 S3 Installing the System in the Rack Installing the Hardware © c ogn it a s . G e s e lls c h ft f ü r T e c h ni k -D o k u m e n ta ti on m b H 20 09 P fad : H :\ A p ri l\ P R IM E R GY _R eb rand in g \v o n W a lt er \b x 600 _s 3_ ba\ B X 6 0 0 S 3 _ e n \b la d e -u ...
40 Operating Manual BX600 S3 Installing the System in the Rack Installing the Hardware © c ogn it a s . G e s e lls c h ft f ü r T e c h ni k -D o k u m e n ta ti on m b H 20 09 P fad : H :\ A p ri l\ P R IM E R GY _R eb rand in g \v o n W a lt er \b x 600 _s 3_ ba\ B X 6 0 0 S 3 _ e n \b la d e -u ...
BX600 S3 Operating Manual 41 Installing the Hardware Connecting External Devices Ê Inser t the server blades into their slots (see section “Adding a Server Blade to the Basic Unit” on page 74 ). Return the power supply units and fan units to the basic unit (see section “Replacing a Power Supply Unit...
42 Operating Manual BX600 S3 Connecting External Devices Installing the Hardware © c ogn it a s . G e s e lls c h ft f ü r T e c h ni k -D o k u m e n ta ti on m b H 20 09 P fad : H :\ A p ri l\ P R IM E R GY _R eb rand in g \v o n W a lt er \b x 600 _s 3_ ba\ B X 6 0 0 S 3 _ e n \b la d e -u s. k0 ...
BX600 S3 Operating Manual 43 Installing the Hardware Connecting External Devices Figure 10: Special cable 4.4.1 Cable Routing The cables are routed directly on the rack suppor t uprights. PCI Cards with Cable at the Front If a PCI expansion module is installed in a server blade, you will have to con...
46 Operating Manual BX600 S3 Connecting the System to the Mains Installing the Hardware © c ogn it a s . G e s e lls c h ft f ü r T e c h ni k -D o k u m e n ta ti on m b H 20 09 P fad : H :\ A p ri l\ P R IM E R GY _R eb rand in g \v o n W a lt er \b x 600 _s 3_ ba\ B X 6 0 0 S 3 _ e n \b la d e -u...
50 Operating Manual BX600 S3 Operating and Indicator Elements Preparation for Use and Operation © c ogn it a s . G e s e lls c h ft f ü r T e c h ni k -D o k u m e n ta ti on m b H 20 09 P fad : H :\ A p ri l\ P R IM E R GY _R eb rand in g \v o n W a lt er \b x 600 _s 3_ ba\ B X 6 0 0 S 3 _ e n \b l...
BX600 S3 Operating Manual 51 Preparation for Use and Operation Operating and Indicator Elements 3 Front identify/Fault indicator (amber LED) Unlit: The system is normal and not highlighted.If power indicator LED lights green, basic unit is switched ON (5 V standby power present). Lights amber: This ...
52 Operating Manual BX600 S3 Operating and Indicator Elements Preparation for Use and Operation © c ogn it a s . G e s e lls c h ft f ü r T e c h ni k -D o k u m e n ta ti on m b H 20 09 P fad : H :\ A p ri l\ P R IM E R GY _R eb rand in g \v o n W a lt er \b x 600 _s 3_ ba\ B X 6 0 0 S 3 _ e n \b l...
BX600 S3 Operating Manual 53 Preparation for Use and Operation Switching the Blade Server ON/OFF 5.2 Switching the Basic Unit ON/OFF V CAUTION! ● Make sure that the PRIMERGY BX600 S3 basic unit is connected to the mains for at least one minute before pressing the power ON/OFF button to switch the sy...
BX600 S3 Operating Manual 55 Preparation for Use and Operation Management Blade Configuration 5.3 Management Blade Configuration The two redundant management blades provide functionality for remote control of the PRIMERGY BX600 S3 basic unit over the LAN (see chapter “Management Blade” on page 113 a...
