Page 2 - Safety Precautions
2 FOR SAFE INSTALLATION AND OPERATION OF YOUR “ENVIRO” HEATER, PLEASE CAREFULLY READ THE FOLLOWING INFORMATION: • All ENVIRO gas-fired appliances must be installed in accordance with their instructions. Carefully read all the instructions in this manual first. Consult the building authority having j...
Page 3 - Table of Contents
3 Safety Precautions....................................................................................................2Table of Contents......................................................................................................3Codes And Approvals...........................................
Page 4 - Codes And Approvals; IN CANADA
4 DIRECT VENT ONLY: This type is identified by the sufix DV. This appliance draws all of its air for combustion from outside the dwelling, through a specially designed vent pipe system. ** TOP VENT DV ONLY** This appliance has been tested and approved for installations from 0 feet to 4500 feet (1372...
Page 5 - Specifications; inches; Must have hearth pad if installed on a carpeted surface.; If this unit is installed in an alcove the alcove must meet
5 Specifications D IMENSIONS : �� � � �� � �������� �� � � �� � �������� �� �� � �� � �������� �� � � �� � �������� �� � � �� � �������� �� � � �� � �������� �� � � � � �������� �� � � � � �������� �� � � �� � �������� Height: 24 1 / 16 inches (611 mm) Width: 19 1 / 16 inches (484 mm) Depth: 15 5⁄8 ...
Page 6 - Operating Instructions; FOR YOUR SAFETY READ COMPLETELY BEFORE OPERATING.; If not recently done, remove the glass and let the unit air out; Turn on gas to the heater. Leak test all joints; NEVER USE AN OPEN FLAME FOR LEAK TESTING.; the rocker switch to ON. Check that all burner ports have flame.
Operating Instructions FOR YOUR SAFETY READ COMPLETELY BEFORE OPERATING. L IGHTING I NSTRUCTIONS : 6 CAUTION: Hot while oper ating. Do not touch. Keep children, clothing, furnit ure, gasoline or o ther flammable vapors away. FOR YOUR SAFETY: Do not operate this fireplace with the glass removed, crac...
Page 7 - Maintenance And Service; When the fireplace has cooled; , remove the face of the fireplace along with the glass. See; Use a mild glass cleaner and a soft cloth; Depending on the amount of use,; Do not clean the glass; as in the
7 Maintenance And Service R OUTINE M AINTENANCE : At least once a year, run through the following procedures to ensure the system is clean and working properly. Check the burner to see if all the ports are clear and clean. Check the pilot to make sure it is not blocked by anything. The pilot flame s...
Page 8 - replacement is required (see; ). Wear gloves when handling damaged glass door; must; be done by a licensed or; The glass must be purchased from an ENVIRO dealer. No substitute; the tape in a bottom corner. Close door.
8 R EPLACING G LASS : The glass in the fireplace is a high temperature ceramic. If the glass is damaged in any way, a factory replacement is required (see P ARTS L IST - C OMPONENTS ). Wear gloves when handling damaged glass door assembly to prevent personal injury. When the glass door assembly is b...
Page 9 - TO BE INSTALLED BY A QUALIFIED SERVICE AGENCY ONLY; on how to remove and install the HI/LO regulator.
Maintenance And Service TO BE INSTALLED BY A QUALIFIED SERVICE AGENCY ONLY F UEL C ONVERSION : Warning: This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdicti...
Page 10 - NOTE: Venting terminals shall not be recessed into walls or siding.; Initial Installation; QUALIFIED INSTALLERS ONLY; D E
10 1 In accordance with the current CSA B149, Natural Gas and Propane Installation Code. 2 In accordance with the current ANSI Z223.1 NFPA 54, National Fuel Gas Code. * These numbers are only estimates. Clearance in accordance with installation codes and the requirements of the gas supplier. t A ven...
Page 11 - FOR THE VENT TERMINATION CAN BE ACCOMMODATED.; FOLLOW THE VENT LENGTH DIAGRAM
11 Initial Installation V ENT P ARTS : This fireplace have been tested and certified for use with SIMPSON DURAVENT TYPE GS PIPE FOR GAS STOVES. SELKIRK DIRECT-TEMP SYSTEM SECURITY CHIMNEY’S “SECURE VENT DIRECT VENT SYSTEM” and SELKIRK “METALBESTOS MDV VENT SYSTEM” kits are available for horizontal v...
