En-1 CONTENTS ● Do not attempt to install this air conditioner by yourself. ● This unit contains no user-serviceable parts. Always consult authorized service per-sonnel for repairs. ● When moving, consult authorized service personnel for disconnection and installa-tion of the unit. ● Do not become o...
Page 3 - Q R; NAME OF PARTS; Electrical Breaker; Fig. 4 Remote Controller
En-2 ° F NON STOP AMPM CLOCK AMPM TIMER NEXT DAY DAY OFFONTIMERWEEKLY AUTO OFF ON OFF ON DAY OFF DEFROST TEST 2 1 AUTO HEAT FAN COOL TIMER MODE SET ZONE START/STOP CLOCK ADJUST SET TIME TEMP./DAY FAN CONTROL MASTER CONTROL DAY OFF ENERGY SAVE ° F NON STOP AM CLOCK AUTO F E D C 0 A 7 9 B 8 6 I H L G ...
Page 4 - Set the Current Time and Day; PREPARATION; To Select Mode Operation; Thermostat setting range:; OPERATION
En-3 TIMER MODE SET ZONE START/STOP CLOCK ADJUST SET TIME TEMP./DAY FAN CONTROL MASTER CONTROL DAY OFF ENERGY SAVE ° F NON STOP AM CLOCK AUTO Example: When set to AUTO Example: When set to 84 °F TIMER MODE SET ZONE START/STOP CLOCK ADJUST SET TIME TEMP./DAY FAN CONTROL MASTER CONTROL DAY OFF ENERGY ...
Page 5 - To Set the Fan Speed; Fan; To Stop Operation; About Mode Operation
En-4 : HIGH : MED : LOW TIMER MODE SET ZONE START/STOP CLOCK ADJUST SET TIME TEMP./DAY FAN CONTROL MASTER CONTROL DAY OFF ENERGY SAVE ° F NON STOP AM CLOCK AUTO To Set the Fan Speed Press the FAN CONTROL button to select the fan speed. AUTO HIGH MED LOW When set to AUTO:* Heating : Fan operates so a...
Page 6 - Press the SET TIME button and set the timer time.; To confirm settings
En-5 TIMER MODE SET ZONE START/STOP CLOCK ADJUST SET TIME TEMP./DAY FAN CONTROL MASTER CONTROL DAY OFF ENERGY SAVE ° F AM CLOCK PM TIMER OFFTIMER OFF COOL TIMER MODE SET ZONE START/STOP CLOCK ADJUST SET TIME TEMP./DAY FAN CONTROL MASTER CONTROL DAY OFF ENERGY SAVE ° F AM CLOCK AM TIMER OFFTIMER OFF ...
Page 7 - Weekly Timer Features; Set different operating times for each day of the week.; Setting Up the Weekly Timer Operation
En-6 TIMER MODE SET ZONE START/STOP CLOCK ADJUST SET TIME TEMP./DAY FAN CONTROL MASTER CONTROL DAY OFF ENERGY SAVE AM TIMER DAY WEEKLY ON OFF 1 4 5 TIMER MODE SET ZONE START/STOP CLOCK ADJUST SET TIME TEMP./DAY FAN CONTROL MASTER CONTROL DAY OFF ENERGY SAVE TIMER DAY WEEKLY ON OFF 1 COOL 1 2 3 TIMER...
Page 8 - Press the SET button.
En-7 PM PM TIMER NEXT DAY DAY WEEKLY ON OFF 2 TIMER MODE SET TIME TEMP./DAY FAN CONTROL AM CLOCK TIMER MODE SET ZONE START/STOP CLOCK ADJUST SET TIME TEMP./DAY FAN CONTROL MASTER CONTROL DAY OFF ENERGY SAVE AM PM TIMER DAY WEEKLY ON OFF 1 6 7 NOTES: (1) If no time values are flashing, the clock disp...
Page 9 - To Stop Weekly Timer Operation
En-8 PM PM TIMER DAY WEEKLY ON OFF 2 TIMER DAY WEEKLY ON OFF 1 TIMER MODE SET ZONE START/STOP CLOCK ADJUST SET TIME TEMP./DAY FAN CONTROL MASTER CONTROL DAY OFF ENERGY SAVE PM TIMER DAY WEEKLY ON OFF 1 2 3 TIMER MODE SET ZONE START/STOP CLOCK ADJUST SET TIME TEMP./DAY FAN CONTROL MASTER CONTROL DAY ...
