Page 2 - UNVENTED PROPANE/LP GAS LOG HEATER; DANGER: Carbon monoxide; WARNINGS; WARNING: Any change to this; Carbon Monoxide Poisoning:; WARNING: Do not allow fans
2 105192 UNVENTED PROPANE/LP GAS LOG HEATER SAFETYINFORMATION DANGER: Carbon monoxide poisoning may lead to death! WARNING ICON G 001 WARNINGS IMPORTANT: Read this owner’smanual carefully and completelybefore trying to assemble, oper-ate, or service this heater. Im-proper use of this heater cancause...
Page 3 - OWNER’S MANUAL; LOCAL CODES; OPERATION; UNPACKING; Figure 1 - Heat MajicTM Log Set; CAUTION: Do not remove the; Continued
3 105192 OWNER’S MANUAL LOCAL CODES Install and use heater with care. Follow alllocal codes. In the absence of local codes, usethe latest edition of The National Fuel GasCode ANSI Z223.1/NFPA 54*. *Available from: American National Standards Institute, Inc. 1430 Broadway New York, NY 10018 National ...
Page 4 - Unusually Tight Construction; per kw) of the aggregate input
4 105192 UNVENTED PROPANE/LP GAS LOG HEATER AIR FORCOMBUSTION ANDVENTILATION PROVIDING ADEQUATEVENTILATION The following are excerpts from Na-tional Fuel Gas Code , ANSI Z223.1/NFPA 54, Section 5.3, Air for Combus-tion and Ventilation. All spaces in homes fall into one of the threefollowing ventilat...
Page 5 - DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION; Determining if You Have a Confined or Unconfined Space
5 105192 OWNER’S MANUAL AIR FOR COMBUSTIONAND VENTILATION Continued Continued DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION Determining if You Have a Confined or Unconfined Space Use this work sheet to determine if you have a confined or unconfined space. Space: Includes the room in which you will ...
Page 6 - Ventilation Air From Outdoors; Do not provide openings for; Figure 3 - Ventilation Air from Outdoors
6 105192 UNVENTED PROPANE/LP GAS LOG HEATER AIR FORCOMBUSTION ANDVENTILATION Continued VENTILATION AIR Ventilation Air From InsideBuilding This fresh air would come from an adjoiningunconfined space. When ventilating to anadjoining unconfined space, you must pro-vide two permanent openings: one with...
Page 7 - LOG SIZING REQUIREMENTS; INSTALLATION; CHECK GAS TYPE; A. Clearances from the side of the fireplace
7 105192 OWNER’S MANUAL LOG SIZING REQUIREMENTS Log Minimum Firebox Size Height Depth Front Rear* Width Width 18" 17" 14" 24" 20" 24" 17" 14" 28" 21" 30" 17" 14" 34" 24" INSTALLATION ANDCLEARANCES (Vent-FreeOperation Only) WARNING: Maintain...
Page 8 - If using a mantel, proceed to If Using
8 105192 UNVENTED PROPANE/LP GAS LOG HEATER INSTALLATION Continued Figure 5 - Heat Resistant Material (Slate,Marble, Tile, etc.) Above Fireplace Heat ResistantMaterial (A) Minimum NoncombustibleMaterial Clearances If Not Using Mantel Note: If using a mantel, proceed to If Using a Mantel. If not usin...
Page 9 - Figure 7 - Minimum Mantel Clearances When Using Hood; Figure 6 - Minimum Mantel Clearances Without Using Hood; MANTEL CLEARANCES; flue damper open; FLOOR CLEARANCES; A. If installing appliance on the floor level,
9 105192 OWNER’S MANUAL Figure 7 - Minimum Mantel Clearances When Using Hood Minimum Non-Combustible Material 8"Min. 12" 15" 18" All minimum distances arein inches 20" 2 1 /2 " 6" 8" 10" 12" Distances to Underside ofMantel Hood(HDABK, HDABR) Top of FireplaceOp...
Page 10 - You prefer vented operation; Figure 10 - Attaching Damper Clamp; Make sure the heater burner; Masonry Fireplace
10 105192 UNVENTED PROPANE/LP GAS LOG HEATER INSTALLATION ContinuedINSTALLING DAMPERCLAMP ACCESSORY FORVENTED OPERATION Note: When used as a vented heater, appli- ance must be installed only in a solid-fuelburning fireplace with a working flue andconstructed of non combustible material. You may use ...
Page 11 - Figure 12 - Attaching Base Assembly to Fireplace Floor; Figure 11 - Attaching Flexible Gas Hose to Heater Gas Regulator; Installation Items Needed
11 105192 OWNER’S MANUAL Masonry Screw Figure 12 - Attaching Base Assembly to Fireplace Floor Bracket withScrew Holes INSTALLATION Continued Heater GasRegulator Flexible Gas Hose(if allowed by localcodes) Figure 11 - Attaching Flexible Gas Hose to Heater Gas Regulator Fitting Continued Installation ...
Page 12 - Figure 14 - Gas Connection; CAUTION: Avoid damage to; WARNING: Never connect
12 105192 UNVENTED PROPANE/LP GAS LOG HEATER INSTALLATION Continued Tee Joint PipeNipple Cap 3" Minimum Sediment Trap GasRegulator From ExternalRegulator(11" W.C.** to14" W.C.Pressure) CSA Design-CertifiedEquipment Shutoff ValveWith 1/8" NPT Tap Approved FlexibleGas Hose (if allowedb...
