- Page 2 – UNVENTED PROPANE/LP GAS LOG HEATER; DANGER: Carbon monoxide; WARNINGS; WARNING: Any change to this; Carbon Monoxide Poisoning:; WARNING: Do not allow fans
- Page 3 – OWNER’S MANUAL; LOCAL CODES; OPERATION; UNPACKING; Figure 1 - Heat MajicTM Log Set; CAUTION: Do not remove the; Continued
- Page 4 – Unusually Tight Construction; per kw) of the aggregate input
- Page 5 – DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION; Determining if You Have a Confined or Unconfined Space
- Page 6 – Ventilation Air From Outdoors; Do not provide openings for; Figure 3 - Ventilation Air from Outdoors
- Page 7 – LOG SIZING REQUIREMENTS; INSTALLATION; CHECK GAS TYPE; A. Clearances from the side of the fireplace
- Page 8 – If using a mantel, proceed to If Using
- Page 9 – Figure 7 - Minimum Mantel Clearances When Using Hood; Figure 6 - Minimum Mantel Clearances Without Using Hood; MANTEL CLEARANCES; flue damper open; FLOOR CLEARANCES; A. If installing appliance on the floor level,
- Page 10 – You prefer vented operation; Figure 10 - Attaching Damper Clamp; Make sure the heater burner; Masonry Fireplace
- Page 11 – Figure 12 - Attaching Base Assembly to Fireplace Floor; Figure 11 - Attaching Flexible Gas Hose to Heater Gas Regulator; Installation Items Needed
- Page 12 – Figure 14 - Gas Connection; CAUTION: Avoid damage to; WARNING: Never connect
- Page 13 – Figure 15 - Equipment Shutoff Valve; Figure 16 - Checking Gas Joints; Correct all leaks at once.; WARNING: Never use an open
- Page 14 – WARNING: Failure to position; INSTALLING LOGS; Make sure log does not; CAUTION: After installation
- Page 15 – FOR YOUR SAFETY; Figure 19 - Control Knob and Ignitor Button Location; LIGHTING; • If fireplace has glass doors,
- Page 16 – Appearance of pilot; Figure 21 - Correct Pilot Flame Pattern; Figure 22 - Incorrect Pilot Flame Pattern; Shutting Off Heater; WARNING: Do not operate
- Page 17 – TROUBLESHOOTING; POSSIBLE CAUSE; All troubleshooting items are listed in
- Page 18 – OBSERVED PROBLEM; nance, page 20) or replace burner orifice
- Page 19 – IMPORTANT
- Page 20 – WARNING: Turn off heater; LOGS; • If you remove logs for cleaning, refer to; MAIN BURNER; SERVICE HINTS; When Gas Pressure Is Too Low; • pilot will not stay lit; Figure 24 - Pilot Inlet Air Hole
- Page 21 – PARTS UNDER WARRANTY; SPECIFICATIONS; FIREPLACE HOODS
- Page 22 – ODS Pilot
- Page 23 – PARTS LIST; KEY
- Page 24 – KEEP THIS WARRANTY; WARRANTY INFORMATION; Model; NOT A UPC; LIMITED WARRANTY
Save this manual for future reference.
UNVENTED (VENT-FREE)
PROPANE/LP GAS LOG HEATER
ALSO DESIGN-CERTIFIED AS A VENTED DECORATIVE APPLIANCE
OWNER’S OPERATION AND INSTALLATION MANUAL
18", 24" and 30" Variable
Manually-Controlled Models
Patent Pending
Heat Majic™
Models FVF18P,
FVF24P, and
FVF30P
WARNING: If the information in this manual is
not followed exactly, a fire or explosion may
result causing property damage, personal in-
jury, or loss of life.
— Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do
not use any phone in your building.
• Immediately call your gas supplier
from a neighbor’s phone. Follow the
gas supplier’s instructions.
• If you cannot reach your gas supplier,
call the fire department.
— Installation and service must be per-
formed by a qualified installer, service
agency, or the gas supplier.
WARNING: Improper installation, adjust-
ment, alteration, service, or maintenance
can cause injury or property damage.
Refer to this manual for correct installa-
tion and operational procedures. For as-
sistance or additional information con-
sult a qualified installer, service agency,
or the gas supplier.
WARNING: This appliance is for installa-
tion only in a solid-fuel burning masonry
or UL127 factory-built fireplace, or in an
approved ventless firebox. It is design
certified for these installations in accor-
dance with ANSI Z21.11.2. Exception: Do
not install this appliance in a factory-built
fireplace that includes instructions stat-
ing it has not been tested or should not be
used with unvented gas logs.
WARNING: This is an unvented gas-fired heater. It uses air (oxygen) from the room in which
it is installed. Provisions for adequate combustion and ventilation air must be provided. Refer
to
Air for Combustion and Ventilation section on page 4 of this manual.
This appliance may be installed in an aftermarket*, permanently located, manufactured (mo-
bile) home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This
appliance is not convertible for use with other gases.
* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 105192 UNVENTED PROPANE/LP GAS LOG HEATER SAFETYINFORMATION DANGER: Carbon monoxide poisoning may lead to death! WARNING ICON G 001 WARNINGS IMPORTANT: Read this owner’smanual carefully and completelybefore trying to assemble, oper-ate, or service this heater. Im-proper use of this heater cancause...
3 105192 OWNER’S MANUAL LOCAL CODES Install and use heater with care. Follow alllocal codes. In the absence of local codes, usethe latest edition of The National Fuel GasCode ANSI Z223.1/NFPA 54*. *Available from: American National Standards Institute, Inc. 1430 Broadway New York, NY 10018 National ...
4 105192 UNVENTED PROPANE/LP GAS LOG HEATER AIR FORCOMBUSTION ANDVENTILATION PROVIDING ADEQUATEVENTILATION The following are excerpts from Na-tional Fuel Gas Code , ANSI Z223.1/NFPA 54, Section 5.3, Air for Combus-tion and Ventilation. All spaces in homes fall into one of the threefollowing ventilat...