56 Operating Manual BX600 S3 Management Blade Configuration Preparation for Use and Operation © c ogn it a s . G e s e lls c h ft f ü r T e c h ni k -D o k u m e n ta ti on m b H 20 09 P fad : H :\ A p ri l\ P R IM E R GY _R eb rand in g \v o n W a lt er \b x 600 _s 3_ ba\ B X 6 0 0 S 3 _ e n \b la ...
BX600 S3 Operating Manual 57 Preparation for Use and Operation Management Blade Configuration Ê Enter 1 to call up the Management Agent menu. The Management Agent menu looks like this: Figure 18: Management Agent menu. Ê Enter 1 to call up the Management Agent Information menu. The Management Agent ...
58 Operating Manual BX600 S3 Management Blade Configuration Preparation for Use and Operation © c ogn it a s . G e s e lls c h ft f ü r T e c h ni k -D o k u m e n ta ti on m b H 20 09 P fad : H :\ A p ri l\ P R IM E R GY _R eb rand in g \v o n W a lt er \b x 600 _s 3_ ba\ B X 6 0 0 S 3 _ e n \b la ...
BX600 S3 Operating Manual 59 Preparation for Use and Operation Management Blade Configuration I The management blade LAN controller only runs at 10 Mbit/sec. Duplex mode must be defined manually via the Agent NIC Duplex Mode (see figure 20 below). Figure 20: Agent NIC Duplex Mode menu Ê Enter 2 if t...
60 Operating Manual BX600 S3 Updating BX600 System Components Preparation for Use and Operation © c ogn it a s . G e s e lls c h ft f ü r T e c h ni k -D o k u m e n ta ti on m b H 20 09 P fad : H :\ A p ri l\ P R IM E R GY _R eb rand in g \v o n W a lt er \b x 600 _s 3_ ba\ B X 6 0 0 S 3 _ e n \b l...
62 Operating Manual BX600 S3 Updating BX600 System Components Preparation for Use and Operation © c ogn it a s . G e s e lls c h ft f ü r T e c h ni k -D o k u m e n ta ti on m b H 20 09 P fad : H :\ A p ri l\ P R IM E R GY _R eb rand in g \v o n W a lt er \b x 600 _s 3_ ba\ B X 6 0 0 S 3 _ e n \b l...
64 Operating Manual BX600 S3 Updating BX600 System Components Preparation for Use and Operation © c ogn it a s . G e s e lls c h ft f ü r T e c h ni k -D o k u m e n ta ti on m b H 20 09 P fad : H :\ A p ri l\ P R IM E R GY _R eb rand in g \v o n W a lt er \b x 600 _s 3_ ba\ B X 6 0 0 S 3 _ e n \b l...
BX600 S3 Operating Manual 65 Preparation for Use and Operation Updating BX600 System Components ⎜ Console Redirection Switch Blade page_3_2. ⎟ ⎜ -------------------------------------------------------------------------------- ⎟ ⎜ (1) Console Redirect Switch Blade_1 ⎟ ⎜ (2) Console Redirect Switch Bl...
BX600 S3 Operating Manual 67 Preparation for Use and Operation Updating BX600 System Components Figure 25: Transferring the new operation code image file Ê Click Transfer from Server . Ê Wait a few minutes until the update process is complete. Refresh the browser for viewing. Ê Select the new image ...
BX600 S3 Operating Manual 69 6 Property and Data Protection The lockable rack door protects the server against unauthorized access. To protect your system and data internally against unauthorized access, you can use the BIOS Setup security functions. Fur ther security options can also be set in the ...
BX600 S3 Operating Manual 71 7 Server Blades This chapter describes how to install and uninstall server blades and server blade dummy modules in the PRIMERGY BX600 S3 basic unit, and what you need to be aware of when doing this. The information necessary for installing and operating the various serv...
BX600 S3 Operating Manual 73 Server Blades Fitting rules 7.1 Fitting rules On the front of the PRIMERGY BX600 S3 basic unit are ten slots for server blades (numbered 1 - 10 from left to right). Figure 29: BX600 S3 basic unit with ten 2-way server blades All ten slots are connected to the infrastruct...