Page 10 - To Change Selected Time Settings
En-9 DAY WEEKLY AUTO ON OFF TIMER MODE SET ZONE START/STOP CLOCK ADJUST SET TIME TEMP./DAY FAN CONTROL MASTER CONTROL 2 1 AUTO DEFROST TEST DAY OFF ENERGY SAVE PM PM TIMER 4 3 TIMER MODE SET ZONE START/STOP CLOCK ADJUST SET TIME TEMP./DAY FAN CONTROL MASTER CONTROL DAY OFF ENERGY SAVE PM PM TIMER DA...
Page 11 - About the DAY OFF; Using the DAY OFF Setting; Precautions during setup
En-10 TIMER MODE SET TIME TEMP./DAY FAN CONTROL MASTER ° F AM CLOCK TIMER WEEKLY DAY OFF COOL TIMER MODE SET ZONE START/STOP CLOCK ADJUST SET TIME TEMP./DAY FAN CONTROL MASTER CONTROL DAY OFF ENERGY SAVE PM PM TIMER DAY WEEKLY ON OFF DAY OFF 1 COOL 2 About the DAY OFF ● Use the DAY OFF setting to sw...
Page 12 - ENERGY SAVE OPERATION; To Use the ENERGY SAVE; To Stop the ENERGY SAVE; About the ENERGY SAVE; When Cooling
En-11 TIMER MODE SET ZONE START/STOP CLOCK ADJUST SET TIME TEMP./DAY FAN CONTROL MASTER CONTROL DAY OFF ENERGY SAVE ° F NON STOP AM CLOCK AUTO ENERGY SAVE OPERATION To Use the ENERGY SAVE Press the ENERGY SAVE button. The unit will run in the ENERGY SAVE mode. The ENERGY SAVE lamp (green) will light...
Page 13 - ADJUSTING THE DIRECTION OF AIR CIRCULATION; About Swing Operation; Air flow direction set; SWING OPERATION
En-12 Vertical Air Flow Direction Adjustment Press the AIR FLOW DIRECTION SET button. Each time the button is pressed, the air flow direction range will change as fol-lows: 1 2 3 4 The remote controller’s display does not change. ● Use the air flow direction adjustments within the ranges shown above...
Page 14 - CLEANING AND CARE; Cleaning the Air Filter
En-13 ● Before cleaning the unit, be sure to stop the unit and disconnect the power supply. ● Turn off the electrical breaker. ● A fan operates at high speed inside the unit, and personal injury could result. CLEANING AND CARE CAUTION! Cleaning the Air Filter 1. Push the intake grille pushbuttons (t...
Page 15 - STOP button to turn it off.; ERRORS AND SELF DIAGNOSIS
En-14 TIMER MODE SET ZONE START/STOP CLOCK ADJUST SET TIME TEMP./DAY FAN CONTROL MASTER CONTROL DAY OFF ENERGY SAVE Error Code If there is a problem with the air conditioner, it will stop run-ning and “E: EE” will be displayed instead of the clock. (1) If the operation lamp is on then press the STAR...
Page 16 - OPERATION DETAILS; Temperature and Humidity Range; * Heating Performance; AUTO Restart; In Event of Power Interruption; COOLING MODEL
En-15 OPERATION DETAILS Temperature and Humidity Range Operation and Performance * Heating Performance ● This air conditioner uses a heat pump which absorbs heatfrom outside air and brings it indoors. As a result, its heat-ing performance is reduced as the temperature of out-side air drops. If you f...
Page 17 - SYSTEM OPERATION; ; To Use the ZONE CONTROL; To Stop the ZONE CONTROL
En-16 TIMER MODE SET ZONE START/STOP CLOCK ADJUST SET TIME TEMP./DAY FAN CONTROL MASTER CONTROL DAY OFF ENERGY SAVE ° F NON STOP AM CLOCK AUTO SYSTEM OPERATION <Control Several Units with just one Remote Controller> One remote controller can control up to 16 air conditioners.All the air condit...
Page 18 - TROUBLESHOOTING; Symptom; Problem
En-17 TROUBLESHOOTING Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). In the event of a malfunction (burning smell, etc.), immediately stop operation, turn off the elec-trical breaker, and consult authorized service personnel.Merely turning off th...