Page 2 - TABLE OF CONTENTS; OSD
- 2 - TABLE OF CONTENTS 1. PRODUCT OVERVIEW ........................................................................................................................... 3 1.1 M AIN F EATURES .................................................................................................................
Page 4 - Package Contents; OPTIONAL ACCESSORIES
- 4 - 1.2 Package Contents z Camera Unit x 1 z Mounting Accessory includes: - Screws x 4 - Expanding Screws x 4 - Wrench x 1 z Weather-proof Conduit x 1 z Extension Power Cable and Video cable x 1 z Extension Power Cable x 1 z Desiccant Pack x 1 z Manual x 1 OPTIONAL ACCESSORIES z Wall Mount Bracket...
Page 7 - Hardware Overview
- 7 - 1.5 Hardware Overview Conduit plug setscrew Side conduit hole Back conduit hole Mounting Setscrew Mounting Setscrew Mounting Setscrew Mounting Setscrew OSD mini-joystick Controller Camera Module
Page 8 - Detail Installation Steps:; Figure 1; Locking Screws; Figure 2
- 8 - 2. INSTALLATION This section covers simple steps and detail installation. Please follow instruction for preventing any unnecessary damage. Simple Steps: 1. Open camera cover. 2. Rotate camera if install on ceiling 3. Drill holes on wall/ceiling. Mount cameras. 4. Connect power and video. 5. Op...
Page 9 - Instruction for rotating the camera mounting; Please unscrew fixing screws that hold the camera module.
- 9 - To remove the camera, first unplug the wire connection on the back of the camera. Then loosen the 2 locking screws on the camera base, push the camera base to the right (toward heater direction, as shown in Figure 2), remove the camera from the mounting base. Reinstall the camera and the cable...
Page 10 - Mounting Cameras on the Ceiling/Wall
- 10 - d. Tighten fixing screws and finished 2.2 Mounting Cameras on the Ceiling/Wall a. Mount the base to the wall or ceiling, fix the base by the 4 screws in the accessory pack.(see dimension b for drilling dimension). This dome is weighted 1.7kg, please make sure if the mounting is strengthened e...
Page 11 - Conduit cable and Connect Power and Video; conduit in the bag and wire power connection cable through it.; Conduit plug
- 11 - b. Take off cable conduit if you need to wire cable through side conduit hole. The camera comes with a conduit plug pre-installed in the PF 1/2 conduit hole on the side. The conduit plug can be removed and installed in the back conduit hole (as shown in Figure 5) 2.3 Conduit cable and Connect...
Page 12 - Figure 7
- 12 - b. Connect cable conduit to the conduit hole and make it tight. c. Connect the power supply cable (24VAC), video output to the proper connectors. The extension power has 4 colors for Power +(red), - (white) and Video(yellow), GND(black ). Please match the colors with terminal board shown as F...
Page 13 - V. Phase adjustment screw; is located on the termination board. The vertical phase; Micro Switch for Alarm trigger
- 13 - e. Optional connect to Alarm(Please see figure 8 for terminal functions) f. V. Phase adjustment screw is located on the termination board. The vertical phase may require adjustment to synchronize the vertical phase of the camera with other camera in the system when it is to be used in the lin...
Page 14 - Adjust Lens zoom and focus and View; Adjust view angle; Zoom
- 14 - 2.4 Adjust Lens zoom and focus and View a. Adjust Lens zoom and focus(for vari-focal lens models) b. Adjust view angle The camera can be rotated 360 ° horizontally, 140 ° vertically and 60 ° 3’rd axis view angles (as shown in Figure 11). Adjust the proper camera view angle as needed. Figure 1...
Page 18 - : Press SET button and you can return to the previous page.; : Press SET button and you can return to the previous page.
- 18 - ID POSITION: UP-LEFT / UP-CENTER / UP-RIGHT / DWN-LEFT / DWN-CENTER / DWN-RIGHT There are four positions can be chosen to show the CAMERA ID on the screen. Choose an ID position that will not cover the import/critical part of images. PREVIOUS PAGE : Press SET button and you can return to the ...
Page 22 - Internal; SYNC – LINELOCK
- 22 - 4.7 SYNC SYNC: INTERNAL/LINELOCK SYNC-INTERNAL Internal synchronization. SYNC – LINELOCK Phase adjustment may be necessary in multiple camera installations to prevent picture roll. V.PHASE: 0~620 SYNC MENU >SYNC INTERNAL PREVIOUS PAGE. LINELOCK MENU >V PHASE ++++++++++++ 0 519 620 PREVI...
Page 24 - you will be asked “Are you sure?” before; SW REV; indicating firmware version.
- 24 - SAVE RESTORE EXIT: RESTORE FACTORY SETTING RESTORE FACTORY SETTING: you will be asked “Are you sure?” before you restore all settings to factory values. Select “YES” to confirm. SW REV : indicating software version. FW REV.: indicating firmware version. PREVIOUS PAGE : Press SET button and yo...
Page 25 - EverFocus Electronics Corp.
- 25 - EverFocus Electronics Corp. Head Office: 12F, No.79 Sec. 1 Shin-Tai Wu Road, Hsi-Chih, Taipei, Taiwan TEL: +886-2-26982334 FAX: +886-2-26982380 www.everfocus.com.tw USA L.A. Office: 1801 Highland Ave. Unit A Duarte, CA 91010, U.S.A. TEL: +1-626-844-8888 FAX: +1-626-844-8838 www.everfocus.com ...