74 Operating Manual BX600 S3 Adding a Server Blade to the System Server Blades © c ogn it a s . G e s e lls c h ft f ü r T e c h ni k -D o k u m e n ta ti on m b H 20 09 P fad : H :\ A p ri l\ P R IM E R GY _R eb rand in g \v o n W a lt er \b x 600 _s 3_ ba\ B X 6 0 0 S 3 _ e n \b la d e -u s. k0 7 ...
BX600 S3 Operating Manual 75 Server Blades Adding a Server Blade to the System Figure 30: Removing a server blade dummy module Ê Release the locking mechanism of the ejecting handles by pressing the touch points on the inside of both handles (1) simultaneously. The ejecting handles of the dummy modu...
76 Operating Manual BX600 S3 Adding a Server Blade to the System Server Blades © c ogn it a s . G e s e lls c h ft f ü r T e c h ni k -D o k u m e n ta ti on m b H 20 09 P fad : H :\ A p ri l\ P R IM E R GY _R eb rand in g \v o n W a lt er \b x 600 _s 3_ ba\ B X 6 0 0 S 3 _ e n \b la d e -u s. k0 7 ...
78 Operating Manual BX600 S3 Adding a Server Blade to the System Server Blades © c ogn it a s . G e s e lls c h ft f ü r T e c h ni k -D o k u m e n ta ti on m b H 20 09 P fad : H :\ A p ri l\ P R IM E R GY _R eb rand in g \v o n W a lt er \b x 600 _s 3_ ba\ B X 6 0 0 S 3 _ e n \b la d e -u s. k0 7 ...
BX600 S3 Operating Manual 79 8 Ethernet LAN I/O Blades This chapter outlines the main features of the Ethernet LAN I/O blades available with the PRIMERGY BX600 S3 blade server. For each switch blade it describes the indicator and connection elements of the control and connection panel. This chapter ...
86 Operating Manual BX600 S3 Cisco Catalyst Blade Switch 3040 Ethernet I/O Blades © c ogn it a s . G e s e lls c h ft f ü r T e c h ni k -D o k u m e n ta ti on m b H 20 09 P fad : H :\ A p ri l\ P R IM E R GY _R eb rand in g \v o n W a lt er \b x 600 _s 3_ ba\ B X 6 0 0 S 3 _ e n \b la d e -u s. k0...
BX600 S3 Operating Manual 91 Ethernet I/O Blades Port Assignment 8.9 Port Assignment of the LAN Switch Blades For each of the ten server blade slots, connections to a maximum of 6 por ts of the onboard LAN controller and to 2 ports of the optional Gigabit Ethernet daughter card are available in the ...
92 Operating Manual BX600 S3 Port Assignment Ethernet I/O Blades © c ogn it a s . G e s e lls c h ft f ü r T e c h ni k -D o k u m e n ta ti on m b H 20 09 P fad : H :\ A p ri l\ P R IM E R GY _R eb rand in g \v o n W a lt er \b x 600 _s 3_ ba\ B X 6 0 0 S 3 _ e n \b la d e -u s. k0 8 The configurat...
94 Operating Manual BX600 S3 Port Assignment Ethernet I/O Blades © c ogn it a s . G e s e lls c h ft f ü r T e c h ni k -D o k u m e n ta ti on m b H 20 09 P fad : H :\ A p ri l\ P R IM E R GY _R eb rand in g \v o n W a lt er \b x 600 _s 3_ ba\ B X 6 0 0 S 3 _ e n \b la d e -u s. k0 8 Configuration ...
96 Operating Manual BX600 S3 Installing an I/O Blade Ethernet I/O Blades © c ogn it a s . G e s e lls c h ft f ü r T e c h ni k -D o k u m e n ta ti on m b H 20 09 P fad : H :\ A p ri l\ P R IM E R GY _R eb rand in g \v o n W a lt er \b x 600 _s 3_ ba\ B X 6 0 0 S 3 _ e n \b la d e -u s. k0 8 8.10 I...
BX600 S3 Operating Manual 97 Ethernet I/O Blades Installing an I/O Blade Figure 46: Disengaging the dummy module Ê Swing the handle (a) in the direction of the arrow (2) until the locking mechanism of the dummy module disengages. Figure 47: Removing the dummy module Ê Remove the dummy module from th...