Page 15 - black
15 cap assembly. It is important that the vent pipe extend into the vent cap a sufficient distance with a minimum of 11⁄4” (3.2 cm) overlap. Secure the connection between the vent cap pipe and the vent cap by attaching the two sheet metal straps extending from the vent cap assembly into the outer wa...
Page 16 - should have a 1⁄4 inch rise
Initial Installation 24" (610mm) Maximum Horizontal 24" (610mm) Minimum Vertical Inside Finished Collar Wall Thimble Horizontal Vent Termination Exterior Wall Surface Insulation Interior Wall Surface If installed on a carpeted surface a hearth is required Interior Wall Surface 2.5" (64mm...
Page 17 - STEP 4
17 STEP 4 . Assemble the desired lengths of black pipe and elbows necessary to reach from the appliance adapter up through the Round Support Box. Insure that all pipe and elbow connections are in their fully twist-locked position. STEP 5. Cut hole in the roof centered on the small hole placed in the...
Page 18 - support straps that extend out beyond the edge of the flashing.; Roof Pitch; the flashing and the roof. Insure the roofing
Initial Installation QUALIFIED INSTALLERS ONLY Vertical Termination Storm Collar Flashing Roofing nails Elbow Strap STEP 6. Once the pipe sections have been joined, and run up through the hole in the roof, slip an elbow strap over the exposed sections, bend the support straps outwards, and push the ...
Page 21 - AUTOMATIC SAFETY SHUT DOWN:
21 Initial Installation 4. After a minimum of 10 minutes operation, test the chimney draft with a smoke match at the top row of the pattern to confirm that there is adequate draft or ‘pull’ at the openings around the body of the Drafthood Adaptor, as shown in Figure 26. AUTOMATIC SAFETY SHUT DOWN: I...
Page 23 - Always check for gas leaks with a soap
23 Initial Installation G AS L INE C ONNECTION AND T ESTING : WARNING: Only persons licensed to work with gas piping may make the necessary gas connections to this appliance. GAS LINE CONNECTION • This stove is equipped with a certified flexible pipe located on the right side of the unit terminating...
Page 25 - Secondary Installation; NOTE: The logs are fragile and
25 Secondary Installation I NSTALLATION OF L OG S ET AND E MBERS : The placement of the logs is not arbitrary. If they are positioned incorrectly, the flames can be “pinched” and will not burn correctly. The burner come with four (4) locator pins (see Figure 32), and the bottom logs have ledges whic...
Page 26 - CAUTION: NEVER OPERATE THIS APPLIANCE WITH THE DOOR REMOVED.; ALL
26 Secondary Installation CAUTION: NEVER OPERATE THIS APPLIANCE WITH THE DOOR REMOVED. Important note: When the unit is turned on for the first time, It should be turned onto high without the fan on for the first 4 hours. This will cure the paint, logs, gasket material and the other products used in...
Page 27 - Trouble Shooting; Problem
27 Trouble Shooting Problem Possible Cause Solution Spark will not light the pilot after repeatedly pressing the spark ignitor Defective piezo ignitor. • Check connections to ignitor. • If ignitor connections are good but no spark, replace ignitor. Broken spark electrode. • Check for broken ceramic ...
Page 28 - Parts List; Reference
28 Parts List Reference Number Description Part Number 1 120°F (49°C) Ceramic Fan Temperature Sensor EC-001 2 S.I.T. Nova Valve NG (50% turn down) EC-006 2 S.I.T. Nova Valve LP (50% turn down) EC-007 3 Thermocouple EC-009 Spark Electrode with Ignitor Cable EC-011 3 Thermopile EC-012 3 Pilot Orifice ...
Page 31 - Parts Diagram; SC
31 Parts Diagram A SC O T -C om po ne nt s D ec em be r2 00 4 �� �� �� �� �� � �� � �� � �� �� �� � � � �� � �� �� � �
Page 32 - Warranty; AN OFFICIAL WARRANTY CLAIM FORM:
Warranty Sherwood Industries Ltd. offers a Limited Lifetime Warranty on this gas product. This limited lifetime warranty covers the appliance for a period of seven years from the date of installation. This warranty applies only to the original owner in the original location Covered under the lifetim...
Page 33 - Installation Data Sheet; INSTALLER’S SIGNATURE:
33 Installation Data Sheet The following information must be recorded by the installer for warranty purposes and future reference. NAME OF OWNER: _________________________________________ ADDRESS: _________________________________________ _________________________________________ ___________________...