FMI SVYD18PRA - Manual
FMI SVYD18PRA – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – SAFETY; Air for Combustion; chemicals known to the state; TABLE OF CONTENTS
- Page 3 – this heater or its controls can; Continued; and adults away from hot surface
- Page 4 – Figure 1 - Typical Stove Cabinet Model with Gas Log Heater; PRODUCT IDENTIFICATION
- Page 5 – The National Fuel; State of Massachusetts:; PRODUCT FEATURES; OPERATION; WARNING: This heater shall; National Fuel Gas; the; International Fuel Gas Code,; or; National Fuel
- Page 6 – and; you must provide additional fresh air. See; AIR FOR COMBUSTION AND VENTILATION
- Page 7 – WARNING: If the area in which; National Fuel; VENTILATION AIR; Ventilation Air From Inside Building; National Fuel Gas Code, ANSI; Ventilation Air From Outdoors; Provide extra fresh air by using ventilation; Figure 3 - Ventilation Air from Outdoors
- Page 8 – INSTALLATION; Air for Combustion and Ventila-; CHECK GAS TYPE
- Page 9 – Figure 4 - Minimum Clearance to Walls; Figure 5 - Unpacking Stove from Wooden; STOVE BACK; UNPACKING
- Page 10 – CAUTION: Do not remove the; INSTALLING GAS LOG INTO STOVE; Log will fit securely on base.; With the heater set to HI, check; Figure 7 - Top View of One-Piece Log Set; CONNECTING TO GAS SUPPLY; CAUTION: Never connect
- Page 11 – WARNING: Never connect; Installation Items Needed; Figure 8 - Gas Regulator Location and; Back View; Figure 9 - External Regulator With Vent
- Page 12 – Figure 10 - Gas Connection; CHECKING GAS CONNECTIONS; and connections, internal and; necting to Gas Supply; Figure 11 - Equipment Shutoff Valve
- Page 13 – Figure 12 - Checking Gas Joints; INSTALLING ROD AND SCREEN
- Page 14 – FOR YOUR SAFETY; low these instructions exactly,; WHAT TO DO IF YOU SMELL GAS; LIGHTING; come on automatically within
- Page 15 – Note: AUTO is only functional; WARNING: Make sure the; TO TURN OFF GAS; Shutting Off Heater; MANUAL LIGHTING; Figure 16 - Control Knob and Ignitor; REMOTE OPERATION; Lighting
- Page 16 – in ON Position; INSPECTING BURNERS; BURNER PRIMARY AIR HOLES; turn off heater and let cool. Remove blockage.; PILOT FLAME PATTERN; To Turn Off Gas to Ap-
- Page 17 – CLEANING AND MAINTENANCE; Figure 22 - Pilot Inlet Air Hole; WARNING: Turn off heater; BURNER INjECTOR HOLDER AND
- Page 18 – TROUBLESHOOTING; WARNING: Turn off heater and let cool before servicing. Only a; Note: All troubleshooting items are listed in order of operation.; POSSIBLE CAUSE; Cleaning; OBSERVED PROBLEM
- Page 20 – TANT; REMEDY; nections
- Page 21 – SPECIFICATIONS; WIRING DIAGRAM; Contact authorized dealers of this product.; TECHNICAL SERVICE; You can also visit our web site at; SERVICE HINTS; When Gas Pressure Is Too Low
- Page 22 – PARTS; MODELS SVYD18PRA AND SVYD18NRA
- Page 23 – Replacement Parts
- Page 24 – ACCESSORIES; RECEIVER AND HAND-HELD; Allows the gas; CAST IRON STOVE BODY; CISB
- Page 25 – NOTES
- Page 28 – WARRANTY; KEEP THIS WARRANTY; FMI PRODUCTS, LLC LIMITED WARRANTIES; located on product or identification tag
For more information, visit www.fmiproducts.com
WARNING: If the information in this manual is not
followed exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.
— Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Immediately call your gas supplier from a neighbor’s
phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire
department.
— Installation and service must be performed by a quali
-
fied installer, service agency or the gas supplier.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
UNVENTED (VENT-FREE) GAS STOVE HEATER
OWNER’S OPERATION AND INSTALLATION MANUAL
MODELS SVYD18NRA AND SVYD18PRA
REMOTE-READY CONTROL GAS LOG HEATER
(BURNER SYSTEM FOR CAST IRON STOVES)
I M P O R TA N T: T h i s b u r n e r s y s
-
tem must be installed into approved
FMI PRODUCTS, LLC cast iron stove
bodies, models CISB, CISNI, CISAW or
CISAS only.
PFS
®
US
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
www.fmiproducts.com 113084-01L 2 SAFETY W A R N I N G : T h e SVYD18NRA/PRA series vent-free gas log heater is only approved for use in the CISB, CISNI, CISAW, or CISAS cast iron stove models. (* Indicates Color Suffix Designation) WARNING: Improper installation, adjustment, alteration, service or m...
www.fmiproducts.com 113084-01L 3 Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced. Some people are more affected by c...
www.fmiproducts.com 113084-01L 4 6. Do not add extra logs or ornaments such as pine cones, vermiculite or rock wool. Using these added items can cause sooting. 7. This log heater is designed to be smoke- less. If logs ever appear to smoke, turn off heater and call a qualified service person. Note: D...