98 Operating Manual BX600 S3 Installing an I/O Blade Ethernet I/O Blades © c ogn it a s . G e s e lls c h ft f ü r T e c h ni k -D o k u m e n ta ti on m b H 20 09 P fad : H :\ A p ri l\ P R IM E R GY _R eb rand in g \v o n W a lt er \b x 600 _s 3_ ba\ B X 6 0 0 S 3 _ e n \b la d e -u s. k0 8 Insert...
BX600 S3 Operating Manual 99 Ethernet I/O Blades Installing an I/O Blade Figure 49: Inserting the I/O blade (a = green touch point) Ê Push (1) the I/O blade as far as possible into the desired slot (here slot 2). Ê Swing up (2) the eject handle (a) of the I/O blade until the locking mechanism of the...
BX600 S3 Operating Manual 101 9 Fibre Channel I/O Blades This chapter describes the Fibre Channel I/O blades that are available for the PRIMERGY BX600 S3 blade server. It outlines the most important features and the external ports of the individual I/O blades, the internal por t assignment to the se...
BX600 S3 Operating Manual 103 Fibre Channel I/O Blades 4/4 Gbit FC Switch Blade SW4016 4D Control and Connection Panel Figure 51: Control and connection panel of the 4/4 Gbit Fibre Channel Switch Blade 1 External FC connection (6x)socket for LWL or SWL FC SFP module (see section “Fibre Channel SFP M...
BX600 S3 Operating Manual 105 Fibre Channel I/O Blades 2 Gbit FC Pass-Thru Blade 9.3 2 Gbit Fibre Channel Pass-Thru Blade The 2 Gbit Fibre Channel pass-thru blade provides 10 por ts for the bypass connection between server blade FC daughter boards and optical transceivers for serial FC I/O and gener...
106 Operating Manual BX600 S3 4 Gbit FC Pass-Thru Blade Fibre Channel I/O Blades © c ogn it a s . G e s e lls c h ft f ü r T e c h ni k -D o k u m e n ta ti on m b H 20 09 P fad : H :\ A p ri l\ P R IM E R GY _R eb rand in g \v o n W a lt er \b x 600 _s 3_ ba\ B X 6 0 0 S 3 _ e n \b la d e -u s. k0 ...
BX600 S3 Operating Manual 107 Fibre Channel I/O Blades Fibre Channel SFP Module 9.5 Fibre Channel SFP Module A Fibre Channel SFP module is required to connect an FC pass-thru blade por t to a Fibre Channel cable. If no cable is plugged in, the SFP module slots must be fitted with a safety plug as sh...
108 Operating Manual BX600 S3 Fibre Channel SFP Module Fibre Channel I/O Blades © c ogn it a s . G e s e lls c h ft f ü r T e c h ni k -D o k u m e n ta ti on m b H 20 09 P fad : H :\ A p ri l\ P R IM E R GY _R eb rand in g \v o n W a lt er \b x 600 _s 3_ ba\ B X 6 0 0 S 3 _ e n \b la d e -u s. k0 9...
BX600 S3 Operating Manual 109 Fibre Channel I/O Blades Port Assignment 9.6 Port Assignment Slots NET3 and NET4 on the back of the basic unit can be fitted with Fibre Channel I/O blades. The Fibre Channel I/O blade in the NET3 slot is connected to por t A of the installed Fibre Channel daughter cards...
110 Operating Manual BX600 S3 Port Assignment Fibre Channel I/O Blades © c ogn it a s . G e s e lls c h ft f ü r T e c h ni k -D o k u m e n ta ti on m b H 20 09 P fad : H :\ A p ri l\ P R IM E R GY _R eb rand in g \v o n W a lt er \b x 600 _s 3_ ba\ B X 6 0 0 S 3 _ e n \b la d e -u s. k0 9 The conf...