Page 13 - Figure 15 - Equipment Shutoff Valve; Figure 16 - Checking Gas Joints; Correct all leaks at once.; WARNING: Never use an open
13 105192 OWNER’S MANUAL ON POSITION OFF POSITION INSTALLATION Continued Figure 15 - Equipment Shutoff Valve Open Closed EquipmentShutoffValve Figure 16 - Checking Gas Joints Control ValveLocation Propane/LPSupply Tank EquipmentShutoffValve Pressure Testing Gas SupplyPiping System Test Pressures In ...
Page 14 - WARNING: Failure to position; INSTALLING LOGS; Make sure log does not; CAUTION: After installation
14 105192 UNVENTED PROPANE/LP GAS LOG HEATER INSTALLATION Continued WARNING: Failure to position the parts in accordance with thesediagrams or failure to use onlyparts specifically approved withthis heater may result in propertydamage or personal injury. INSTALLING LOGS It is very important to insta...
Page 15 - FOR YOUR SAFETY; Figure 19 - Control Knob and Ignitor Button Location; LIGHTING; • If fireplace has glass doors,
15 105192 OWNER’S MANUAL 1. STOP! Read the safety information,column 1. 2. Make sure equipment shutoff valveis fully open. 3. Press in and turn control knob clock- wise Clockwise to the OFF position. Figure 20 - Pilot OPERATINGHEATER FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not fol- l...
Page 16 - Appearance of pilot; Figure 21 - Correct Pilot Flame Pattern; Figure 22 - Incorrect Pilot Flame Pattern; Shutting Off Heater; WARNING: Do not operate
16 105192 UNVENTED PROPANE/LP GAS LOG HEATER INSPECTINGBURNERS Check pilot flame pattern and burner flamepatterns often. PILOT FLAME PATTERN Figure 21 shows a correct pilot flame pat-tern. Figure 22 shows an incorrect pilotflame pattern. ( Note: Appearance of pilot assembly may vary by model.) The i...
Page 17 - TROUBLESHOOTING; POSSIBLE CAUSE; All troubleshooting items are listed in
17 105192 OWNER’S MANUAL TROUBLESHOOTING WARNING: Turn off and un- plug heater and let cool beforeservicing. Only a qualified ser-vice person should service andrepair heater. CAUTION: Never use a wire, needle, or similar object to cleanODS/pilot. This can damage ODS/pilot unit. POSSIBLE CAUSE 1. Ign...
Page 18 - OBSERVED PROBLEM; nance, page 20) or replace burner orifice
18 105192 UNVENTED PROPANE/LP GAS LOG HEATER TROUBLESHOOTING Continued OBSERVED PROBLEM Burner does not light after ODS/pilot is lit Delayed ignition burner Burner backfiring during combustion Slight smoke or odor during initial operation Heater produces a whistling noise whenburner is lit White pow...
Page 19 - IMPORTANT
19 105192 OWNER’S MANUAL TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply.• Do not try to light any appliance.• Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s ...
Page 20 - WARNING: Turn off heater; LOGS; • If you remove logs for cleaning, refer to; MAIN BURNER; SERVICE HINTS; When Gas Pressure Is Too Low; • pilot will not stay lit; Figure 24 - Pilot Inlet Air Hole
20 105192 UNVENTED PROPANE/LP GAS LOG HEATER CLEANING ANDMAINTENANCE WARNING: Turn off heater and let cool before cleaning. CAUTION: You must keep control areas, burner, and circu-lating air passageways of heaterclean. Inspect these areas ofheater before each use. Haveheater inspected yearly by a qu...
Page 21 - PARTS UNDER WARRANTY; SPECIFICATIONS; FIREPLACE HOODS
21 105192 OWNER’S MANUAL REPLACEMENTPARTS Note: Use only original replacement parts. This will protect your warranty coverage forparts replaced under warranty. PARTS UNDER WARRANTY Contact authorized dealers of this product.If they can’t supply original replacementp a r t ( s ) , c a l l F i r e p l...
Page 22 - ODS Pilot
22 105192 UNVENTED PROPANE/LP GAS LOG HEATER ILLUSTRATEDPARTSBREAKDOWN HEAT MAJIC™FVF18PFVF24PFVF30P ODS Pilot 4 12 21 10 11 21 7 21 5 6 8 9 15 14 16 19 2 18 13 19 17 20 18 3 1
Page 23 - PARTS LIST; KEY
23 105192 OWNER’S MANUAL PARTS LIST FVF18PFVF24PFVF30P This list contains replaceable parts used in your heater. When ordering parts, follow theinstructions listed under Replacement Parts on page 21 of this manual. KEY PART NUMBER FOR NO. FVF18P FVF24P FVF30P DESCRIPTION QTY 1 105186-01 105186-02 10...
Page 24 - KEEP THIS WARRANTY; WARRANTY INFORMATION; Model; NOT A UPC; LIMITED WARRANTY
KEEP THIS WARRANTY WARRANTY INFORMATION Always specify model and serial numbers when communicating with the factory. We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty.We make no other warranty, expressed or im...