112 Operating Manual BX600 S3 FC I/O blade installation Fibre Channel I/O Blades © c ogn it a s . G e s e lls c h ft f ü r T e c h ni k -D o k u m e n ta ti on m b H 20 09 P fad : H :\ A p ri l\ P R IM E R GY _R eb rand in g \v o n W a lt er \b x 600 _s 3_ ba\ B X 6 0 0 S 3 _ e n \b la d e -u s. k0 ...
BX600 S3 Operating Manual 113 10 Management Blade The PRIMERGY BX600 S3 basic unit accommodates two hot-swappable, redundant management blades with an integrated management solution for complete remote administration of the system. I The management blades provide convenient user interfaces: A web in...
114 Operating Manual BX600 S3 Control and Connection Panel Management Blade © c ogn it a s . G e s e lls c h ft f ü r T e c h ni k -D o k u m e n ta ti on m b H 20 09 P fad : H :\ A p ri l\ P R IM E R GY _R eb rand in g \v o n W a lt er \b x 600 _s 3_ ba\ B X 6 0 0 S 3 _ e n \b la d e -u s. k1 0 10....
116 Operating Manual BX600 S3 Exchanging a Management Blade Management Blade © c ogn it a s . G e s e lls c h ft f ü r T e c h ni k -D o k u m e n ta ti on m b H 20 09 P fad : H :\ A p ri l\ P R IM E R GY _R eb rand in g \v o n W a lt er \b x 600 _s 3_ ba\ B X 6 0 0 S 3 _ e n \b la d e -u s. k1 0 10...
118 Operating Manual BX600 S3 Exchanging a Management Blade Management Blade © c ogn it a s . G e s e lls c h ft f ü r T e c h ni k -D o k u m e n ta ti on m b H 20 09 P fad : H :\ A p ri l\ P R IM E R GY _R eb rand in g \v o n W a lt er \b x 600 _s 3_ ba\ B X 6 0 0 S 3 _ e n \b la d e -u s. k1 0 Fi...
BX600 S3 Operating Manual 119 11 KVM Blade For administering the server blades, the PRIMERGY BX600 S3 basic unit offers a KVM blade, which allows the individual server blades to be connected to a console. Figure 65: Position of the KVM blade The following models are available: – KVM blade (standard ...
120 Operating Manual BX600 S3 KVM Blade (Standard Version) KVM Blade © c ogn it a s . G e s e lls c h ft f ü r T e c h ni k -D o k u m e n ta ti on m b H 20 09 P fad : H :\ A p ri l\ P R IM E R GY _R eb rand in g \v o n W a lt er \b x 600 _s 3_ ba\ B X 6 0 0 S 3 _ e n \b la d e -u s. k1 1 Control Pa...
BX600 S3 Operating Manual 121 KVM Blade Adv. KVM Blade 11.2 Adv. KVM Blade The adv. KVM blade offers the same functionality as the standard version of the KVM blade plus a LAN port for connecting a Web-based console with the following features: – Console emulation in graphics mode – Makes the CD-ROM...
BX600 S3 Operating Manual 123 KVM Blade Digital KVM Blade 11.3 Digital KVM Blade The digital KVM blade offers the same functionality as the standard version of the KVM blade plus a LAN port for connecting a Web-based console with the following features: – Console emulation in graphics mode – Makes t...
BX600 S3 Operating Manual 125 12 Power Supply Concept In the basic configuration, the PRIMERGY BX600 S3 basic unit contains two hot swap power supply units (PSU1 and PSU2 in figure 69 ). The power supply units adapt automatically to any voltage within the range 200 V - 240 V. Figure 69: PRIMERGY BX6...
126 Operating Manual BX600 S3 Notes on power cabling Power Supply Concept © c ogn it a s . G e s e lls c h ft f ü r T e c h ni k -D o k u m e n ta ti on m b H 20 09 P fad : H :\ A p ri l\ P R IM E R GY _R eb rand in g \v o n W a lt er \b x 600 _s 3_ ba\ B X 6 0 0 S 3 _ e n \b la d e -u s. k1 2 Phase...
128 Operating Manual BX600 S3 Notes on power cabling Power Supply Concept © c ogn it a s . G e s e lls c h ft f ü r T e c h ni k -D o k u m e n ta ti on m b H 20 09 P fad : H :\ A p ri l\ P R IM E R GY _R eb rand in g \v o n W a lt er \b x 600 _s 3_ ba\ B X 6 0 0 S 3 _ e n \b la d e -u s. k1 2 Singl...
130 Operating Manual BX600 S3 Notes on power cabling Power Supply Concept © c ogn it a s . G e s e lls c h ft f ü r T e c h ni k -D o k u m e n ta ti on m b H 20 09 P fad : H :\ A p ri l\ P R IM E R GY _R eb rand in g \v o n W a lt er \b x 600 _s 3_ ba\ B X 6 0 0 S 3 _ e n \b la d e -u s. k1 2 Two b...
BX600 S3 Operating Manual 131 Power Supply Concept Power Supply Units 12.2 Power Supply Units The power supply units (PSU) are directly accessible at the rear of the system ( figure 69 on page 125 ): The power supply unit can communicate with the system service processor via an internal management i...
132 Operating Manual BX600 S3 Power Supply Units Power Supply Concept © c ogn it a s . G e s e lls c h ft f ü r T e c h ni k -D o k u m e n ta ti on m b H 20 09 P fad : H :\ A p ri l\ P R IM E R GY _R eb rand in g \v o n W a lt er \b x 600 _s 3_ ba\ B X 6 0 0 S 3 _ e n \b la d e -u s. k1 2 Figure 76...
BX600 S3 Operating Manual 133 Power Supply Concept Power Supply Units 12.2.1 Replacing a Power Supply Unit If a power unit fails, the front orange ID LED blinks in the system unit operator panel. The defective power unit can be replaced while the basic unit is still running. V CAUTION Do not, under ...
136 Operating Manual BX600 S3 Power Supply Units Power Supply Concept © c ogn it a s . G e s e lls c h ft f ü r T e c h ni k -D o k u m e n ta ti on m b H 20 09 P fad : H :\ A p ri l\ P R IM E R GY _R eb rand in g \v o n W a lt er \b x 600 _s 3_ ba\ B X 6 0 0 S 3 _ e n \b la d e -u s. k1 2 Figure 79...
BX600 S3 Operating Manual 139 13 Ventilation Concept The basic unit is kept cool by two fan units (two fans each), and the fans in the power supply units (three fans in each PSU) and/or the fans in the PSU dummy unit(s) (two fans in each dummy). The fan units are accessible from the rear of the syst...
140 Operating Manual BX600 S3 The Fan Unit Ventilation Concept © c ogn it a s . G e s e lls c h ft f ü r T e c h ni k -D o k u m e n ta ti on m b H 20 09 P fad : H :\ A p ri l\ P R IM E R GY _R eb rand in g \v o n W a lt er \b x 600 _s 3_ ba\ B X 6 0 0 S 3 _ e n \b la d e -u s. k1 3 13.1 The Fan Uni...
BX600 S3 Operating Manual 141 Ventilation Concept The Fan Unit 13.1.1 Replacing the Fan Unit V CAUTION! If a system error has occurred and the front identify/fault LED is blinking, the error must be resolved before any additional components are added or removed. Make sure that all necessary power su...
142 Operating Manual BX600 S3 The Fan Unit Ventilation Concept © c ogn it a s . G e s e lls c h ft f ü r T e c h ni k -D o k u m e n ta ti on m b H 20 09 P fad : H :\ A p ri l\ P R IM E R GY _R eb rand in g \v o n W a lt er \b x 600 _s 3_ ba\ B X 6 0 0 S 3 _ e n \b la d e -u s. k1 3 Figure 84: Remov...
BX600 S3 Operating Manual 143 Ventilation Concept The Fan Unit 13.1.2 Replacing a Fan in the Unit Figure 85: Disengaging the fan unit (a = green touch point) Ê Pull (1) the locking handle (green) to disengage the fan. Ê Remove the fan from the unit (2). To mount a fan, follow these instructions in t...
BX600 S3 Operating Manual 145 14 Troubleshooting and Tips V CAUTION! Please note the safety instructions in the chapter “Important Notes” on page 21 . If a fault occurs, try to correct it as described – in this chapter – in the chapters for the components installed – in the documentation for the con...
BX600 S3 Operating Manual 147 Troubleshooting and Tips 14.3 System Switches Itself OFF Server management has detected an error Ê In the ServerView program, check the error list or the error log file with the SCU utility and try to eliminate the error (see manual “ PRIMERGY BX Blade Server Systems: R...
148 Operating Manual BX600 S3 Troubleshooting and Tips © c ogn it a s . G e s e lls c h ft f ü r T e c h ni k -D o k u m e n ta ti on m b H 20 09 P fad : H :\ A p ri l\ P R IM E R GY _R eb rand in g \v o n W a lt er \b x 600 _s 3_ ba\ B X 6 0 0 S 3 _ e n \b la d e -u s. k1 4 14.5 Flickering Stripes ...
BX600 S3 Operating Manual 149 Troubleshooting and Tips 14.8 Floppy Disk Cannot Be Read/Written Ê Check whether the write protection of the floppy disk is activated. Ê Check the entry for the floppy disk drive in the BIOS Setup for the correspon-ding server blade. Ê Check the BIOS Setup for the corre...
150 Operating Manual BX600 S3 Troubleshooting and Tips © c ogn it a s . G e s e lls c h ft f ü r T e c h ni k -D o k u m e n ta ti on m b H 20 09 P fad : H :\ A p ri l\ P R IM E R GY _R eb rand in g \v o n W a lt er \b x 600 _s 3_ ba\ B X 6 0 0 S 3 _ e n \b la d e -u s. k1 4 Added drive is identifie...
BX600 S3 Operating Manual 151 Abbreviations ASR&R Automatic Server Reconfiguration and Restar t ATA Advanced Technology Attachment BIOS Basic Input-Output System BMC Baseboard Management Controller CD Compact Disk CE Communauté Européenne COM Communication CPU Central Processing Unit DBMS Databa...
BX600 S3 Operating Manual 157 Related Publications PRIMERGY manuals are available in PDF format on the ServerBooks DVD. The ServerBooks DVD is par t of the PRIMERGY ServerView Suite, delivered with each server system. The PDF files for the manuals can also be downloaded free of charge from the Inter...
158 Operating Manual BX600 S3 Related publications © c ogn it a s . G e s e lls c h ft f ü r T e c h ni k -D o k u m e n ta ti o n m b H 200 9 P fad : H :\ A pr il\ P R IM E R G Y _R ebr and ing\ v o n Wal ter \b x 6 00 _s 3_b a\ B X 600 S 3_e n \b la d e -u s .lit [13] PRIMERGY BX630 Scalable Serve...
BX600 S3 Operating Manual 161 Index 10 GBit CX4 connector 83 10 GBit XFP connector 82 Aadding server blade 74 Adv. KVM blade 121 approvals product safety 17 ASR&R 13 availability 13 BBIOS security functions 69 BIOS update 14 Ccables connecting 45 disconnecting 45 carrier rail 39 CE label 16 , 26...
Fujitsu Manuals
-
Fujitsu P42VCA12
Manual
- Fujitsu S500M Manual
-
Fujitsu C1410
Manual
- Fujitsu FI-6140Z Manual
-
Fujitsu P50XHA40U
Manual
-
Fujitsu D1931
Manual
-
Fujitsu PDS5003W
Manual
-
Fujitsu M4099D
Manual
-
Fujitsu P63XHA40U
Manual
-
Fujitsu B6220
Manual
-
Fujitsu M3093DE
Manual
-
Fujitsu ETERNUS DX8000 series
Manual
-
Fujitsu FTP-641MCL352
Manual
-
Fujitsu YV2.4X2.5A-2
Manual
-
Fujitsu FS-1008MU
Manual
- Fujitsu T731 Manual
-
Fujitsu FTP-627MCL113
Manual
-
Fujitsu ETERNUS4000
Manual
-
Fujitsu FMWCC42
Manual
-
Fujitsu FTP-607 Series
Manual